background image

1

Soundweb

TM

 

London 

BLU-GPX

Installation Guide

5009104-B

www.audiovias.com

Summary of Contents for 5009104-B

Page 1: ...1 Soundweb TM London BLU GPX Installation Guide 5009104 B www audiovias com ...

Page 2: ...ed service personnel or equivalent If connected to 240V supply a suitable CSA UL certified power cord shall be used for this supply This Equipment is intended for rack mount use only Safety Instructions Notice For Customers If Your Unit Is Equipped With A Power Cord WARNING THIS APPLIANCE SHALL BE CONNECTED TO A MAINS SOCKET OUTLET WITH A PROTECTIVE EARTHING CONNECTION The cores in the mains lead ...

Page 3: ...arge to designated collection facilities or to a retailer if you purchase a similar new one For Countries not mentioned above please contact your local authorities for a correct method of disposal By doing so you will ensure that your disposed product undergoes the necessary treatment recovery and recycling and thus prevent potential negative effects on the environment and human health DECLARATION...

Page 4: ...e sleeve STEWART TYPE 28A2029 0A0 near the network socket end This equipment must be earthed It should not be necessary to remove any protective earth or signal cable shield connections to prevent ground loops Any such disconnections are outside the recommended practice of BSS Audio and will render the EMC or safety certificate void If the unit is likely to undergo extreme vibration through extens...

Page 5: ...e device is communicating with another control device either on the network or via the serial or control ports LCD Display Top line Indicates device name and run state Bottom line indicates Time IP Address Subnet Mask Model number with firmware version Also the device s MAC Address can be viewed by powering the device on whilst pressing and holding the LOCATE switch This display can be configured ...

Page 6: ...t closures for controlling binary parameters resistor ladders for controlling multi state parameters or potentiometers for controlling continuous parameters e g BLU 3 selector wallplate Part no Z BLU 3 The BLU GPX has 47 Common ground connections labelled C A multiplicity of Common connections results in simplified wiring to and from external equipment reducing the need to span connections across ...

Page 7: ...y Open NO and Normally Closed NC terminals will open or close in response to HiQnet parameters They can be connected directly to resistance controlled electrical components circuits These RELAY OUTPUTS reduce the need to source and deploy external relays www audiovias com ...

Page 8: ...47kOhm log potentiometer Part no DM10018 connected between a control input and common will allow parameters to be controlled linearly 3 wire mode This mode allows the use of linear pots or faders for continuous controls A pot would be wired as a potential divider with the top of the track connected to the reference output R the wiper to a control input and the bottom of the track to a common C For...

Page 9: ...voltage ground relay coil relay coil NC Normally Closed NO Normally Open C Common relay NC C NO Relay Outputs Logic Opto Outputs Relay Outputs LED supply voltage ground relay coil relay coil NC Normally Closed NO Normally Open C Common relay NC C NO www audiovias com ...

Page 10: ...WER AND DIMENSIONS Primary IEEE802 3af Power over Ethernet PoE Secondary 12 48VDC 19W external power supply Operating Temp Range 5 41 to 35 95 degrees C degrees F Dimensions HxWxD 1 75 45mm x 19 483mm x 7 75 197mm Weight 2 96 lbs 1 34 kg BSS Audio incorporates high quality mechanical fans in some products All mechanical fans have a limited life expectancy We recommend annual inspection of fans for...

Page 11: ...11 This page intentionally left blank www audiovias com ...

Page 12: ...12 BSS Audio 8760 South Sandy Parkway Sandy Utah 84070 801 566 8800 www bssaudio com Printed in the USA www audiovias com ...

Reviews: