background image

ProStream

9100 

RELEASE 17.5

Installation Guide

Rev A

Summary of Contents for ProStream 9100

Page 1: ...ProStream 9100 RELEASE 17 5 Installation Guide Rev A...

Page 2: ...Time and the QuickTime logo are trademarks or registered trademarks of Apple Computer Inc used under license therefrom Harmonic software uses version 3 1 5 4 of the FreeImage open source image library...

Page 3: ...NOT LIMITED TO LOST REVENUES PROFITS OR SAVINGS OR THE COST OF SUBSTITUTE GOODS HOWEVER CAUSED UNDER CONTRACT TORT BREACH OF WARRANTY NEGLIGENCE OR OTHERWISE EVEN IF WE WERE ADVISED OF THE POSSIBILIT...

Page 4: ...attention to information that if ignored can adversely affect the performance of your Harmonic product or that can make a procedure needlessly difficult LASER DANGER The Laser symbol and the Danger al...

Page 5: ...14 Back Panel 14 Central Processing Card CPC 15 Power Supply 16 IOM Slots and Cards 16 DVB ASI IOM 17 Quad GbE IOM 18 8VSB Modulation Card 21 Dual GbE IOM 23 Chapter 2 Installing the ProStream 9100 25...

Page 6: ...aintaining the Air Filter 44 Removing and Replacing the Air Filter 45 Fan Tray 46 Removing and Replacing the Fan Tray 46 Power Supply 48 Removing and Replacing the Power Supply 48 Input Output Modules...

Page 7: ...Compliance 72 Product Regulatory Compliance Markings 72 Product Environmental Compliance 74 EU RoHS 74 EU REACH 75 China RoHS 75 Other RoHS and REACH type Regulations 77 Waste Electrical and Electroni...

Page 8: ...t Panel Back Panel Platform Description Harmonic ProStream 9100 is a highly integrated MPEG DVB multiplexer scrambler descrambler and transcoder for multimedia services carried over digital broadcast...

Page 9: ...a via four DVB ASI ports and supports a maximum bitrate of 1 40 Mbps Each port can be configured as an input or output port This card also supports DVB CSA Common Scrambling Algorithm NOTE For further...

Page 10: ...units that have been thoroughly qualified to operate with the ProStream 9100 device Table 1 2 lists power specifications of a fully populated unit together with the Harmonic part numbers for the quali...

Page 11: ...Microsoft Internet Explorer with comprehensive management capabilities System Requirements of Managing PC System requirements of the managing computer vary according to the control mode as described...

Page 12: ...2 3 Table 1 5 ProStream 9100 Front Panel Item Feature 1 Front bezel 2 Ethernet service port for debugging purposes only 3 LEDs 4 Control Panel 5 Front Panel Latch NOTE Cooling fans are mounted on the...

Page 13: ...Local Yellow Local Control indicator 5 LED TX Yellow Transmitting Indicator 6 LCD panel Status indicator 7 Latch Front panel latch 8 Right key Menu right 9 ESC key Menu escape 10 ENTER key Menu Select...

Page 14: ...TION Do not obstruct the airflow when mounting the device on the rack Severe equipment damage can result when the device cannot properly exhaust the airflow Cooling Fans The ProStream 9100 platform us...

Page 15: ...ct the device to the management network The ETH 2 port connects to the CAS network when required ETH1and ETH2 are 10 100 1000 Base T ports For cabling instructions see Connecting the Ethernet Cables E...

Page 16: ...ns see Power Supply Specifications The physical dimensions of the AC DC power supply unit are 40mmH x 90mmW x 440mmD Each power supply unit features two LEDs The following table describes the LEDs For...

Page 17: ...ion applies to both types of the DVB ASI card Each DVB ASI IOM card has four independent ports labeled ASI 1 to ASI 4 Each port can be configured as an input or output port The following table lists A...

Page 18: ...Maximum bitrate is 10 Gbps The ports are labeled 10GbE1to10GbE2 These ports support fiber cables only and use SFP transceivers Table 1 11 Status of ASI Port Rx LEDs Color Description Off Port is disab...

