background image

1

HARDI PILOT
3570 Monitor

675044-GB-96/9

HARDI INTERNATIONAL A/S reserve the right to make changes in design
or to add new features without any obligation in relation to implements
purchased before or after such changes.

Contents

EC Declaration of Conformity ......................................................... 2
Operator safety ............................................................................... 3
Description ...................................................................................... 4
Components .................................................................................... 5
Connection of HP 3570 display ....................................................... 6
Display readout information ............................................................ 7
Menus ............................................................................................. 9

Using the keyboard ................................................................... 9
Keystroke menu tree chart for HP 3570 version 1.5 ............... 10
[ 01 ] Flow calibration - theoretical .......................................... 11
[ 02 ] Flow calibration - Tank method ...................................... 12
[ 03 ] Flow calibration - Nozzle method ................................... 13
[ 04 ] Speed calibration -theoretical ........................................ 14
[ 05 ] Speed calibration - practical ........................................... 15
[ 06 ] Regulation constant ....................................................... 15
[ 07 ] Revolutions readout of P.T.O. ......................................... 16
[ 08 ] Selection of unit (liquid or solid matter) .......................... 17
[ 09 ] Adjustment of work width ............................................... 18
[ 10 ] Location of speed transducer ......................................... 19
[ 11 ] HARDI LINK ................................................................... 20
Areameter and HP 3570 ......................................................... 20
Mistblower and HP 3570 ......................................................... 21
Storage ................................................................................... 21

Fault finding .................................................................................. 21

Error codes during start-up ..................................................... 21
Fuse replacement in HP 3010 tractor junction box ................. 22
Coaxial cables and short circuits ............................................ 22
Fine tuning the flow constant - PPU ........................................ 22
Testing flow transducer (ref. no. 728816) ................................ 23
Testing speed transducer (ref. no. 729058) ............................ 23

Technical specifications ................................................................ 24
Assembly ...................................................................................... 25
Chart for recording values ............................................................. 31
Spare parts ................................................................................... 33

Summary of Contents for 3570

Page 1: ...method 12 03 Flow calibration Nozzle method 13 04 Speed calibration theoretical 14 05 Speed calibration practical 15 06 Regulation constant 15 07 Revolutions readout of P T O 16 08 Selection of unit liquid or solid matter 17 09 Adjustment of work width 18 10 Location of speed transducer 19 11 HARDI LINK 20 Areameter and HP 3570 20 Mistblower and HP 3570 21 Storage 21 Fault finding 21 Error codes d...

Page 2: ...K Importer declare that the following product Adhere extra shipping package labels to inside cover was manufactured in conformity with the provisions in the EMC direc tive 89 336 EEC EN 50081 1 generic emission and EN 50082 1 generic immunity Taastrup 1 9 96 Erik Holst Managing Director HARDI INTERNATIONAL A S ...

Page 3: ...side of your finger Avoid using your fingernail If an arc welder is used on the equipment or anything connected to the equipment disconnect power before welding Do not service or repair the equipment whilst it is operating Test with clean water prior to filling with chemicals Always replace all safety devices covers or shields immediately after servicing Keep children away from the equipment Do no...

Page 4: ... for easy placement in the tractor cabin and can be fitted directly on to a flat surface It is illuminated internally so readout is possible even for night time work HP 3570 can have the following readouts Driving speed Area treated Revolutions Actual application rate Flow rate The HP 3010 tractor junction box is fitted to the tractor It supplies HARDI LINK with current and has the connection poin...

Page 5: ...ve been developed to last many years under agricul tural conditions Components 1 HP 3570 display 2 HP 3010 tractor junction box 3 Fuse 4 Speed transducer 5 Magnets 6 Flow transducer 7 Diode 8 Rotor 9 Flow housing for operating unit 10 Coaxial cable 11 Power cable 12 BNC connector jack 13 BNC connector plug 14 BNC cover not used 15 Plug socket for flow transducer 1 2 3 4 10 5 6 7 8 9 12 12 13 14 15...

Page 6: ...t the internal electronics are also tested When the test is concluded all symbols light up briefly after which everything is switched off and a version number is shown The version number explains which programme version the display unit contains HP 3570 concludes the test by showing the total work boom width and the number of sections which is one for this equipment HP 3570 is now tested and is re...

Page 7: ...tractor See Menus 1 0 1 0 Location of speed trans ducer Speeds under 0 5 km 0 3 mph per hour are shown as 0 0 The travelling speed is updated at least twice a second Reading area treated The area display shows a summation of the area treated The area display calculates as long as there is simultaneous speed and flow or alternatively speed and a signal from the areameter The area is shown up to 999...

Page 8: ... last reset will be shown in the display NOTE The total area treated and total volume sprayed is updated in the non volatile memory for every 0 5 hectares 1 acre The display can show a maximum of 9999 units sprayed If this is exceeded L L G G and will be shown Reset of total area treated and total volume sprayed Area and volume sprayed can be reset by pressing the accept key continually After appr...

Page 9: ...he menus can be scrolled to and fro with the arrow keys When the chosen menu is shown on the display press the menu key for more than 3 seconds to open the menu The display will then change to a new picture so further selections can be made between different set ups or parameters When modifying a parameter pro longed pressure on the arrow key will cause the data shown on the display to alter faste...

Page 10: ...low practical Nozzle 04 Speed theoretical 05 Speed practical 06 Reg Constant 07 r min choice 08 Unit 09 Work width 10 Location of speed transducer 11 HARDI LINK NO SAVE NO SAVE Keystroke menu tree chart for HP 3570 version 1 5 Press more than 3 seconds ...

