Safety Information
5
P R O T E C T I O N F R O M E L E C T R I C S H O C K
• The fixture has an ingress protection rating of IP20 and is for use in dry locations only. Do not expose it to
rain or moisture.
• Do not remove any cover from the fixture except as described under “Service and maintenance” on
• Disconnect the fixture from AC mains power before servicing it and when it is not in use.
• Ensure that the fixture is electrically connected to ground (earth).
• Use only a source of AC mains power that complies with local building and electrical codes and has both
overload and ground-fault (earth-fault) protection.
• The fixture accepts AC mains power at 200-240 VAC (nominal), 50/60 Hz. Do not connect the fixture to
mains power that is not within this range.
• The power input cable must be 14 AWG or 1.5 mm
2
minimum conductor size and heat-resistant to 90° C
(194° F) minimum. Cables must have three conductors and an outer cable diameter of 6 - 12 mm (0.24 -
0.47 in.). In North America the cable must be UL/CSA-recognized, hard usage, type SJT, SJOOW or
better. In the EU, the cable must be type HO5VV-F, H07RN-F or better.
• Connect only a Neutrik powerCON TRUE1 NAC3FX-W (TOP) type cable connector to the power input
socket.
• Before using the fixture, check that all power distribution equipment, connectors and cables are in perfect
condition and rated for the current requirements of all connected devices.
• Isolate the fixture from power immediately if the power plug or any seal, cover, cable, or other component
is damaged, defective, deformed, wet or showing signs of overheating. Do not reapply power until repairs
have been completed.
• The fixture contains components that are accessible and live at high voltage while the fixture is connected
to power and that remain under tension for up to five minutes after power is disconnected. Wait for at least
five minutes after disconnecting from power before opening any of the fixture’s covers.
• Refer any service operation not described in this manual or in the MAC Ultra Performance User Guide to
Martin Service or an authorized Martin Service partner.
• The light source contained in this fixture shall be replaced by Martin Service or an authorized Martin
Service partner only.
P R O T E C T I O N F R O M B U R N S A N D F I R E
• The exterior of the fixture becomes hot during use. After 5 minutes of operation a surface temperature of
85° C (185° F)
shall be expected. The maximum steady state surface temperature is also 85° C (185° F).
Avoid contact by persons and materials.
• Allow the fixture to cool for at least 30 minutes before handling.
• Keep all combustible materials (e.g. fabric, wood, paper) at least 0.2 m (8 in.) away from the fixture.
• Keep flammable materials well away from the fixture.
• Ensure that there is free and unobstructed airflow around the fixture.
• Provide a minimum clearance of 0.2 m (8 in.) around fans and air vents.
• Do not illuminate surfaces within 4.75 m (15.6 ft.) of the fixture.
• Do not expose the front lens to sunlight or any other strong light source from any angle. Lenses can focus
the sun's rays inside the fixture, creating a potential fire hazard.
• Do not attempt to bypass thermostatic switches or fuses.
• Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C (104° F).
• Do not modify the fixture in any way not described in this manual or the fixture’s User Guide or install other
than genuine Martin parts. Do not stick filters, masks or other materials onto any lens or other optical
component. Use only accessories approved by Martin to mask or modify the light beam.
P R O T E C T I O N F R O M E Y E I N J U R Y
• Do not look directly into the fixture’s light output.
• Do not look at LEDs with magnifiers, telescopes, binoculars or similar optical instruments that may
concentrate the light output.
• Ensure that persons are not looking at the fixture when the fixture lights up suddenly. This can happen
when power is applied, when the fixture receives a DMX signal, or when certain control menu items are
selected.
• Disconnect the fixture from power at all times when the fixture is not in use.
• Provide well-lit conditions to reduce the pupil diameter of anyone working on or near the fixture.