Hardy Floor Scales
3
Temperature
Range
•
Operating -40º to +80º Degrees C (-40º to
+176º F)
•
Ambient -10 to +40 Degrees C (+14º to 104º
Degrees F)
Temperature
Effect
•
On Output - 0.0011% of load/Deg. C
•
On Zero - 0.0011% of FSO/Deg C
Cable Length
20 feet C2 Cable (6.096 meters)
NOTE:
To purchase additional C2 Cable, contact our local
Hardy Process Solutions Representative or Hardy
Service Center.
Materials of
Construction
Steel
•
Carbon Steel: Type A36 carbon plate steel (slip
resistance - tread or smooth surface)
•
Stainless Steel: Type 304 plate steel (slip resis-
tance - tread or smooth surface)
Paint
Two-part UV resistant Polyurethane - 2 to 4 mil
top coat - Carbon Steel only.
Note: Stainless Steel scales are not painted)
Foot
Elastomer
•
Natural Rubber (Standard)
Grade Level
In operation, the scale must be firmly and adequately
supported at all four corners to accommodate the
maximum load in your application. The scale must be
installed to within 3º of level.
Accessories
Ramps, Pit Frames, Bumper Guards, Lift Decks, Lift-
ing Eye Bolts, Bolt Down Plates
Anchor Bolt
Holds
1/2 inch bolts - 9/16” (.5625”) hole, 3.75 inches deep
5/8 inch bolts - 5/8” (.6250”) hole, 4.0 inches deep
•
NEMA Rating
Summing Junction Box Enclosure - NEMA 4 Stain-
less Steel
Summary of Contents for HIFS-3030-01-PS-S
Page 4: ......
Page 8: ...Hardy Floor Scales iv ...
Page 10: ...Hardy Floor Scales II ...
Page 53: ...Index Total Error 1 2 TROUBLESHOOTING 1 36 U UNPACKING 1 4 W welding 1 7 ...
Page 54: ...Hardy Floor Scales ...