ACO6800
+
Installation and Operation Manual
19
Copyright © 2009, Harris Corporation
Chapter 3: Configuration and Operation
3. Rotate the hex switch to the parameter number (1 to 9) or letter (A to F) of
the option you want to set.
4. Toggle the navigation switch to select and set the value of the chosen
parameter.
5. Do either of the following:
•
Rotate the hex switch to another parameter number/letter in the current
bank, and then repeat step 4.
•
Rotate the hex switch to “0” again to select a different bank, and then
repeat steps 3 and 4.
Throughout this chapter, in the Parameter Navigation sections, the bank and hex
switch positions for each configuration setting are listed in square brackets (for
example, [
0
,
2
]) beside or below the parameter name.
Note
The manufacturer recommends that you use the available 6800
+
software
control options (serial/local or Ethernet/remote) to aid in viewing, setting,
and confirming parameter values.
Activating On-Screen Display
You can use the On-Screen Display (OSD) Monitoring feature to view the
current parameter selections on your output display. This feature makes
configuring the ACO6800
+
using the card-edge controls much easier.
Note
In ACO6800
+
ISD, ACO6800
+
DSD, and ACO6800
+
IDSD modules, OSD is
only displayed on Out A. In ACO6800
+
ISCST, OSD can be displayed on
any one of the four outputs. OSD is not available in ASI mode. OSD is not
available on ACO6800
+
ASID modules.
Table 3-1. Bank Select LEDs
Bank Number
Bank 0 LED
(first top LED)
Bank 1 LED
(second top LED)
Bank 2 LED
(third top LED)
Bank 3 LED
(fourth top LED)
0
Off
Off
Off
Off
1
On
Off
Off
Off
2
Off
On
Off
Off
3
On
On
Off
Off
4
Off
Off
On
Off
5
On
Off
On
Off
6
Off
On
On
Off
7
On
On
On
Off
8
Off
Off
Off
On