Location 

The JEM ZR series machines are designed to be located on the floor or may be 
suspended using the hanging bracket. The machine can operate in any 
orientation from 45° upwards to 45° downwards. Steeper tilting may cause fluid 
leakage. 
 

If the machine is to be suspended, ensure the mounting surface can support the 
weight of the machine. Do not suspend the machine over areas where people 
will be underneath. Use only the hanging bracket to suspend the machine. 
 
Ensure that there is at least 100 mm (4 in.) clearance all-round the machine and 
at least 600 mm (24 in.) in front of the fog output. 
 

 

The machine is delivered with white nylon shipping bolts fitted to the 

hanging bracket in place of the normal hand-wheel bolts. Before first 

use, remove the shipping bolts and replace them with the hand-wheel 

bolts (outside of bracket) and spacers (inside of bracket) which are 

supplied separately in the packaging. 

 

AC power 

 
Before using the machine, ensure that a grounding-type (earthed) power plug 
that fits the local power receptacle is installed on the power cable provided. 

 

 

DANGER! Make sure the power plug is correctly rated: 

  For EU ZR25, ZR35, ZR45 models use a plug rated at 10 A minimum. 

  For US ZR25 use a plug rated at 10 A minimum. 

  For US ZR35 use a plug rated at 15 A minimum. 

  For US ZR45 use a plug rated at 20 A minimum. 

 

 
When installing the plug, follow the plug manufacturer’s instructions and 
connect pins as follows: 

Yellow and green wire to ground (earth), blue wire to neutral and brown wire to 
live.  
 
The table below shows some common pin identification schemes. 
 

wire 

function 

marking 

screw colour 

brown 

live 

“L” 

yellow or brass 

blue 

neutral 

“N” 

silver 

green/yellow 

earth 

 

green 

 
  
 

Summary of Contents for Martin JEM ZR Series

Page 1: ...user manual READ AND SAVE THESE INSTRUCTIONS...

Page 2: ...Dimensions Legal All dimensions are in millimeters...

Page 3: ...quential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Martin and JEM are registered trademarks of HARMAN PROFE...

Page 4: ...ut density 15 Setting the Timer 16 Using the Settings menu 16 Setting the DMX start address 16 Display back light setting 16 Setting the host client link mode 17 Priming the machine after fluid out 17...

Page 5: ...ctric shocks Always ground earth the machine electrically Use only a source of AC power that complies with local building and electrical codes and that has both overload and ground fault protection Be...

Page 6: ...and rating specified in this manual for the machine Provide a minimum free space of 100 mm 4 in around the machine Provide a minimum free space of 500 mm 20 in around fans and air vents and ensure fr...

Page 7: ...s SKIN Remove contaminated clothing and rinse skin for 20 minutes seek medical attention if irritation persists Consult the fluids SDS for more detailed safety information at www martin com support co...

Page 8: ...and used at a distance or the machines may be operated by DMX with full RDM capability for remote setup and status monitoring This manual contains instructions for all machines in the range but some...

Page 9: ...witch Mains power connector Fluid pipe connection Fluid Reservoir Integrated Digital Remote Control Mains fuse Product details ZR25 Fog output nozzle WARNING High temperature vapour and surfaces If su...

Page 10: ...itch Mains power connector Fluid pipe connection Fluid Reservoir Integrated Digital Remote Control Mains fuse ZR35 Fog output nozzle WARNING High temperature vapour and surfaces If suspending overhead...

Page 11: ...s power switch Mains power connector Fluid pipe connection Fluid Reservoir Integrated Digital Remote Control Mains fuse ZR45 Fog output nozzle WARNING High temperature vapour and surfaces If suspendin...

Page 12: ...ear of the unit to the ON I position The display will show HEAT If the display shows OFF press the FOG button on the control panel or set the RUN MODE to CONTINUOUS After about 6 8 minutes the display...

Page 13: ...ing bolts fitted to the hanging bracket in place of the normal hand wheel bolts Before first use remove the shipping bolts and replace them with the hand wheel bolts outside of bracket and spacers ins...

