If damage or malfunction is detected, the device should be taken out of service and handed over for repair to
the manufacturer's facility or another entity authorized by the manufacturer.
3.2 Application
WARNING:
USE THE DEVICE ONLY FOR ITS INTENDED PURPOSE. INCORRECT USE MAY
ADVERSELY AFFECT ITS SAFETY AND FUNCTIONING.
WARNING:
THE DEVICE MAY BE USED IN POTENTIALLY EXPLOSIVE ATMOSPHERES ONLY
AS DEFINED IN THIS MANUAL AND RESULTING FROM THE EX FEATURE ON THE DATA
PLATE.
OptiLine series luminaires are designed for use:
•
In accordance with the environmental and technical conditions specified in this manual and on the nameplate.
•
In external and/or internal installations;
•
In Zone 2 of explosion hazard of gases, vapours and mists of flammable liquids classified as explosion group
IIA, IIB or IIC and temperature class T1-T4;
•
In Zones 21, 22 explosion hazard of flammable fibres of explosive groups IIIA, IIIB, IIIC, whose assumed flash
point is higher than 105°C and the smouldering temperature of the dust layer (5mm) higher than 145°C.
3.3 Other conditions for safe use
•
The luminaires are suitable for fixed installations only;
•
Operation of the luminaire outside the designated ambient temperature range is unacceptable and will lead to
faster wear and/or damage. At the same time, it causes the loss of the manufacturer's warranty. Note: The use
of a luminaire outside the designated range of ambient temperatures may result in loss of explosion safety
measures, e.g., exceeding the temperature class and explosion;
•
Each luminaire has a warning plate:
“DO NOT OPEN WHEN ENERGIZED”;
•
The housing body is made of glass fibre reinforced polyester (GRP), while the diffuser is made of polycarbonate
(PC), so they should not be exposed to chemicals that may damage them, in particular: oil, acetone, chlorine,
ethyl, ether, solvents;
•
The luminaire has a degree of photobiological hazard RG1
– do not stare at the working light source;
•
Risk of electric shock, take the required precautions, in particular do not open the live luminaire.
4.
TRANSPORT AND STORAGE
Transport of luminaires should be carried out in original unit packaging. Unit and/or bulk packaging should be protected
against precipitation during transport.
Luminaires can only be stored in covered rooms at a temperature of +5ºC to +35ºC and humidity of less than 75%.
The premises should be free of corrosive vapours and gases.
5.
INSTALLATION
5.1 Before installation
•
Make sure that the packaging has not been damaged during transport;
•
Unpack the device;
•
Remove any packaging elements that could be dangerous to humans, such as belts, plastic bags, etc.