background image

 

Boxer Plus Manual, subject to change, October 2012. Harrie Leenders Haardkachels BV 

1-6 

 
 

General instructions and regulations 

 

Use 

 

All local regulations including those referring to national and European standards must be observed when installing 
the appliance. 

 

Ensure there is sufficient ventilation/air supply in the room where the stove is installed. Air extractors such as a 

cooker hood may cause problems due to flue gases escaping from the stove into the room. 

 

The appliance is not suitable for a shared flue system. 

 

The appliance must be installed on a floor having sufficient bearing capacity. 

 

Ensure adequate access for cleaning the appliance, the flue-gas connection and the chimney. 

 

 

Safety instructions 

 

Glass is quite susceptible to breaking and broken glass is quite sharp. Take appropriate measures. 

 

For general safety, we refer to the VCA guidelines. 

 

Note: After installation, ensure there is no inflammable and/or explosion-hazardous material in or on the stove such 
as a spray can, packing material and the like. 

 
 

Safety distances for Boxer Plus 

 

Rear wall: 20cm. Temperature at safety test; 65°C. 

 

Side wall: 40cm. Temperature at safety test; 77°C. 

 
Specifications for Boxer Plus 

 

Nominal power = 10 kWh. 

 

Flue gas mass flow = 8.3 g/s 

 

Appliance weight = 245 kg 

 

Minimum chimney draught = 12 Pa 

 

Flue gas temperature directly over the stove = 263 °C 

 

 

Installation 

 

To secure the warranty, the Boxer Plus must be installed by a properly qualified person employed by a dealer 
recognized by Harrie Leenders Haardkachels. See leenders.nl for a current list of addresses of recognized 
dealers or contact the manufacturer. 

 

The stove is susceptible to scratching. Handle with care. 

 

After installation, check the draught by burning some kindling wood. 

Boxer Plus 

Installation instructions • EN 

Reviews: