Installer settings
In the standard menu, press the
Setup
button and then press the
Installer
button
Release by entering the code: 33
Use the arrow key to select the desired setting values
Takes you straight to the parameter groups
Selects all parameters
Select the values by touching the fields highlighted in white
The font colour of the parameters changes to red
Press the
+
and
-
buttons to set your desired values - the display flashes.
Press and hold the
+
and
-
buttons for to adjust the values quickly.
Confirm the set value with the green checkmark
10.1 Parametrising the heat circuits and HWT
Standard parameters (on the boiler control board):
• Heat circuit 1 (No. A1 - No. A9)
• Heat circuit 2 (No. A11 - No. A19)
• HWT 1 (No. B1 - No. B8)
Extension module 1 (HKM1):
• Heat circuit 3 (No. A21 - No. A29)
• Heat circuit 4 (No. A31 - No. A39)
• HWT 2 (No. B11 - No. B18)
Extension module 2 (HKM2):
• Heat circuit 5 (No. A41 - No. A49)
• Heat circuit 6 (No. A51 - No. A59)
• HWT 3 (No. B21 - No. B28)
Heat circuit board (HC A)
• Heat circuit A (No. A61 - No. A69)
• HWT A (No. B31 - No. B38)
The parameters of the heat circuits, HWTs, extension modules and the heat
circuit board are only displayed when hardware is connected.
HARGASSNER
Mo,25.11.18 08:19
Settings
Standard
Sweep
Auto
Function
Installer
You're now in the installer level.
Prior commissioning, all values must be checked
by the installer and set according to the
corresponding hydraulic scheme.
Short cut
Param.