Chapter 4 Transport Stream Configuration
© 2013 Harmonic Inc. Harmonic All rights reserved.
101
Ellipse 3000 Release 3.0, Rev. B
M-SPTS Sub-Menu/Tab
4.3.2.2
Advanced Stream Functions
The Advanced Menu allows the user to set the various Encoder IP Output parameters.
The M-SPTS Advanced features enabled for managing are:
■
FEC Activation
– activates/deactivates the FEC error correction function for the stream.
■
FEC dimension
– The options are: 1D and 2D. The default is
2D
. When an upgrade has been
performed and FEC was already activated then the default is
1D
.
■
FEC Column Number
– sets the FEC error correction column location for the stream.
The range is 01 to 20. (The maximum matrix size is 100.)
■
FEC Row Number
– sets the FEC error correction row location for the stream.
The range is 04 to 20. (The maximum matrix size is 100.)
■
Cascading Included
– enables/disables the cascading ability of the stream.
Front Panel
To set the M-SPTS stream advanced parameters on the front panel:
❖
Navigate
Root > Configuration > Transport Stream > M-SPTS > Transports List >
[Stream Name] > Advanced
.
Web Manager
To access the stream advanced features menu in the Web Manager:
❖
Select
Transport > M-SPTS > [Stream Name]
and go to the Advanced box.
Advanced
1 FEC Activation
Disabled
2 FEC dimension
2D
3 FEC Column Number
06
4 FEC Row Number
06
5 Cascading Included
Disabled