98
Chapter
5
•
•
•
•
•
•
On the
HI 6500 series instrument display
, select the FILTER menu and use the UP or
DOWN button to select WAVERSAVER menu item. The current value will be displayed.
If the WAVERSAVER selection needs to be modified, press the ENTER key, then use the
UP and DOWN buttons to select a new value and press the ENTER button to set and save
the new WAVERSAVER setting.
WAV Options: Variation Threshold and Motion Threshold
(HI 6500-XP and HI 6510-XP only)
WAV is a superset of WAVERSAVER that uses two entirely new parameters,
Variation Threshold and Motion Threshold. These two parameters add a patent-pending
adaptive filtering algorithm to the WAVERSAVER output that provides stability to weight
readings of up to 1:30,000.
On the
web page:
configure WAV by first setting the WAVERSAVER and
Numaverages parameters to establish the speed and required accuracy for dynamic
weighing. Set the Variation Threshold 0.0 and observe the peak to peak variation of the
weight value. Then set the variation threshold parameter to be 1.5 times larger than the
observed weight variation. Set the Motion Threshold to 1/3 of the observed peak to peak
weight variation.
For example, if the observed weight change is 6, set the Variation Threshold should be set
to 9 (1.5X) and the Motion Threshold parameter set to 2 (1/3X). Note that he weight
changes will settle to a 2 increment level.
Weight changes smaller than 1:30,000 will need considerations for environmental
protections from air movement forces and additional WAVERSAVER and NumAverages
settings.
The default factory setting is 0.0; which turns WAV OFF
Summary of Contents for HI 6500 Series
Page 10: ...viii Contents ...
Page 20: ...10 Chapter 2 ...
Page 72: ...62 Chapter 4 ...
Page 96: ...86 Chapter 5 Profibus DP Commands and Parameters ...
Page 97: ...Instrument Configuration 87 Serial Option Termination ...
Page 126: ...116 Chapter 5 ...
Page 156: ...146 Chapter 8 ...
Page 163: ...Troubleshooting 153 General Troubleshooting Flow Chart Index ...
Page 164: ...154 Chapter 9 A Guideline Instability Electrical and Mechanical review ...
Page 165: ...Troubleshooting 155 A1 Checking for Unstable Components in a Weighing System ...
Page 166: ...156 Chapter 9 B Guidelines for Electrical Mechanical or Configuration Issues ...
Page 167: ...Troubleshooting 157 B1 Guidelines to Verify Electrical Installation ...
Page 168: ...158 Chapter 9 B2 Guidelines to Verify Mechanical Installation ...
Page 170: ...160 Chapter 9 C Integrated Technician and Stability Test Overview ...
Page 171: ...Troubleshooting 161 E Testing for Non Return to Zero System with IT Summing Card ...
Page 173: ...Troubleshooting 163 G Calibration Errors When Performing the Calibration ...
Page 174: ...164 Chapter 9 H Mechanical Installation ...
Page 175: ...Troubleshooting 165 J Electrical Inspection ...
Page 176: ...166 Chapter 9 K Installation Check Points ...
Page 177: ...Troubleshooting 167 M Weight Processor s Front Display is Blank or Locked ...
Page 178: ...168 Chapter 9 N Analog Out HI 6510 Only ...
Page 194: ...184 Appendix A Figure D1 Assembling the Swivel Mount Enclosure on the instrument pedestal ...
Page 196: ...186 Appendix A Dimensions ...
Page 200: ...4 HI 6500 Series USER GUIDE Index ...
Page 201: ......