Conformance to overseas standards
8
The nameplate values of various models are shown below.
SG/HP
Mode
Item
SHA25Y
11
51
81
101
121
161
(1) Output at point A
W
133
175
203
207
178
127
(2) Voltage at point A
V
101
115
122
125
125
120
(3) Allowable
continuous
current
A
3.0
3.0
3.0
2.9
2.6
2.1
(4) Speed at point A
rpm
141
41
29
24.5
21
15
(5) Frequency at
point A
Hz
129
174
196
206
212
201
(6) Allowable range
temperature
℃
40
(7) Number of phase
-
3
Model
Item
SHA32Y
SHA40Y
11
51
81
101
121
161
51
81
101
121
161
(1) Output at point A
W
240
328
369
373
308
233
487
564
570
560
480
(2) Voltage at point A
V
97
110
114
118
116
115
109
115
115
116
122
(3) Allowable
continuous
current
A
6.0
6.0
6.0
5.7
5.0
4.1
9.0
9.0
9.0
8.8
7.2
(4) Speed at point A
rpm
115
34
23
20
16.5 12.5
29
20.5 16.5
14
12
(5) Frequency at
point A
Hz
105
145
155
168
166
168
123
138
139
141
161
(6) Allowable range
temperature
℃
40
(7) Number of phase
-
3
Model
Item
SHA58Y
SHA65Y
81
101
121
161
81
101
121
161
(1) Output at point A
W
897
948
863
731
964
963
958
802
(2) Voltage at point A
V
99
101
101
107
92
92
96
100
(3) Allowable
continuous
current
A
17.7 17.8 16.4 13.4 22.0 21.9 20.1 16.3
(4) Speed at point A
rpm
12
10
8.5
7.2
10
8
7.4
6.2
(5) Frequency at
point A
Hz
130
135
137
155
108
108
119
133
(6) Allowable range
temperature
℃
40
(7) Number of phase
-
3
Summary of Contents for SHA - Y series
Page 1: ...AC Servo Actuator S H A Y s e r i e s m a n u a l ISO14001 ISO9001...
Page 61: ...1 15 Cable specifications 1 49 1 2 3 4 5 6 7 8 9 10 11 Outlines...
Page 77: ...2 4 Examining operating status 2 15 1 2 3 4 5 6 7 8 9 10 11 Selection guidelines...
Page 92: ...Chapter 5 Appendix A 1 Unit conversion 5 1 A 2 Calculating inertia moment 5 3...
Page 98: ...Calculating moment of inertia 5 6 1 2 3 4 Apx 6 7 8 9 10 11 Appendix...
Page 99: ......
Page 101: ......