background image

No.2:RUG-007/011/053 No.3:RUG-008/009/054

No.2 and No.3 Steel Rugby Posts

INS631

Revision 5

©

08/09/2015

Harrod UK Limited

Code:

Product:

Important Note for RUG-053 & RUG-054

If RUG-053 or RUG-054 have been purchased
for adapting an existing set of rugby posts, you
will need to cut down your existing uprights as
follows:
For sockets installed 25mm below ground level
the distance from the underside of the channel to
the bottom of the upright needs to be 2925mm.
For sockets flush with ground level this needs to
be 2900mm.

IMPORTANT

: Please read the assembly instructions

carefully before starting to assemble you posts

Pack Contents:

4

5

1

3

View of Product

Fig 1

1.2m

1m

1.2m

Safety Notes

1
2

4

A risk assessment must be carried out on the
erection of Hinged Rugby and Rugby Adaptors.

Always use mechanical assistance if the Risk
Assessment highlights this requirement.

Always check fasteners before use and tighten
where necessary.

Periodically apply grease to hinge fixing bolts to
pre-long the life the posts.

Posts should always be taken down if strong
winds are forecast.

Post Protectors must be used with all Hinged
Rugby Posts to cover the hinge arrangement.

3

6

5

2

No2 Only

No2 Steel Rugby Posts

RUG-053 No2 Hinge Adaptor Only

No3 Steel Rugby Posts

RUG-054 No3 Hinge Adaptor Only

1. 4 x FEP211

Hinge Assembly

1. 4 x FEP211

Hinge Assembly

1. 4 x FEP223

Hinge Assembly

2. 4 x FEQ666

Upright

2. 4 x RUG-100 Upright
3. 1 x RUG-101 Pair of Crossbars
4. 4 x RUG-102 Ground Socket

1. 4 x FEP223

Hinge Assembly

(RUG-011 only)

(RUG-009 only)
(RUG-009)
(RUG-008)

2. 4 x FEQ664

Bottom Upright

2. 4 x RUG-105 Bottom Upright
3. 1 x RUG-101 Pair of Crossbars
4. 4 x RUG-107 Ground Socket
5. 4 x RUG-106 Top Upright

(RUG-011)
(RUG-007)

Tools Required

1 x 22mm Spanner
2 x 19mm Spanners
2 x 17mm Spanners
1 x Spirit Level
1 x Tape Measure
2 x Step Ladders

Summary of Contents for RUG-007

Page 1: ...ical assistance if the Risk Assessmenthighlightsthisrequirement Always check fasteners before use and tighten wherenecessary Periodically apply grease to hinge fixing bolts to pre longthelifetheposts Posts should always be taken down if strong winds areforecast Post Protectors must be used with all Hinged RugbyPosts tocoverthehingearrangement 3 6 5 2 No2 Only No2 Steel Rugby Posts RUG 053 No2 Hing...

Page 2: ... inFig3a Dig holes 1 2x1 2x1 1m deep at centres of 5 mm as shown in Fig 2 Concrete the sockets in leav approx 0mm from top of concrete to ground level to replace turf Use a spirit level to make sure that the sockets are truly vertical and support until set Replace the turf extracted when the concrete has cured allow concrete to set before moving on to step 2 Note minimumconcreterequired1 2x1 2x1m ...

Page 3: ...t one at a time into the vertical position and for non hinging posts slide the bottom upright into the Socket For hinging posts slide the Safety Bolt with through the hinge assembly and secure with the Nylock Nut as shown in Fig 5 Finally bolt the hinge plates together with the 4 M14 bolts and Washers as shown in Fig 6 Repeatfortheotherpost Using a step ladder at each post lift the crossbar into p...

Page 4: ...ts will fit up to a 76mm square bar A minimum of two people should always oversee the safe erection or dismantling of the rugby posts Never allow the tractor s speed to exceed walking pace we recommend that the tractor moves no faster than 3mph The Hinged Post Assembly Roller is manufactured from steel and fitted with a rubber roller a quick release webbed safety strap and two U bolt brackets The ...

Page 5: ...ht is still acheived Harrod UK offer a range of hinged adaptors to suit many types of uprights Hinge Adaptors for No 1 Steel Rugby Posts 124 00 kg per set Hinge Adapters for Aluminium Rugby Posts 87 50 kg per set Hinge Adaptors for No 2a Steel Rugby Posts 44 00 kg per set Hinged Adaptor Visual Diagram RUG 051 Hinge Adaptors for No 3 Steel Rugby Posts 34 00 kg per set Hinge Adaptors for Heavy Duty ...