51
1021387 12/2018
V02
Unit
SHG-14
SHG-17
SHG-20
SHG-25
SHG-32
SHG-40
SHG-45
SHG-50
SHG-58
SHG-65
a
[mm]
0.011
0.015
0.017
0.024
0.026
0.026
0.027
0.028
0.031
0.034
b
[mm]
0.017
0.020
0.020
0.024
0.024
0.032
0.032
0.032
0.032
0.032
[mm]
(0.008)
(0.010)
(0.010)
(0.012)
(0.012)
(0.012)
(0.013)
(0.015)
(0.015)
(0.015)
c
[mm]
0.030
0.034
0.044
0.047
0.050
0.063
0.065
0.066
0.068
0.070
[mm]
(0.016)
(0.018)
(0.019)
(0.022)
(0.022)
(0.024)
(0.027)
(0.030)
(0.033)
(0.035)
Table 51.2
The values in brackets are the recommended tolerances for component sets featuring a Wave Generator without Oldham Coupling. The Oldham Coupling
serves to compensate for eccentricity of the input shaft and is available in the standard version. For the direct mounting of a Wave Generator without
Oldham Coupling (Solid Wave Generator) on a motor shaft, the shaft tolerances should fulfill the DIN 42955 R standard.
5.4 Recommended Tolerances for Assembly SHG-2SO and SHG-2SH
In order to use the full performance of Harmonic Drive® Units, it is essential that the tolerances according to
table 51.2 are observed for the input assembly.
Recommended shaft tolerances h6
Recommended housing tolerances H7
Illustration 51.1