Page 19: ...or fiber 2xGbE 1 Gbps with SFP transceiver for copper cables 2xGbE 10 Gbps Input extraction SFP transceiver for fiber cable only SFP transceiver for either fiber of copper cables Max output bitrate Up...

Page 20: ...erface 1000 Base LX Multi mode optical interface 1000 Base SX Copper interface 1000 Base T SFP relevant only to the Quad GbE IOM Multi mode optical interface 1000 Base SX 1G Ethernet 10GBase SR SW 10G...

Page 21: ...nsport Streams NOTE The four inputs are enabled by optional firmware licenses 8VSB Modulation Card Specifications Table 1 14 provides the specifications for the RF module Table 1 15 1Giga SFP Modules...

Page 22: ...ning Range VHF UHF Channels 2 59 Note The tuning range is limited to Channels 2 to 59 by software and SCTE 02 2006 per the FCC Industry Canada decisions to release channels 60 to 69 for public safety...

Page 23: ...taneously as an input and output port Connector Two receptacles for SFP module Max input bitrate Up to 500 Mbps per card Number of input sockets Up to 256 sockets SPTS or MPTS for both ports Input ext...

Page 24: ...E port features two LEDs Tx and Rx The following table describes the available status of each LED Table 1 20 Status of GbE Port LEDs LED Status Color Description Activity Green On A live fiber is conn...

Page 25: ...For installation and cabling you need the following Phillips screwdriver To mount the ProStream 9100 device in a standard 19 inch rack Rack mount screws Harmonic ships the necessary rack mount screws...

Page 26: ...ervicing The following guidelines are provided to assure your safety This unit should be mounted at the bottom of the rack if it is the only unit in the rack When mounting this unit in a partially fil...

Page 27: ...the rack 1 If necessary place a Tinnerman speed nut with the nut on the outside of the rack over the holes to which you want to mount the rails NOTE Each of the four rack posts requires two speed nuts...

Page 28: ...rt four screws through the mount holes in the front of the device to the corresponding holes on the rack posts 5 Tighten the screws with a screwdriver 6 Carefully replace the front bezel of the device...

Page 29: ...ther before or after mounting the device in the rack according to your personal preference To insert an IOM RF card 1 Verify that the device is powered off 2 Remove the filler panel that covers the re...

Page 30: ...plug the power cable to turn off the device Cabling the ProStream 9100 device is very straightforward All input and output ports as well as Ethernet ports are clearly marked For further information se...

Page 31: ...emale connector of the required ASI port located on the ProStream 9100 back panel 2 Connect the connector on the other side of the cable to your ASI source destination Connecting the GbE Input Output...

Page 32: ...he other side of the cable to your ATSC 8VSB source Grounding Mounted Devices ProStream 9100 is manufactured with zinc plating on all chassis surfaces The unit is installed with metal to metal contact...

Page 33: ...equence begins as described in Local Control Panel Display Messages during Bootup Connecting the AC Power Supply The device AC power supply uses autosensing to adjust to different incoming voltages Th...

Page 34: ...E Overcurrent protection devices must meet applicable national and local electrical safety codes and be approved for the intended application Wiring Requirements The device is connected to the DC powe...

Page 35: ...ble To assemble the DC input power cable 1 Prepare the power wires as specified in Wiring Requirements 2 Use the disconnect device to make sure that the power supply from the DC power source to the ca...

Page 36: ...section of the wire into the matching hole in the DC plug connector as shown in Figure 2 8 Figure 2 8 DC Power Connector Detail 8 Repeat step 5 through step 7 for the other two wires to complete the a...

Page 37: ...ing a system reset and loading new software Messages when Resetting the Device When you reset the device from NMX a message on the VFD shows that the device has been reset The device uses the boot fil...

Page 38: ...itialization is complete and the management interface is enabled and ready Fault Red The Fault LED lights when the application software detects an alarm Local Yellow The Local LED lights when the devi...

Page 39: ...ddress of the device when you add the device to a network group See Front Panel Display for instructions on viewing the MAC address in the front panel display While you can perform all platform and co...

Page 40: ...parameters and options As shown in Figure 3 2 line 1 of the local control panel shows the menu path for the currently selected option To represent a path the VFD displays each submenu as two or more l...

Page 41: ...ion without raising license related alarms A small set of licenses are time limited and have different behavior as follows Streams that include features under license raise alarms when their licensing...

Page 42: ...nding Apply 7 Click Apply Certificate to add the license to the device To remove licenses from your device in NodeLock License Manager 1 Under Device Licenses Revised Quantity enter the new reduced am...

Page 43: ...removed See ESD Guidelines You do not need to unplug the device when removing and replacing the bezel As you go through the steps in the following procedure refer to the corresponding number in Figure...

Page 44: ...uses an air filter to minimize dust and dirt in the circuitry and components in the chassis The filter is made of flexible open cell polyurethane foam which is specially coated to provide flame and f...

Page 45: ...Air Filter You do not need to unplug the device when removing and replacing the air filter NOTE You might need to slide the chassis forward to enable this procedure To remove the air filter 1 Using y...

Page 46: ...curved frame housing the front panel display unit attaches to the front of the fan tray unit and is considered an integral part of the fan tray unit This curved frame must not be removed at any time...

Page 47: ...lease 17 5 Rev A Fan Tray Figure 4 5 Removing the Fan Tray 4 Slide the fan tray assembly away from the chassis To replace the fan tray assembly 1 Replace the fan tray assembly by sliding the tray into...

Page 48: ...supply as outlined in Removing and Replacing the Power Supply Removing and Replacing the Power Supply To remove the power supply 1 Turn off the device by unplugging the power cord 2 Remove the bezel f...

Page 49: ...l handle on the front of the power supply unit and pull firmly to disengage the power supply from the connector as shown in Figure 4 7 step 2 6 Slide the power supply away from the unit To replace the...

Page 50: ...e fan tray assembly as described in Removing and Replacing the Fan Tray 4 Reinstall the bezel as described in Removing and Replacing the Bezel Input Output Modules To extend the capability of the ProS...

Page 51: ...an IOM NOTE The cover must never be removed The illustrated figures show no cover for ease of explanation 2 Pull firmly on the module to remove it from the chassis as shown in Figure 4 9 step 2 To rep...

Page 52: ...n required by the customer Transcoding specifications per ProStream 9100 with ACE are as follows In case you need to install or replace a transcoding module or other IPC handle it according to the fol...

Page 53: ...rmonic Inc All rights reserved 53 ProStream 9100 Release 17 5 Rev A Inserting Replacing IPC Cards Figure 4 11 Removing the Card Retaining Device 5 Grab the card handle to slide the card out of the cha...

Page 54: ...ProStream 9100 Release 17 5 Rev A Inserting Replacing IPC Cards Figure 4 12 Removing an IPC Card To replace an IPC Card 1 From the front of the unit insert the IPC module into the chassis until the mo...

Page 55: ...ream 9100 Release 17 5 Rev A Inserting Replacing IPC Cards Figure 4 13 Replacing an IPC Card 2 Reattach the card retainer 3 Reinsert the fan tray as described in Removing and Replacing the Fan Tray 4...

Page 56: ...resolution and escalation of issues around the clock Report an issue online at http harmonicinc com webform report issue online Table A 1 Technical Support Phone Numbers and Email Addresses Region Tel...

Page 57: ...ProStream 9100 Release 17 5 Rev A The Harmonic Inc corporate address is Harmonic Inc 4300 North First St San Jose CA 951 34 U S A Attn Customer Support The corporate telephone numbers for Harmonic Inc...

Page 58: ...certifications and approvals In this document we use product equipment and unit interchangeably This equipment generates uses and can radiate radio frequency energy It may cause harmful interference t...

