If damage or malfunction is detected, the device should be taken out of service and handed over for repair to 
the manufacturer's facility or another entity authorized by the manufacturer. 
 

 

3.2 Application 

 

 

WARNING: 

USE THE DEVICE ONLY FOR ITS INTENDED PURPOSE.  INCORRECT USE MAY 

ADVERSELY AFFECT ITS SAFETY AND FUNCTIONING.

 

 

 

WARNING: 

THE DEVICE MAY BE USED IN POTENTIALLY EXPLOSIVE ATMOSPHERES ONLY 

AS  DEFINED  IN  THIS  MANUAL  AND  RESULTING  FROM  THE  EX  FEATURE  ON  THE  DATA 
PLATE. 

 

OptiLine series luminaires are designed for use: 

 

 

In accordance with the environmental and technical conditions specified in this manual and on the nameplate. 

 

In external and/or internal installations; 

 

In Zone 2 of explosion hazard of gases, vapours and mists of flammable liquids classified as explosion group 
IIA, IIB or IIC and temperature class T1-T4; 

 

In Zones 21, 22 explosion hazard of flammable fibres of explosive groups IIIA, IIIB, IIIC, whose assumed flash 
point is higher than 105°C and the smouldering temperature of the dust layer (5mm) higher than 145°C. 

3.3 Other conditions for safe use 

 

 

The luminaires are suitable for fixed installations only; 

 

Operation of the luminaire outside the designated ambient temperature range is unacceptable and will lead to 
faster wear and/or damage. At the same time, it causes the loss of the manufacturer's warranty. Note: The use 
of  a  luminaire  outside  the  designated  range  of  ambient  temperatures  may  result  in  loss  of  explosion  safety 
measures, e.g., exceeding the temperature class and explosion; 

 

Each luminaire has a warning plate: 

“DO NOT OPEN WHEN ENERGIZED”;

 

 

The housing body is made of glass fibre reinforced polyester (GRP), while the diffuser is made of polycarbonate 
(PC), so they should not be exposed to chemicals that may damage them, in particular: oil, acetone, chlorine, 
ethyl, ether, solvents;  

 

The luminaire has a degree of photobiological hazard RG1 

– do not stare at the working light source; 

 

Risk of electric shock, take the required precautions, in particular do not open the live luminaire. 

 

4. 

TRANSPORT AND STORAGE  

 

Transport of luminaires should be carried out in original unit packaging. Unit and/or bulk packaging should be protected 
against precipitation during transport.   
Luminaires can only be stored in covered rooms at a temperature of +5ºC to +35ºC and humidity of less than 75%.                   
The premises should be free of corrosive vapours and gases. 
 

5. 

INSTALLATION 

5.1 Before installation 

 

 

Make sure that the packaging has not been damaged during transport; 

 

Unpack the device; 

 

Remove any packaging elements that could be dangerous to humans, such as belts, plastic bags, etc. 

 
 
 

Summary of Contents for OptiLine A1 Series

Page 1: ...1 z 16 USE AND MAINTENANCE INSTRUCTION OF LIGHTING FIXTURE OptiLine A1 SERIES Instruction no K 26190 PW 0006 HARDO Czapski i Wsp lnicy Sp j Release date 04 04 2024 ul Spacerowa 5 Issue no 1 3 32 083...

Page 2: ...n 7 5 2 Installation 8 5 3 Electrical connection 10 5 3 1 General requirements 10 5 3 2 Execution of luminaire electrical connections 10 6 WORK IN EMERGENCY MODE 11 6 1 General information 11 6 2 Batt...

Page 3: ...ements of the IECEx system Detailed guidance on potentially explosive atmospheres is given in this document Luminaires are approved for use in both external and internal installations The external hou...

Page 4: ...50Hz In emergency mode they are powered from a built in Ni Cd battery pack ensuring backup in emergency mode of not less than 1 5 hours A detailed description of the possible configurations and their...

Page 5: ...log card of the OptiLine lighting fixture 2 2 Ex marking Depending on the version OptiLine series luminaires are marked with Ex features as follow II 3G Ex ec IIC T4 Gc II 2D Ex tb IIIC T70 C Db The i...

Page 6: ...s a high level of safety and which will not become a source of ignition under normal conditions of use and during expected damage 3 SAFETY 3 1 General precautions DANGER THE EXPLOSION HAZARD CAUSED BY...

Page 7: ...t temperature range is unacceptable and will lead to faster wear and or damage At the same time it causes the loss of the manufacturer s warranty Note The use of a luminaire outside the designated ran...

Page 8: ...the GRP lower body At the place where the nuts are mounted the mounting brackets must be fixed with M8 15 mm bolts and M8 spring washers M8 screws should be tightened with a torque of 9 10 Nm Install...

Page 9: ...Strona 9 z 16 Figure 3 Acceptable mounting position...

Page 10: ...5 4 mm2 for luminaires powered on one side Single core cross section 2 5 4 mm2 for pass through or crossed powered luminaires Outer diameter of the cable 8 17 mm the value depends on the size and type...

Page 11: ...ts for emergency lighting OptiLine luminaires A1 have implemented Built in automatic functional test execution Functional tests last one minute and are performed first 1 hour after the first start nex...

Page 12: ...the capacitance test performed at least once every 52 weeks WARNING ALL REPAIRS INCLUDING REPLACEMENT OF THE LIGHT SOURCE OR BATTERY PACK CAN ONLY BE CARRIED OUT USING ORIGINAL SPARE PARTS AND ONLY BY...

Page 13: ...At least once every 1 months a visual and close inspection of the lighting fixture should be carried out During the visual inspection luminaires do not need to be disconnected from the power source Th...

Page 14: ...OSIVE ATMOSPHERE In accordance with the requirements of local regulations electrical tests related to Measurement of the current consumed by the luminaire Measurement of the condition of the insulatio...

Page 15: ...2 2 Photometric data Photometric data for OptiLine A1 for an ambient temperature of 25 C a bar temperature of 4000K and a colour rendering index CRI 80 are shown in Table 3 Type Luminous flux with AC...

Page 16: ...dimensions of OptiLine luminaires are shown in Figure 5 and Table 5 Figure 5 Basic dimensions of OptiLine luminaires Type L L1 B H OptiLine 60 670 400 173 107 OptiLine 12 1276 800 173 107 Table 5 Bas...

Reviews: