background image

29

 

Harman Gold Warranty

HARMAN GOLD WARRANTY
6 YEAR TRANSFERABLE LIMITED
WARRANTY (Residential)

1 YEAR LIMITED WARRANTY (Commercial)

Harman  Stove  Company  warrants  its  products  to  be  free  from  defects  in  material  or  workmanship,  in  normal  use  and

service,  for  a  period  of  6 years  from  the  date  of  sales  invoice  and  for  mechanical  and electrical  failures,  in  normal  use  and
service, for a period of 3 years from the date of sales invoice.

If defective in material or workmanship, during the warranty period, Harman Stove Company will, at its option, repair or

replace the product as described below.

The warranty above constitutes the entire warranty with respect to Harman Stove Company products.  HARMAN STOVE

COMPANY  MAKES  NO  OTHER  WARRANTY,  EXPRESSED  OR  IMPLIED,  INCLUDING  “ANY”  WARRANTY  OF

MERCHANTABILITY,  OR  WARRANTY  OF  FITNESS  FOR  A  PARTICULAR  PURPOSE.  No employee, agent, dealer, or
other  person  is  authorized  to  give  any  warranty  on  behalf  of  Harman  Stove  Company.    This  warranty  does  not  apply  if  the
product has been altered in any  way after leaving the factory.  Harman Stove Company and  its agents assume no liability for

“resultant damages of any kind” arising from the use of its products.  In addition, the manufacturer and its warranty administra-

tor shall be held free and harmless from liability from damage  to property related to the operation, proper or improper, of the
equipment.

THERE  ARE  NO  WARRANTIES  WHICH  EXTEND  BEYOND  THE  DESCRIPTION  ON  THE  FACE  HEREOF.

THESE  WARRANTIES  APPLY only if the device is installed and operated as recommended in the user’s manual.

THESE  WARRANTIES WILL  NOT  APPLY if abuse, accident, improper installation, negligence, or use beyond rated

capacity causes damage.

HOW  TO MAKE A CLAIM - Any claim under this warranty should be made to the dealer from whom this appliance was

purchased.  Then contact is made with manufacturer, giving the model and serial numbers, the date of purchase, your dealer’s

name  and  address,  plus  a  simple  explanation  of  the  nature  of  the  defect.    Extra  costs  such  as  mileage  and  overtime  are  not
covered.  Nuisance calls are not covered by these warranties.

THIS   WARRANTY   IS   LIMITED   TO   DEFECTIVE   PARTS - REPAIR   AND/OR   REPLACEMENT   AT   HARMAN

STOVE  COMPANY’S   OPTION   AND   EXCLUDES   ANY  INCIDENTAL   AND   CONSEQUENTIAL   DAMAGES

CONNECTED  THEREWITH.

WARRANTY EXCLUSIONS:  Failure due,  but not  limited to, fire,  lightning, acts  of God,  power failures  and/or surges,

rust,  corrosion  and  venting  problems  are  not  covered.    Damage  and/or  repairs  including  but  not  limited  to;  remote  controls,
filters, fuses, knobs, glass, ceramic brick panels, ceramic fiber afterburners, door packing, tile, ceramic log sets, paint, batteries
or battery  back-up and  related duct  work are not  covered. Also  excluded from this  warranty are  consumable or  normal wear
items including but not limited to; flame guides, grates, coal bars, afterburner hoods, fire brick, gaskets. Additional exclusions
for  corn  stoves  are  burnpot  housing  weldment,  burnpot  grate  weldment  (pellet  or  corn),  burnpot  front  plate  (pellet  or  corn),
burnpot front plate lock, corn auger extension, ceramic insert, and ceramic insert plate. Additional or unusual utility bills incurred
due to any malfunction or defect in equipment and the labor cost of gaining access to or removal of a unit that requires special

tools or equipment are not covered.  Maintenance needed to keep the stove in “good operating condition” is not covered.  This

includes, but is not limited  to, cleaning, adjustment of customer controls and customer  education.  Labor, materials, expenses
and/or equipment needed to comply with law and/or regulations set forth by any governmental agencies are not covered.

This Warranty provides specific legal rights and the consumer may have other rights that vary from state to state.
In  the  event  of  change  in  ownership,  the  remaining  portion  of  this  warranty  may  be  transferred  to  the  new  owner  by

sending the  new owner  information to  the Harman  Stove Company.

PLEASE  READ  THE  LITERATURE  BY  THE  MANUFACTURER  FOR  THE  VARIOUS  ACCESSORY  DEVICES.

THE MANUFACTURER  WARRANTS  THESE  ACCESSORY  DEVICES,  NOT  HARMAN  STOVE  COMPANY  OR  THEIR
WARRANTY  ADMINISTRATOR.   FURTHERMORE,  THESE  ACCESSORY  DEVICES  MUST  BE  INSTALLED  AND
USED ACCORDING  TO  THE  RECOMMENDATIONS  OF  THE  MANUFACTURER.

REMEDIES - The remedies set forth herein are exclusive and the liability of seller with respect to any contract or sale or

anything done in connection therewith, whether in Contract, in tort, under any warranty, or otherwise, shall not, except as herein
expressly provided, exceed the price of the equipment or part of which such liability is based.

CLARIFY  -  The  above  represents  the  complete  warranty,  which  is  given  in  connection  with  stoves,  manufactured  by

Harman  Stove  Company.    No  other  commitments,  verbal  or  otherwise,  shall  apply  except  by  a  written  addendum  to  this
warranty.

Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.

Summary of Contents for Accentra 2

Page 1: ...R YOURSAFETY FOLLOW INSTALLATIONDIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALSABOUT RESTRICTIONSAND INSTALLATIONINSPECTION REQUIREMENTS INYOUR AREA CONTACT YOUR LOCAL AUTHORITY SUCH AS MUNICIPAL...

