Chapter 6 - Operating Procedures
6-1
CHAPTER 6 - OPERATING PROCEDURES
A Brief Description of
Chapter 6
Chapter 6 covers the operation of the HI 1756 (-WS
and -2WS) Weigh Scale Modules. The Operating Pro-
cedures include Reading data transferred to the PLC
from the weigh scale module. (See Fig. 6-1)
FIG. 6-1 COMMUNICATION
CONFIGURATION DIALOG BOX
Input Data
This is the discrete input data which is in module
defined data type, LOCAL:X:I (where X is the slot
number). (See Fig. 6-2)
#0*
Bits 15-0: STATUSWORD for Channel 0
Bits 31-16: STATUSWORD for Channel 1
#1
Gross Weight:
5
#2
Net Weight:
6
#3
Rate of Change:
7
#4
loadcellcurrent (milliamps):
8
#9, #10
TimeStamp
NOTE:
The TimeStamp is a 64 bit integer, giving the system
time in microseconds