2-1 FHA-C mini series selection
Selection guidelines
2-1
1
2
3
4
5
6
7
8
9
10
11
Apx
Se
lec
tion gui
de
lin
es
2-1
FHA-C mini series selection
Allowable load inertia moment
To achieve high accuracy and performance, select a FHA-C mini series actuator where the allowable
load inertia moment (reference value) specified for the applicable model No. is not exceeded.
For the calculation of inertia moment, refer to [Apx-2 Calculating inertia moment] (PApx-3).
When temporarily selecting an actuator, make certain that the inertia moment and rotation speed do
not exceed the allowable values shown in the table below.
Actuator model
FHA-8C
FHA-11C
FHA-14C
30
50
100
30
50
100
30
50
100
Reduction ratio
30
50
100
30
50
100
30
50
100
Max. rotational speed
r/min
200
120
60
200
120
60
200
120
60
Inertia
moment
(GD
2
/4) kg
・
m
2
0.0026 0.0073 0.029 0.0062 0.017 0.069 0.019 0.054 0.215
(J) kgf
・
cm
・
s
2
0.027 0.0747 0.298 0.063 0.176 0.705 0.197 0.547 2.189
Allowable load
inertia moment
kg
・
m
2
0.0078
0.022 0.087 0.018 0.051
0.20
0.054
0.15
0.60
kgf
・
cm
・
s
2
0.081
0.23
0.90
0.18
0.51
2.0
0.54
1.5
6.0