Chapter 4 - Setup
4-15
Error Return Values:
•
STATUSWORD - there was a conversion error,
weight in motion or an A/D error or all three.
•
C2FAILNODEVS - detected no C2 load cells.
•
C2FAILCAPEQ - detected two load cells with
different capacities.
Read Weight Cal
Command
(
READWEIGHTCAL
)
Weight data at calibration points are saved. The Read
Weight Cal Command reads in the values, letting you
compare raw counts at current input and counts at cal-
ibration points to ensure the the scale is returning cor-
rect input from each calibration point before running
new calibration command.
Command Number: 0x63 (Hexadecimal)
Channel Number: 0 or 1
Number of Elements: 8
Return Values:
Command (DINT)
Channel (DINT)
Status (DINT)
Zero counts (DINT)
Cal zero counts (DINT)
Cal low counts (DINT)
Cal high counts (DINT)
CalibK (weight per count) (REAL)
ADC (as of the time the command is given) (DINT)
Perform Integrated
Technician Tests
(WEIGHSYSTEST)
Performs the Integrated Technician tests.
Command Number: 0x6D (Hexadecimal)
Channel Number: 0 or 1
Number of Elements: 16
Status
nSensors: Number of Sensors.