LSA-10A-30-D-130 Technical Document
-22-
4-6 Input/Output Interface Specifications
4-6-1 Positioning Command Signal Input [SIG IN(+)/SIG IN(-)]
The differential input of the input impedance is 10k
[Ω].
The scanner rotates in the direction of CW when looking from the output shaft when SIG IN (+) is a positive
voltage and SIG IN (-) is a negative voltage. Examples of connections are as follows.
♦
Examples of the Connections when Positioning Command Signal is Differential Input
Differential Input Examples
Pattern 1
Pattern 2
Pattern 3
Pattern 4
Pattern 5
SIG IN
(+)
0V
+
5V
0V
+
5V
+
4V
SIG IN
(-)
0V
0V
+
5V
-
4V
-
5V
Command
Value
0V
+
5V
-
5V
+
9V
-
9V
*1
The heat sink and GND (↓) are connected through the capacitor (0.1μF).
*2
The standard voltage value within the table is the GND (↓) of the circuit diagram.
♦
Examples of the Connections when Positioning Command Signal is One Terminal Input
Amp
Differential
Output Amp
PSM Side
Ground (Heat Sink)
PSM Side