6-8
888-2587-001
4/18/11
WARNING: Disconnect primary power prior to servicing.
FM HD Radio System
Section 6 Troubleshooting
Flexstar Frequency:
Current frequency of HDx-FM exciter. This is information
obtained via the CAN bus from the HDx-FM exciter.
Check Exciter
Flexstar Sum Fault:
(OK/FAULT) FAULT if there is a fault condition in the exciter.
This information is obtained via the CAN bus from the Flexstar exciter.
Check Excitery
Exciter Ready:
(YES/NO) Status of operational state of exciter. This information is
obtained via the CAN bus from the Flexstar exciter.
Check Exciter
AFC Intlk Status:
(OK/FAULT) FAULT if the PLL cannot lock in the exciter. This
information is obtained via the CAN bus from the Flexstar exciter.
Check Exciter
CAN Bus Connection:
(OK/LOSS) If there is no CAN communication a LOSS will be
indicated. This information is obtained via the CAN bus from the Flexstar exciter.
Check cable and connectors. Verify all CAN addresses (ID)s in circuit are correct.
(e) Reset Defaults
: Typing
e
will change all settings back to factory presets.
(f) Fault Reset:
Typing
f
will reset the Fault Strike Status.
(t) Build in Test (IO):
FACTORY USE ONLY - This is a test run in the factory to make
sure all the communications are working correctly. NOTE: This test is intended to be
run with a test fixture.
The voltages displayed in the upper right side of the VT100 screen are samples of the
voltages present on the controller board.
VSWR foldback:
(0-4095) Reference value indicating the current VSWR foldback
level.
MAX power foldback:
(0-4095) Reference value indicating the maximum foldback
power level allowed.
EXT APC Gain[FM]:
(0-4095) Reference value indicating the gain of the external
APC voltage when the Boost Amp is in FM mode.
EXT APC Gain[FM-HD]:
(0-4095) Reference value indicating the gain of the
external APC voltage when the Boost Amp is in FM-HD mode.
EXT APC Gain[HD]:
(0-4095) Reference value indicating the gain of the external
APC voltage when the Boost Amp is in HD mode.
EXT APC Gain[SLC]:
(0-4095) Reference value indicating the gain of the external
APC voltage when the Boost Amp is in SLC mode.
6.4.3
VT100 - Page 2
Configuration and Setting / Faults.
Each line of the VT100 screen is listed below. The
parameter in bold, followed by possible statuses in parenthesis.