background image

PART # 

 

DESCRIPTION 

1. 

CLC-BLOCK  

LATCHTAP BLOCK 

2. 41S-6 

 

BRASS FLARE NUT(included in CPE-PO) 

3. SC-1  

 

STAINLESS TUBING(included in CPE-PO) 

4.  68-6  

 

BRASS 3/8”FIP X 3/8” COMPRESSION 

5. N-6X1.5 

 

3/8 X 1.5 PIPE(included in CPE-PO) 

6. LTHS 

 

LATCHTAP HEAT SHIELD 

 
 

SWITCHING DEVICE FOR MATCHING KIT 

LCK-RC (REMOTE CONTROL KIT) 

A.  RC-S6V-LT 

 

REMOTE CONTROL  

1.  (4) AA Batteries   

NOT PICTURED

 

2.  A23 Battery 

 

NOT PICTURED

 

LCK-BC (BARK CHIP KIT) 

 

 

B. BPBCS 

 

BARK CHIP SWITCH 

1. 9v BATTERY 

 

NOT PICTURED

 

LCK-WS (WALL SWITCH KIT) 

C. WG-WS 

 

WALL SWITCH 

1. (4) AA Batteries   

NOT PICTURED 

LCK-WWS (WIRELESS WALL SWITCH KIT) 

D. WS-S6V-LTST   

WIRELESS WALL SWITCH 

1.  (4) AA Batteries   

NOT PICTURED 

2.  CR2032 

 

NOT PICTURED

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 

INSTALLATION  

1.    Use  the  CPE-PO  (Safety  Pilot  Valve  Kit)  Installation 
Instruction  to  properly  install  the  Extension  Connector  and 
Pilot Assembly to the Ember Burner.  
2. Attach the N-6X1.5 to the side port of the CLC-BLOCK. 
3.  Attach  the  other  end  of  the  N-6X1.5  to  the  outlet  side  of 
the CPC-C  
4. SC-1 assembly 

– Slide the 41S-6 onto the SC-1with both 

flared  ends  going  the  same  direction.    Attach  the  68-6 
compression  fitting  to  the  SC-1  by  sliding  the  nut  and  then 
the  ferule  from  the  68-6  onto  the  SC-1  then  threading  and 
tightening the compression end of the 68-6 to the nut. 
5. Attach the 68-6 end of the SC-1 assembly to the back port 
of the CLC-BLOCK. 
6.  Verify  that  the  brass  elbow  49-6-6  is  attached  to  the 
ember  burner  and  the  flared  end  is  facing  forward.    Attach 
and tighten the 41S-6 end of the SC-1 to the 49-6-6. 
7.    Attach  the  wires  on  the  CLC-BLOCK  to  the  Switching 
Device included in the LCK kit. 
8.    Assure  the  switching  device  is  located  as  close  to  the 
front  opening  of  the  fireplace  and  as  far  away  from  the 
Ember Burner pan as possible.   
9. Follow the Lighting Instructions in the CPE-PO Installation 
instruction for proper lighting procedures. 
 

HARGROVE GAS LOG 

LATCHTAP KIT (LCK-RC, LCK-BC,  

LCK-WS, LCK-WWS) 

INSTALLATION INSTRUCTION 

 

 

 

 

NOTE:  This kit is used to upgrade a Manual Safety Pilot Kit (CPE-PO) to function using a 
switching device (remote control, bark chip switch, or wall switch).  Follow the Installation 
Instructions in the CPE-PO kit for proper installation and operation. 

 

 

USE THE PARTS LISTED BELOW WITH PARTS IN THE CPE-PO PILOT KIT  

 

PARTS INCLUDED IN 

SAFETY PILOT KIT 

LTHS 

CLC-BLOCK 

HEAT SHIELD INSTALLATION 

 

 

LATCHTAP KIT 
INSTALLED 

CLC-BLOCK 

N-6X1.5 

CPC-C 
SAFETY 
PILOT 
VALVE

 

(included 
in CPE-PO 

 

EMBER 
BURNER  

PILOT  
ASSEMBLY 

41S-6 

SC-1 

68-6 

49-6-6 

IMPORTANT:  GAS WILL NOT FLOW TO THE 
EMBER BURNER UNTIL THE LATCHTAP (CLC-
BLOCK) IS ENGAGED USING ONE OF THE 
SWITCHING DEVICES.

 

f i r e - p a r t s . c o m