Back Panel LEDs
NOTE:
When the device is first powered up, the power light is green and the local light is yellow. If the
device is not configured, the Fault and Activity lights do not indicate anything.
Back Panel LEDs
The back panel contains two LEDs on the main board.
the main board.
Table 2–4: Front Panel LEDs
LED
Color
Description
Power
Yellow
The Power LED is yellow while the device initializes after startup.
Green
The Power LED turns green when the device initialization is
complete and the management interface is enabled and ready.
Fault
Red
The Fault LED lights when the application software detects an alarm.
Local
Yellow
The Local LED lights when the device is operating in local mode.
Tx
Yellow
The Tx LED lights when the device generates an MPEG-2 transport
stream. It blinks slowly when MPEG packets are being transmitted
steadily. It blinks fast or intermittently when the transmission rate is
slow or intermittent.
Table 2–5: Rear Panel Main Board LEDs
LED
Color
Description
Locator
Blue
The Locator LED lights when this device is enabled through NMX
or SAG.
Use the Locator LED to help you identify a specific chassis in a
rack.
Fault
Red
The Fault LED lights when the application software detects an
alarm.
The front panel and back panel Fault LEDs light at the same time.