Chapter 2 - Specifications
2-1
CHAPTER 2 - SPECIFICATIONS
A Brief Description of
Chapter 2
Chapter 2 lists the specifications for the HI 1746-WS
Weigh Scale Module. Specifications are listed for the
standard instrument and for optional equipment. The
specifications listed are designed to assist in the
installation, operation and troubleshooting of the
instrument. All service personnel should be familiar
with this section before attempting an installation or
repair of this instrument.
Specifications for a
Standard HI 1746-WS
Weigh Scale Module
Modes of
Operation
Local and Remote
Conversion Rate
20 updates per second
Averages
1-255 User Selectable in single increments
Resolution
Displayed:
1:985,000 (@ 3 mV/V)
1:656,000 (@ 2 mV/V)
Internal:
1:1,048,576
Input
Up to eight (8) 350 ohm Full Wheatstone Bridge,
Strain Gauge Load Sensors/Cells (5 volt excitation)
on one vessel.
Non-Linearity
0.0015% of Full Scale
Maximum Zero
Tolerance
32766
WAVERSAVER
®
User Selectable
•
7.50 Hz
•
3.50 Hz
•
1.00 Hz (Default)
•
0.50 Hz
•
0.25 Hz
Excitation Monitor
Current less than +/- 10% expected
Summary of Contents for C Series
Page 8: ...HI 1746 WS WEIGHT SCALE MODULE vi...
Page 10: ...HI 1746 WS WEIGH SCALE MODULE II...
Page 46: ...HI 1746 WS WEIGH SCALE MODULE 4 16 I O Setup Ladder Logic for Remote Mode Operation...
Page 47: ...Chapter 4 Setup 4 17...
Page 54: ...HI 1746 WS WEIGH SCALE MODULE 4 24 SETPARAMS Remote Mode of Operation...
Page 55: ...Chapter 4 Setup 4 25...
Page 56: ...HI 1746 WS WEIGH SCALE MODULE 4 26...
Page 60: ...HI 1746 WS WEIGH SCALE MODULE 4 30...
Page 69: ...Chapter 5 Calibration 5 9...
Page 70: ...HI 1746 WS WEIGH SCALE MODULE 5 10 FIG 5 5 C2 LADDER LOGIC EXAMPLE LOCAL MODE OF OPERATION...
Page 74: ...HI 1746 WS WEIGH SCALE MODULE 5 14...
Page 84: ...HI 1746 WS WEIGH SCALE MODULE 6 10...
Page 92: ...HI 1756 WS MANUAL...