Page 59: ...to do so by this manual Warning Rack Mount Warning To prevent bodily injury when mounting or servicing this unit in a rack special precautions must be taken to ensure your safety and stability of sys...

Page 60: ...DC power module in the same chassis Do not wear hand jewelry or watch when troubleshooting high current circuits such as the power supplies To avoid fire hazard use only the specified correct type vol...

Page 61: ...s fournisseurs de services de consignes de s curit pertinentes dans les manuels Warning Laser Radiation Warning Invisible laser radiation may be emitted from disconnected fibers or connectors Do not s...

Page 62: ...u d effectuer l entretien de l unit moins d instructions contraires dans le pr sent manuel Avertissement Rack Monture Avertissement Pour viter les blessures corporelles lors du montage ou l entretien...

Page 63: ...sol utiliser seulement un linge humide Des courants lectriques dangereux circulent dans cet appareil Afin d viter les lessures ne pas toucher les connexions et composants expos s lorsque l appareil es...

Page 64: ...ter de toucher la carte de circuit imprim et les broches du connecteur Placer un composant retir sur une surface antistatique ou dans un sac de protection statique viter tout contact entre les cartes...

Page 65: ...ntage Warnung Zur Vermeidung von K rperverletzung beim Anbringen oder Warten dieser Einheit in einem Gestell m ssen Sie besondere Vorkehrungen treffen um sicherzustellen da das System stabil bleibt En...

Page 66: ...ehreren Stellen in diesem Produkt Um Verletzungen zu vermeiden ber hren Sie nicht freiliegenden Anschl sse und Komponenten w hrend schaltet ist Sie keine Gegenst nde in einem der beiden Stromversorgun...

Page 67: ...en Ber hren Sie die bedruckte Leiterplatte und Steckerstifte Legen Sie alle entfernten Komponenten auf eine antistatische Oberfl che oder in einem Statik Beutel Kontakt zwischen den Karten und Kleidun...

Page 68: ...ded with stabilizing devices install the stabilizers before mounting or servicing the unit in the rack The rack must be anchored to an immovable support to prevent it from tipping when the unit is mou...

Page 69: ...Disassemble equipment at a dedicated area only gather the needed tools for disassembly 2 Remove covers housing etc 3 Remove and separate sub assemblies i e cables metals displays fans etc 4 Separate...

Page 70: ...th the limits for a Class A digital device pursuant to Part 1 5 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated...

Page 71: ...ouble occurs the user may be required to take corrective actions e BSMI EMC Notice Taiwan English translation of the notice above This is a Class A Information Product when used in residential environ...

Page 72: ...Regulatory Compliance Harmonic products are typically tested to the latest safety and electromagnetic compatibility EMC specifications and test methods and are marked with one or more of the following...

Page 73: ...CE Low Voltage Directive Germany EN 60950 1 EN60825 1 for laser Safety GS Mexico NOM 019 SCFI 1998 Safety NOM Taiwan CNS 1 4336 1 2010 CNS 1 3438 2006 Class A Safety and EMC BSMI Certification RPC Num...

Page 74: ...RoHS Directive and has committed to eliminating or reducing the use of these as well as other environmentally sensitive substances in our products Harmonic also continues to comply with the requiremen...

Page 75: ...H Article 7 1 does not apply to our products For more information please visit REACH regulation page at official EU website http ec europa eu environment chemicals reach reach_en htm China RoHS China...

Page 76: ...ise on the product The EPUP period is valid only when the products are operated or stored as per the conditions specified in the product manual PB X O O O O O X O O O O O X O O O O O X O O O O O X O O...

Page 77: ...ive applies to spent batteries collected together with WEEE and requires their removal and separate collection Once removed from WEEE spent batteries are governed by the Battery Directive Harmonic use...

Page 78: ...e but invites our customers to return the product to us under Harmonic s WEEE Take Back program for product disposal Harmonic will pay for the cost of shipping and will provide a Certificate of Recycl...

Page 79: ...2016 Harmonic Inc All rights reserved...

Reviews:

Related manuals for ProStream 9100