Page 14: ...ts stated on page 13 the operator is familiar with and able to comply with the requirements for safe operation listed on page 5 the fluid is one of the approved Martin fluids listed under Approved Fog...

Page 15: ...o be used to shut down the heater Settings are OFF shutdown heaters off STANDBY heaters remain on TIMER or CONTINUOUS mode Use the Menu Previous Next buttons to select the RUN MODE option Use the Up D...

Page 16: ...rightness Host Client linking priming factory reset and temperature control ZR45 only are found in the SETTINGS menu Use the Previous Next buttons to select the SETTINGS option Press the Enter button...

Page 17: ...UID OUT on the display to prevent damage to the pump s To suck the new fluid back into the machine and reset the FLUID OUT error replace refill the fluid reservoir and use the prime function Use the P...

Page 18: ...The factory settings are option setting FOG LEVEL 50 TIMER ON 10 seconds TIMER OFF 20 seconds RUN MODE STANDBY DMX 001 BACK LIGHT NORM LINK MODE RECEIVE1C PRIME NO TEMPERATURE NORM ZR45 Only...

Page 19: ...to this state If the machine was set to CONTINUOUS it will revert to this state Connection The JEM ZR series machine provides 5 pin XLR connectors on the rear of the machine for DMX connection For be...

Page 20: ...efore you can communicate with fixtures using RDM you must send a scan command also called a device discovery command to all the devices on the data link so that the RDM controller can identify them I...

Page 21: ...ATUS_MESSAGES DEVICE_MODEL_DESCRIPTION MANUFACTURER_LABEL DEVICE_LABEL FACTORY_DEFAULTS DMX_PERSONALITY DMX_PERSONALITY_DESCRIPTION DEVICE_HOURS BOOT_SOFTWARE_VERSION_ID BOOT_SOFTWARE_VERSION_LABEL SL...

Page 22: ...is often preferred JEM Pro Fog Fluid Quick Dissipating offers a less dense effect compared to the benchmark JEM Pro Fog Fluid and is therefore less likely to interfere with video and film camera focu...

Page 23: ...uid RUSH Fog Fluid RUSH ELX Smoke Fluid Regular DJ Fluid DJ ZR45 Temperature Menu The different fluid types listed require correct selection of the relevant temperature setting in the TEMPERATURE sub...

Page 24: ...fect heat exchangers This advanced preventative maintenance fluid has been utilized by Martin service technicians for years of both cleaning and storing effect machines Utilizing Martin Pro Clean Stor...

Page 25: ...inside the unit which protects the supply to the pump DANGER Disconnect the power supply before removing any covers or changing fuses Live parts inside Rear panel fuse ZR25 120 V 10 A 250 V 230 V 6 3...

Page 26: ...on in DMX line Check DMX cables and connections LINK menu is set to SEND Set LINK menu to RECEIVE Fog output is weak Machine requires priming Use PRIME option to prime the machine page 17 Wet greasy n...

Page 27: ...e heater is at operating temperature and the unit is under DMX control FLUID OUT Run out of fluid Refill the fluid reservoir and operate the prime function in the SETTINGS menu CALIBRATION ERROR The m...

Page 28: ...189 ft per minute Fluid consumption max 100 ml per minute Maximum operating time maximum output 2 5 l of fluid 1 2 hours ZR35 Continuous effect output Ready time 9 minutes Coverage volume 800 m 28 25...

Page 29: ...lation Mounting Standing or hanging Clearance around machine 100 mm 4 in Orientation Up to 40 from horizontal Connections AC Power Neutrik PowerCON TRUE1 DMX Link mode in out 5 pin locking XLR Remote...

Page 30: ...ON TRUE1 molded NEMA 5 20P 2 m 6 6 ft P N 11501046 Accessories JEM ZR25 Ducting System with 5 m 16 4 ft ducting P N 92625012 JEM ZR35 Ducting System with 5 m 16 4 ft ducting P N 92625013 JEM ZR45 Duct...

Page 31: ...JEM ZR45 EU P N 92215360 Specifications subject to change without notice For the latest product specifications see www martin com Disposing of this product Martin products are supplied in compliance...