background image

JBL Professional

®

 Intellivox ADC Installation Manual

17

202011/ADCIM

MOUNTING PROCEDURE 

The general procedure for mounting the Intellivox ADC 
Models V90 or H90 using the standard brackets is described 
below. It is assumed that cabling for connection to the  
100 V/70 V line system has been run to the loudspeaker 
location. 

Proceed as follows: 

1.  Use of the wall plugs and hexagon head screws

supplied is recommended. If using other types, ensure
that the “across-flats” head size does not exceed 11.5
mm (0.45”).

2.   Mark and drill the holes (8 mm) for the wall plugs. For the 

V90 use the two holes with the slots running vertically as
reference. For H-90 use the slotted hole in the centre of
the bracket as reference.

3.  Insert the plugs and screws into the holes. Tighten

the screws with a spanner, but stop with a few mm of
screw shaft visible between the head and the wall.

4.  Check that it is possible to slide a bracket over the

heads.

5.  Check that the chosen mounting points will position

the column in the correct vertical angle specified by
the acoustic design (in the case of the Model V90, this
is usually exactly perpendicular to the listening area).
Use spacers on one or both  brackets if necessary.

6.  Attach the brackets to the rear of the loudspeaker

using the M5 x 12 pan-head screws and shakeproof
washers supplied. The 10 mm diameter holes allow
screwdriver access to the screw heads.

7.  Remove the front grill from the loudspeaker by gently

lifting it at the locations of the ‘snap-on’ fittings which
hold it in place. Remove the protective foam. Unscrew
the four self-tapping screws securing the connector
compartment cover and remove the cover.

8.  Lift the loudspeaker and slide the brackets over the

heads of the hex-head screws protruding from the wall,
and at the same time feed the speaker cable through
the cable entry gland at the rear and into the connector
compartment so that it is free and accessible from the
front. Tighten the rear gland, leaving sufficient free
cable to connect to the terminal block.

Ensure that the gland fits tightly around the 
cable jacket. The enclosure protection, as 

 well as the LF SPL response, will deteriorate in  case of 
a leaky enclosure.

9.  Firmly fasten the screws securing the brackets to the

wall with the spanner. Re-check the verticality (or other 
angle if specified) with a spirit level or similar levelling
device.

10.  The loudspeaker connections should now be made –

see section on Wiring Details on page 14.

fig.6 - Bracket attachment

fig.7 - Connector cover 

location

H90

V90

Summary of Contents for JBL Intellivox ADC-V90

Page 1: ...Installation Manual Intellivox ADC V90 ADC H90 models SKU IVX 576125 IVX 577125 IVX 577135 IVX 576126 IVX 577126 and IVX 577136 EN54 24...

Page 2: ...ls Construction product description Loudspeaker for voice alarm systems for fire detection and fire alarm systems for buildings Product model type ADC V90 ADC H90 Document references Datasheet s 20201...

Page 3: ...in accordance with the applicable harmonised technical specification as foreseen by the manufacturer Construction product Loudspeaker for voice alarm systems for fire detection and fire alarm systems...

Page 4: ...ystem 1 7 Declaration of performance concerning a construction product covered by a harmonised standard Notified body details Name Scientific and Research Centre for Fire Protection named after J zef...

Page 5: ...assed Section 4 4 Marking and data Passed Section 4 5 Rated noise power durability Passed Section 5 6 Enclosure protection Passed Section 5 18 Dry heat operational Passed Section 5 7 Dry heat enduranc...

Page 6: ...performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 9 This declaration of performance is issued under the sole responsibility of the manufa...

Page 7: ...te names mentioned in this manual may be registered trademarks or copyrights of their respective companies They are used here for indicative purposes only The information contained in this manual has...

Page 8: ...ion 11 Applicable models and variants 11 What s in the packaging 12 3 Installation Guide 13 Preparing for Installation 13 Intellivox ADC connections 13 Mechanical Installation 14 Model V90 only 14 Mod...

Page 9: ...s radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Only use attachments accessories specified by the manufacturer 10 Use only with the cart stand tripod brac...

Page 10: ...thermal fuse and ceramic terminal block EQ correction and high pass filter This manual covers Wiring and connection details Mechanical installation of the loudspeaker Please note that a full range of...

Page 11: ...is document ADC Datasheet Box containing REF ITEM QTY USE A Mounting brackets 2 Speaker mounting B 30 mm hex headed screws with washers and wall plugs 4 Mounting bracket fixings wall C M5 x 12 mm pan...

Page 12: ...acket positions are in the same plane This restriction does not apply to the Model H90 which is intended to be tilted downwards INTELLIVOX ADC CONNECTIONS The Intellivox ADC range loudspeakers are des...

Page 13: ...cker see fig 3 The horizontal position is on the vertical centre line When calculating the positions for the mountings see below the distance from the acoustic centre to the top or bottom of the louds...

Page 14: ...wnwards radiating angle of the unit is correct fig 4 2 Acoustic centre reference point for H90 Reference point for acoustical mounting position H90 fig 4 3 H90 further mounting information A C H90 B M...

Page 15: ...mation 3 The third method is to mount the column within a recess in the wall or dedicated mounting panel so that the front of the unit is flush This is a specialised mounting situation which will be e...

Page 16: ...s on one or both brackets if necessary 6 Attach the brackets to the rear of the loudspeaker using the M5 x 12 pan head screws and shakeproof washers supplied The 10 mm diameter holes allow screwdriver...

Page 17: ...g location the wiring scheme as indicated in fig 8 2 can be used Note that the application dependent safety regulations should be consulted in order to determine the proper grounding scheme TAP SETTIN...

Page 18: ...sition The frequency response of the high pass filter is indicated in fig 10 2 Model V90 respectively fig 10 4 Model H90 The filter response is slightly dependent on the tap setting the curves are val...

Page 19: ...lot tones of other frequencies and or levels may be used if the fault monitoring system demands them the illumination of the LED is not essential for such a system to operate correctly SPEAKER PROTECT...

Page 20: ...SKU Intellivox wall bracket set 2 pcs 25 mm RAL 9007 IVX 802227 Intellivox hinge bracket 90 RAL 9007 IVX 802005 Intellivox swivel bracket 90 RAL 9007 IVX 806668 Intellivox swivel bracket 45 RAL 9007 I...

Page 21: ...JBL Professional 8500 Balboa Boulevard Northridge CA 91329 U S A Copyright 2020 JBL Professional www jblpro com...

Reviews: