Warnings 

 

Improper installation will create an electrical hazard, which could result in serious 
injury. 

 

DO NOT attempt any internal adjustments inside the heater. 

 

Keep your hands and hair clear of the fan blades to avoid injury. 

 

If you are not familiar with your pool filtering system and heater: 

 

Do not attempt to adjust or service without consulting your dealer, professional 
pool or air conditioning contractor. 

 

Read the entire installation and users guide before attempting to use, service or 
adjust the heater or pool filtering system. 

 

Do not connect the power cord to an intermediate point, use an extension cord, or 
connect multiple devices to heat pump, this may cause overheating, fire or electrical 
shock. 

 

Make sure the power plug is free of dirt and insert it securely into the outlet. 
A dirty plug may cause fire or electric shock. 

 

Do not bundle, pull, damage, or modify the power cord, and do not apply heat or 
place heavy objects on it, this may cause fire or electric shock. 

 

Do not turn the breaker OFF/ON or disconnect/connect the power plug during 
operation, this may create sparks, which can cause fire. 

 

Do not expose your body directly to cool air for a prolonged length of time, this could 
be detrimental to your health. 

 

The unit should not be installed, relocated, disassembled, altered or repaired by the 
user. An improperly handled heat pump may cause fire, electric shock, injury of 
water leakage, etc. Consult your dealer. 

 

If the power supply cord is damaged, it must be replaced by the manufacturer or its 
service agent in order to avoid a hazard. 

 

When installing, relocating or servicing the unit, make sure that no substance other 
than the specified refrigerant (R32) enters the refrigerant circuit, any presence of 
foreign substance such as air can cause abnormal pressure rise and may result in 
explosion or injury. 

 

The use of any refrigerant other than that specified for the system will cause 
mechanical failure, system malfunction of unit breakdown. In the worst case, this 
could lead to a serious impediment to securing product safety. 

 

This appliance is not intended for use by persons (including children) with reduced 
physical, sensory or mental capabilities, or lack of experience and knowledge, unless 
they have been given supervision or instruction concerning use of the appliance by a 
person responsible for their safety. 

 

Children should be supervised to ensure that they do not play with the appliance. 

 

The appliance shall be stored in a room without continuously operating ignition 
sources (for example: open flames, an operating gas appliance or an operating 
electric heater). 

 

Do not insert your finger, a stick or other objects into the air inlet or outlet, this may 
cause injury, since the fan inside rotates at high speeds during operation. 

 

In case of an abnormal condition (such as a burning smell), stop the heat pump and 
disconnect the power plug or turn the breaker OFF. A continued operation in the 
abnormal state may cause a malfunction, fire or electric shock. In this case, consult 
your dealer. 

Summary of Contents for Harmo Kubi ZVWX4015

Page 1: ...Imported by Zwembad BVBA Industrieweg 9 3190 Boortmeerbeek Belgi www harmopool eu Swimming pool heat pump Harmo Kubi Model ZVWX4015 ZVWX5010 ZVWX5020 ZVWX5030 Instruction manual...

Page 2: ...7 Configuration 8 Installation of the bypass 9 Electrical wiring 10 Start up procedure 11 Daily use of the heat pump 11 Condensation 11 Guidelines 12 Water chemistry 12 Winter ready 12 Spring start up...

Page 3: ...comply with these recommendations will void warranty The swimming pool heat pump unit heats the swimming pool water and keeps the temperature constant Characteristics Durable the heating exchanger is...

Page 4: ...Controller Digital control Condenser Titanium heat exchanger Compressor Quantity 1 1 1 1 Compressor Rotary Rotary Rotary Rotary Refrigerant R410a R32 R410a R32 R410a R32 R410a R32 Weight refrigerant 7...

Page 5: ...5 Dimensions of the heat pump Model Size mm ZVWX5010 ZVWX5020 ZVWX5030 A 670 G 101 F 250 ZVWX4015...

Page 6: ...ways keep the unit straight up If the unit has been tilted or put on his side allow 24h before starting the unit Location The unit may be installed virtually anywhere outdoors For indoor pools please...

Page 7: ...er 30 meters could roughly be estimated at 0 6kw hour 2000 BTU for every 5 temperature difference between the pool water and the soil surrounding the pipe which translates to an operation time increas...

Page 8: ...8 Configuration Note the above piping connection is only an example for demonstration...

Page 9: ...set correctly your heat pump will deliver its best performance The bypass has to be built as shown below Install the bypass with all 3 valves entirely open Slightly close valve 1 Close valve 3 about...

Page 10: ...eat pump All heat pumps require a single phase connection Grounding the heat pump is required to protect you against electrical shocks caused by an eventual short circuit inside the heat pump The heat...

Page 11: ...the unit and that is switched off when the water flow becomes too low e g when the filter pump is switched of Time Delay the unit is equipped with a built in 3 minute start delay to protect electrical...

Page 12: ...pump A check valve must be installed between the heat pump and the chemical feeder to prevent back siphoning of chemically saturated water into the heat pump where it will damage the components Winte...

Page 13: ...pouring down onto the unit 6 Do not use the heat pump if any part has been under water Immediately call a qualified professional technician to inspect the heat pump and replace any part of the contro...

Page 14: ...setting Press to alter Press SET again to confirm Press M again 9 0 Press SET to enter water pump setting Press to alter Press SET again to confirm Press M again A 40 Press SET to enter return water t...

Page 15: ...ter from 00 G see the Operation Parameter Table o Under parameter setting press or to set data o Please note no motion on the display for 10s the LCD will display water in water out temp under running...

Page 16: ...s M for 5 seconds to check the current status of the unit You can check water in water out temp condenser temp and ambient temp Please note no motion on the display for 10s The LCD will display water...

Page 17: ...technicians 06 Electronic expansion valve mode 0 Manuel 1 AUTO 1 Adjusted by technicians 07 Automatic restarting after power off 0 1 1 record Adjusted by technicians 08 Mode cooling only heat pump aux...

Page 18: ...he unit as a result of the dirty or clogged filter o The area around the unit should be dry clean and well ventilated Clean the side heating exchanger regularly to maintain good heat exchange and to s...

Page 19: ...etc Consult your dealer If the power supply cord is damaged it must be replaced by the manufacturer or its service agent in order to avoid a hazard When installing relocating or servicing the unit ma...

Page 20: ...e The appliance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Be aware that refrigerants...

Page 21: ...her electric appliances or furniture under the heat pump unit Water may drip down from the unit which may cause damage or malfunction o Do not leave the unit on a damaged installation stand the unit m...

Page 22: ...lower vase on it this may cause fire or electric shock o Do not step on or place any object on the unit this may cause injury if you or the object falls down o Dirty filters cause condensation in the...

Page 23: ...p before you do maintenance R32 Leak detector Explosion proof vacuum pump Anti static gloves IMPORTANT On the heat pump you find the ref of the gas used This is the R410 gas or R32 If your heat pump c...

Page 24: ...time freezing protection in winter PP 07 Ambient temp too low The second time freezing protection in winter PP 07 Ambient temp too low Coil sensor failure cooling mode PP 08 The sensor is open or sho...

Page 25: ...25 Wiring diagram Model ZVWX5010 ZVWX5020 ZVWX5030...

Page 26: ...26 Warranty...