Page 2: ...ed premium pellets The control is designed for easy andefficient operation It has 2 automatic modes of operation and 2 manualmodes of operation The Accentra uses a small roomsensor rather then a wall...

Page 3: ...m temperature Therefore as it gets colder more pellets will be burned automati cally The distribution blower speed will vary according to the position of the mode selector pointer and fire size Ignito...

Page 4: ...need to be increased After you know a feed rate setting that works well use that setting Remember ifyour feed rate is too high youmay waste fuel 5 This is usually a weekly maintence procedure Cleaning...

Page 5: ...bution fan will not operate A 5 on the temperature dial and a 5 on the feed adjuster is approximately 80 output It is not necessary to oper ate the distribution blower below this point Therefore there...

Page 6: ...will probably need to be increased After you know a feed rate setting that works well use that setting Remember ifyourfeed rateis too high you may waste fuel 5 This isusually a weekly maintence proce...

Page 7: ...Room Temp Mode Stove Temp Mode orOFF Also allows you to vary the distribution blower speed by turning the knob to the high or lowside of each mode Feed adjuster Sets the maximum feed rate Test Runs a...

Page 8: ...al must be installed between the bottom of the unit and the floor This can be a minimum of a 20 gauge sheetmetal plate ceramic tile with grouted joints a UL listed stove board or a Harman Cast Iron fl...

Page 9: ...er moving parts will not be transferred by direct contact These rubber pads have a threaded stud that extends through the base plate The top of the threaded stud has a screwdriver slot Therefore the u...

Page 10: ...of the Accentra Pellet Stove should be done by a qualified service person The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning will...

Page 11: ...l not allow the feeder motor or the ignitor to operate A simple draft test should be performed after completing the flue pipe installation To record the results for future reference 1 Plug unit into a...

Page 12: ...d even if only installed on the rear of the unit as a returnair sensor There is anintake screen onthe bottomof the rear sheetmetalenclosure This is an ideal place to tyrap the sensor head to sense ret...

Page 13: ...o layers with air space between the layers This air space acts as an insulator and reduces the outside surface temperature to allow a clearance to combustibles of only 3 inches The sections of pipe lo...

Page 14: ...ing KEEP COMBUSTIBLES SUCH AS GRASS LEAVES ETC AT LEAST 3 FEET AWAY FROM THE FLUE OUTLET ON THE OUTSIDE OF THE BUILDING CAUTION 3 ft to combustibles 2 Preferred method This method also provides excell...

Page 15: ...provides excellent venting for nor mal operation This method also provides natural draft in the event of a power failure The damper area must be sealed with a steel plate or fiberglass A cap should b...

Page 16: ...increased to 4 using this method This method provides excellent venting for nor mal operation This method also provides natural draft in the event of a power failure In Canada and some places in the U...

Page 17: ...using wall and ceiling pass through Note Do not place joints within wall pass throughs PL vent manufacturer s firestop spacer and support No insulation or other combustible materials are allowed with...

Page 18: ...ed fromthe horizontalcenter line of the regu lator 1 I The clearance to service regulator vent outlet must be a minimum of 6 feet 1 J The clearance to a non mechanical air sup ply inlet to the buildin...

Page 19: ...efore if the unit is turned to the lowest setting about 1 hour before cleaning it will make it possible to clean the glass with the unit in operation Any glass cleaner with a high amonia content will...

Page 20: ...opening Repeat the process withthe secondheat exchanger cover Maintenance Cleaning Heat Exchanger channel cover latch Fig 36 Fig 35 Cleaning Internal Components Feeder Chamber This chamber may get a...

Page 21: ...n Use the scraper provided to clean the heat exchanger surfaces A wire brush or short bristled brush is an excellent cleaning tool Clean the fan blade and combustion blower fan housing NOTE Be careful...

Page 22: ...ctors These connections between the hot leads the wires inside the burn pot and the cold leads the wires from the control board are always pulled to the inside rear of the feeder body Not coiled insid...

Page 23: ...ssure becomes too low for proper combustion the switch opens turning off the feeder motor and the igniter element This switch is connected into the AC high voltage wires therefore the control may show...

Page 24: ...licone FIRE HAS GONE OUT 1 No pellets in hopper 2 Draft setting is too low 3 Something is restricting fuel flow 4 Feed motor or draft motor has failed 5 Power failure or blown fuse SMOKE IS VISIBLE CO...

Page 25: ...ellets Outside Air Size 2 3 8 inches Fuse Rating 5 amp BTU Range 0 to 40 000 Feed Rate 75 lbs hr on minimum on maintenance 5 lbs hr on maximum Flue Size 3 inch Pellet Vent Pipe Maximum Wattage 440 Wat...

Page 26: ...26 Accentra Wiring Diagram...

Page 27: ...ade 8 3 30 1252010014 SHCS 1 4 20 x 3 4 3 30 3025200752 HCS 5 16 18 x 1 1 4 3 30 1311812513 Motor Mount Weldment 1 10 06603 HWH TCS 10 24 x 3 4 Black 3 30 110240753 4 Rubber Grommet 3 31 960026 4 Nylo...

Page 28: ...lePaddle Combustion Fan Blade 3 20 40985 Combustion Blower 3 21 08639 Distribution Blower 3 21 29045 Tailpipe Insulator 3 44 247168 White Black Control Knob 3 3 31 00968 Control Knob Shaft 3 3 31 0098...

Page 29: ...NS Failure due but not limited to fire lightning acts of God power failures and or surges rust corrosion and venting problems are not covered Damage and or repairs including but not limited to remote...

Reviews: