Chapter 3 - Installation
3-7
FIG. 3-6 MODULE WITH DOOR OPEN
Step 2.
Install the cable and connector so it allows
the module door to be shut.
Step 3.
There is a bracket (not shown) that allows
you to use a tie wrap to secure the cable to
the module.
Step 4.
With the plug oriented correctly (See the
pin-out diagram above), plug the I/O male
connector into the I/O connector at the
front of the module.
Step 5.
Check to be sure that the connector is
completely plugged in before operating
the module.
NOTE:
Most of the problems with modules are due to loose
connections. Be sure to check the I/O connection first
in the event you have a problem receiving information
from the load cells or if the relays do not operate cor-
rectly.
Load Cell Wiring
Diagrams
NOTE:
The HI 1746 has two factory installed jumpers. If
your application is not using C2 load cells do not
remove the factory installed jumpers . If your appli-
Summary of Contents for C Series
Page 8: ...HI 1746 WS WEIGHT SCALE MODULE vi...
Page 10: ...HI 1746 WS WEIGH SCALE MODULE II...
Page 46: ...HI 1746 WS WEIGH SCALE MODULE 4 16 I O Setup Ladder Logic for Remote Mode Operation...
Page 47: ...Chapter 4 Setup 4 17...
Page 54: ...HI 1746 WS WEIGH SCALE MODULE 4 24 SETPARAMS Remote Mode of Operation...
Page 55: ...Chapter 4 Setup 4 25...
Page 56: ...HI 1746 WS WEIGH SCALE MODULE 4 26...
Page 60: ...HI 1746 WS WEIGH SCALE MODULE 4 30...
Page 69: ...Chapter 5 Calibration 5 9...
Page 70: ...HI 1746 WS WEIGH SCALE MODULE 5 10 FIG 5 5 C2 LADDER LOGIC EXAMPLE LOCAL MODE OF OPERATION...
Page 74: ...HI 1746 WS WEIGH SCALE MODULE 5 14...
Page 84: ...HI 1746 WS WEIGH SCALE MODULE 6 10...
Page 92: ...HI 1756 WS MANUAL...