APM6800
+
/APM6801
+
Installation and Operation Manual
91
Copyright © 2008-2009, Harris Corporation
Appendix A: Communication and Control Troubleshooting Tips
Hardware Communication Problems
After a power failure, the frames and PC do not communicate.
Solution
1. Wait four minutes for the frames to recover from the power failure.
2. Close the CCS software, and then restart the PC.
3. Restart the software application.
The module does not seem to work.
Solutions
•
Ensure the correct frame is powered up.
•
Verify that all appropriate rear connections are secure.
•
Gently push the module into its slot in the frame to ensure it is seated
properly.
•
Ensure the back module does not have bent pins by following this
procedure:
a.
Unplug the front module.
b. Unscrew and remove the back module.
c.
Inspect the spring connector at the bottom of the back module
(
), and verify the connector does not have any slightly bent
or pressed pins.
d. Carefully reposition any bent pins; if this is not possible, contact
Customer Support.