4 - System setup
28
Manual System Setup
The AutoHeight system will not operate in automatic mode until the system has been completely configured by either the
Automatic System Setup or Manual System Setup. It is recommended that the Automatic System Setup be used, but if
necessary a manual system setup may be used. The manual system setup involves setting up each sensor (programming
serial numbers and sensor locations) as well as tuning the hydraulic parameters manually.
Setting Up Sensors
Before beginning, it is necessary to know the serial number (A/B) and
location for each of the sensors. The sensor serial number is located on
the bottom of the sensor housing, beside the foam disc.
÷
NOTE! The location of serial numbers may differ from sensor to
sensor. Some sensors have the serial number located at position
(A), and others at position (B).
It is recommended that you record the serial numbers according to
sensor locations in the figure because this information may be required
during troubleshooting.
The left channel menu prompts are described in Table 3. For the other channels, the basic structure and behaviour of the
prompts are the same. Navigate with Sensor display/Setup switch.
Table 3 - Left Channel SENSOR DISPLAY Menus
Entering Sensor Serial Numbers
To enter a sensor serial number in one of the boom locations:
1.
Ensure the AutoHeight panel is in MANUAL mode, at the run screen.
2.
Navigate to the "
More ?
" menu prompt in the SENSOR DISPLAY menu. Toggle "AUTO (YES)" to confirm.
Sensor position Sensor serial number
A
B
C
D
E
Navigating past the end of the menu will return the panel to the Sensor…"
More
" Menu
LIht 108
Current height reading of the
LI
sensor is 108 cm.
LI 11070
Serial number 11070 is installed as the left inner (
LI
) sensor.
LOht 115
Current height reading of the
LO
sensor is 115 cm.
LO 11069
Serial number 11069 is installed as the left outer (
LO
) sensor.
Navigating past the end of the menu will return the panel to the Sensor…"
More
" Menu
11069
A
B
Summary of Contents for AutoHeight
Page 5: ...5 1 Declaration This page is intentionally left blank ...
Page 6: ...1 Declaration 6 ...
Page 22: ...3 Description 22 ...
Page 46: ...5 Operation 46 ...
Page 50: ...6 Maintenance 50 ...
Page 58: ...8 Technical specifications 58 ...
Page 60: ...9 Index 60 ...
Page 62: ...HARDI INTERNATIONAL A S Helgeshøj Allé 38 DK 2630 Taastrup DENMARK ...