HD Link Installation & Operation Manual
4 – Front Panel Configuration & Operation
Version 2, April 2010
4-38
Harris Corporation
Intraplex Products
Figure 4-60. RF Profile
Bandwidth
Press these buttons on the display to configure the bandwidth in kilohertz:
•
Press
to change the bandwidth value.
•
Press Enter to keep changes until you can
Apply
them on the previous screen.
•
Press Cancel to erase your changes and return to the previous value.
You can set
Bandwidth
to
200 KHz
,
250 KHz
,
300 KHz
,
375 KHz
, or
500 KHz
.
Color Codes: White = currently applied value; yellow = value changed but not saved or applied.
Cancel: Press this button to return to the previous screen.
Note:
If you make any changes to this screen, you must select
Apply
and press Enter on the
previous screen to save and apply changes.
Max Modulation Order
Select
Max Modulation Order
on the
RF Profile
front panel screen to access the
Max
Modulation Order
configuration screen (Figure 4-61) and set the limit of QAM the system is to
use.
Figure 4-61. RF Profile
Max Modulation Order
Press these buttons on the display to configure the bandwidth in kilohertz:
•
Press
to change the bandwidth value.
•
Press Enter to keep changes until you can
Apply
them on the previous screen.
•
Press Cancel to erase your changes and return to the previous value.
You can set
Max Modulation Order
values to
QAM 16
,
QAM 32
,
QAM 64
,
QAM 128
,
QAM
256
, or any modulation.
Color Codes: White = currently applied value; yellow = value changed but not saved or applied.
Cancel: Press this button to return to the previous screen.
Note:
If you make any changes to this screen, you must select
Apply
and press Enter on the
previous screen to save and apply changes.