Harman AMX NMX-WP-N1512 User Manual Download Page 1

USER MANUAL

N1512 4X1 WINDOWING PROCESSOR

HIGH-RESOLU TION, WINDOW PROCESSING

OVER AN ETHERNET LAN

NMX-WP-N1512

Summary of Contents for AMX NMX-WP-N1512

Page 1: ...USER MANUAL N1512 4X1 WINDOWING PROCESSOR HIGH RESOLUTION WINDOW PROCESSING OVER AN ETHERNET LAN NMX WP N1512...

Page 2: ...outlet 10 PROTECT the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 ONLY USE attachments accessories spec...

Page 3: ...rient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connec...

Page 4: ...ssigning IP Addresses Individually using the Settings page 14 Option 2 Assigning IP Addresses to Multiple Units using CSV files 15 Control Options 15 Primary Control Options 15 N Command Controllers 1...

Page 5: ...5 N1512 Windowing Processor User Manual Native Commands Port 1 31 Windowing Processor Pass Through Command Examples 32 Appendix B Minimum Network Requirements 33...

Page 6: ...ected to active streams IMPORTANT To avoid creating a network loop never connect more than one P port to the same network segment To achieve larger stacked configurations additional Windowing Processo...

Page 7: ...o reset but not lose power A reset does NOT affect the current settings Press and hold for 30 seconds to perform a factory restore Diagnostic LEDs LEDs 0 3 Lower row On solid green signifies receipt o...

Page 8: ...r New N1512 Windowing Processor 8 N1512 Windowing Processor User Manual Application Example FIG 2 Windowing Processor Application Example Note Single line represents four independent connections from...

Page 9: ...rovided here assume the following to be true 1 There are switches operational on the network N Series equipment can operate on many different brands of networking equipment The network itself needs to...

Page 10: ...cally based on the network DHCP server If no DHCP server is found the unit will switch to Auto IP mode with a default IP address of 169 254 xxx xxx Before beginning installation you will need to make...

Page 11: ...units in Auto IP mode will not self assign in the 169 254 0 xxx range NOTE If the computer has a statically assigned IP address click the Advanced button Then click Add to enter a unique 169 254 xxx...

Page 12: ...r launch N Able to view all discovered units The N1512 units appear on the following tabs Unit Management tab Windowing Processor is listed in the Type field Video Matrix tab N1512 units are found on...

Page 13: ...ce logged in you can change the password using the options on the Unit Settings page The Login page is only displayed if N Able s stored username password does not match the unit s username password A...

Page 14: ...units using N Able Option 1 Log in to each unit individually and make the changes on the Unit Settings page Option 2 Export a comma separated value CSV file make changes to all units in the resulting...

Page 15: ...t Control Options N Series control solutions N Command N Act and N Touch provide you with the most flexible management options available insuring you are getting the most from your digital media syste...

Page 16: ...the Windowing Processor web interface refer back to the Logging in to the Windowing Processor s Web Interface section on page 13 From any main page in the GUI you can access all other main pages by c...

Page 17: ...ging and dropping resizing etc You can fine tune adjustments by directly entering values in the fields on the right side of the screen Number tabs 1 4 Select the window for which you would like to vie...

Page 18: ...rrange windows into one of the factory pre set choices Load Custom Preset dropdown Click to automatically arrange windows into one of the custom pre set choices saved to this Windowing Processor Backg...

Page 19: ...Zoom Page Options Option Description Window Number tabs 1 4 Select the window for which you would like to view edit settings X1 Y1 Set pixel coordinates of cropping area top left X2 Y2 Set pixel coor...

Page 20: ...to access the page shown in Figure 11 The Unit Settings page is divided into several sections Refer to the following sections for detailed descriptions Unit Setup Section on page 21 Stored Presets Sec...

Page 21: ...rocessor Enable this option prior to viewing the output of the N1512 with a Decoder When enabled you can route AV streams in N Able or your other configuration choice to the four windows and route the...

Page 22: ...t have MPC support Output Sync Enable to sync the Windowing Processor video output to the video stream input given by the Sync Stream setting described next Sync Stream Enter the video stream number t...

Page 23: ...box Enable this checkbox if you want to append the current stored presets with the imported presets If this option is not enabled the import will overwrite the currently stored presets TABLE 6 Unit Se...

Page 24: ...ssword for admin level access enter the current password in the field labeled Old Password and enter a new password in the New Password and Confirm Password fields Click Change PW to accept the new pa...

Page 25: ...Sys Description Port ID and Port Description fields all reflect the information that was entered on the connected switch s web interface FIG 19 LLDP Page TABLE 8 Unit Settings Page Software Section O...

Page 26: ...shown in Figure 20 The Logs page displays a command log that lists all TCP and UDP messages the unit receives It also displays the web browser s IP address and gives you options to Refresh and Reset...

Page 27: ...l NetLinx Page Click the NetLinx link at the top of any of the main web pages to access the page shown in Figure 21 This page allows you to prepare your Windowing Processor for NetLinx driven configur...

Page 28: ...d sources connected to all four U ports Are the AV sources properly routed to windows of the N1512 Is the network configured appropriately for N1000 AV traffic Did you assign unique IP addresses for e...

Page 29: ...tional product documentation found on our website at http www amx com techcenter manuals asp Common Applications NetLinx Studio is a Microsoft Windows program that integrates programming organization...

Page 30: ...e NetLinx On button and click the OK button at the bottom of the screen FIG 24 Enabling NetLinx on Multiple Units NOTE Items are not filtered In other words if you send a NetLinx command to a device t...

Page 31: ...st be sent to D P S port 1 Syntax SEND_COMMAND DEV CA stream Variables stream The target stream number from 0 to 32767 Set to 0 for the audio stream to follow the video stream Examples SEND_COMMAND 50...

Page 32: ...1 960 0 1919 539 SEND_STRING DEV setz 1 2 SEND_STRING DEV winon 2 SEND_STRING DEV set 2 stream window 2 SEND_STRING DEV setbordcol 2 255 255 255 SEND_STRING DEV bordoff 2 SEND_STRING DEV winset 2 0 5...

Page 33: ...iate Leave also know as Fast Leave etc depending on switch manufacturer NOTE If Immediate Leave is disabled set IGMP Robustness to Default 2 Robustness can be adjusted generally from 2 10 The higher t...

Page 34: ...sponsibility for errors or omissions AMX also reserves the right to alter specifications without prior notice at any time The AMX Warranty and Return Policy and related documents can be viewed downloa...

Reviews: