HD Link Installation & Operation Manual
4 – Front Panel Configuration & Operation
Version 2, April 2010
4-42
Harris Corporation
Intraplex Products
Aux 2:
Press the up or down arrow (
) to navigate to the
Aux 2
row (Figure 4-66) and then press
the left or right arrow (
) to
select a parameter field to change on the
Aux 2
row:
ON
or
OFF
●
Data
Rate
-
HRS
or
APT
User IP:
Press the up or down arrow (
) to navigate to the
User IP
row (Figure 4-66) and then
press the up or down arrow (
)
to change the
User IP
to
None
(off) or one of these rates:
●
128 kbps
●
256 kbps
●
320 kbps
●
384 kbps
●
512 kbps
●
536 kbps
●
768 kbps
●
1024 kbps
●
1536 kbps
Modulation:
Shows the current modulation.
Min Rx Sgnl Rqrd:
Shows the minimum required signal for the receiver.
Coding Rate:
Shows the current coding rate.
Back:
Select this command and press Enter to return to the previous screen.
Apply:
Select this command and press Enter to save and apply your changes.
Note:
After setting parameters on this screen, you must select
Apply
and press Enter for the
changes to take effect.
Color Codes: White = currently applied value; yellow = value changed but not saved or applied.
4.1.6.4 Service Sync (Receiver Only)
Select
Service Sync
on the
Service Setup
screen to access the
Service Sync
screen (Figure 4-67).
Figure 4-67. Service Setup
Service Sync
The Service Sync function allows the transmitter to send configuration-related information over a slow
in-band control channel, such as:
●
Audio channel parameters
•
On or off
•
Sampling rate
•
Word length
•
Stereo or mono mode
●
Auxiliary audio channel state – On or off
●
LAN port IP address for return path tunneling