Page 11: ...alibration theoretical During theoretical flow calibration in menu 01 the number of pulses per unit P P U P P U are shown on the display For example L 120 0 L 120 0 indicates the number of pulses which theoretically come from the flow transducer whilst 1 litre of liquid passes through Method 1 Open menu 01 2 Use arrow key to adjust PPU value 3 Use accept key to close the menu and return to the mai...

Page 12: ...ches a unique mark on the tank contents level indicator e g 1000 litre 300 gallons 2 Open all boom sections 3 Open menu 02 and turn the main ON OFF valve on Open All Open All will be displayed if there is no flow The display unit will then begin to count the volume being emptied through the nozzles 4 When for example 600 litre 200 gallons have been emptied out as shown by the tank contents level i...

Page 13: ...of nozzles to spray 3 Turn the main ON OFF valve on Open All Open All will be displayed if the main valve is turned off 4 The display unit will then show the individual nozzle output per minute 5 Using a HARDI calibration jug check the actual nozzle output per minute It is recommended that an average of several nozzles be taken 6 Correct the output shown on the display with the arrow key to read t...

Page 14: ...ses per rotation Method 1 Open menu 04 2 n n indicates number of magnets and this is corrected with the arrow key to read the actual number of magnets Press the accept key 3 r r indicates radius The radius is measured from the earth up to the middle of the hub cap The wheel radius is corrected with the arrow key to read the actual measured radius Keystrokes 04 HARDI PILOT HARDI tHEO 04 Set HARDI P...

Page 15: ...eld with a half full tank and normal working tyre pressure in order to obtain the wheel s real working radius Method 1 Measure a distance not less than 75 metres 250 feet 2 Park the tractor at the start of the measured distance 3 Open menu 05 Drive the measured distance 4 Correct the distance shown on the display with the arrow key to read the actual distance Keystrokes 06 Regulation constant Not ...

Page 16: ...evant to this system Method 1 Open menu 07 2 Choose the PTO symbol with the arrow key and press accept key 3 Now a value of 1 0 1 0 is shown This indicates that one pulse will come per revolution If the revolutions for example on a fertiliser disc are required it is necessary to alter the pulse number per shaft revolution with the arrow key to get disc revolutions Keystrokes 07 HARDI PILOT HARDI 0...

Page 17: ... predisposed as a monitor for spreading fertiliser and it is therefore possible to choose between dosage of liquid or solid matter Method 1 Open menu 08 2 Use the arrow key to choose the unit Keystrokes 08 HARDI PILOT HARDI Unıt 08 Set HARDI PILOT HARDI Set L ...

Page 18: ...idth Correct total work width is necessary to calculate dosage and area covered Method 1 Open menu 09 2 Use the arrow key to increase or decrease work width Keystrokes 09 HARDI PILOT HARDI 512E 09 Set HARDI PILOT HARDI 1200 Set ...

Page 19: ...nsducer signal is coming from the sprayer The transducer location must be on trct trct otherwise there will be no speed readout NOTE Do not confuse the abbreviation for transducer t r d t r d with trct trct Method 1 Open menu 10 2 Use the arrow key to select trct trct Keystrokes 10 HARDI PILOT HARDI 10 Set trd HARDI PILOT HARDI trd trct Set ...

Page 20: ...ow key to choose Y e s Y e s Keystrokes 11 HARDI PILOT HARDI nEt 11 Set HARDI PILOT HARDI End nEt OF yES Set Areameter and HP 3570 Points to note if the system is fitted with an areameter The system will register covered area when the south side of the magnet is located directly in front of the areameter transducer When the system is used with a flow transducer the areameter must be disabled This ...

Page 21: ...ng start up At start up the following error codes may be shown LINE FAIL LINE FAIL This indicates that the unit can see signals on HARDI LINK but cannot interpret them Action Check the system is correctly terminated See Menu 1 1 1 1 HARDI LINK When this check is finished re start the system No data No data This means that there is no signal on HARDI LINK Action Check all the coaxial cable connecti...

Page 22: ...ssible replace the whole cable Fine tuning the flow constant PPU Calibration of the flowmeter is carried out with clean water but small changes may occur when adding pesticides or fertiliser This will effect the final readings This is typically noted when the volume displayed on the display does not equal the actual known volume that was sprayed out The below formula can be used to fine tune the f...

Page 23: ... to negative of battery 5 Set multimeter to DC volt 6 By turning the mill wheel slowly this will register approx 8 0 1 volt with the diode on and 0 3 0 1 volt with the diode off with every second magnet Testing speed transducer ref no 729058 Wire connections BROWN wire to positive of 12 volt battery BLACK wire to negative BLUE wire to multimeter 1 Connect negative from multimeter to negative of ba...

Page 24: ...Volt Maximum peak 16 Volt Fuse 4 0 Amp Ø 6 5 x 32 F Quick acting Ambient temperature 20 C to 50 C Update from all transducers 4 times per second Update of non volatile memory every 0 5 ha Chart showing when treated area is registered SPEED FLOW AREA SPEED UPDATE UPDATE FLOW UPDATE AREA UPDATE ...

Page 25: ... transducer cut cable approx 30 cm from connectors and fit plug and socket Brown wire is positive Blue wire is negative Fuse 4 0 Amp Ø 6 5 x 32 F Quick acting HARDI ref no 261617 It is recommended that the power supply should come directly from the battery If desired the power supply may come via the ignition key of the vehicle An on off switch can be fitted over the jumper connection if this is d...

Page 26: ...ay The display can fixed to a flat surface with the supplied Velcro tape Power must be disconnected before attaching the BNC connector plug to the display connector jack The connector has a bayonet fitting To attach locate guide groove push and turn Transducer wire colour code Wire colour Connection for transducer Brown 12 Volt supply Black GND Blue Signal ...

Page 27: ...of magnets fitted are as follows Tractor front wheel rim size up to 20 4 Tractor rear wheel rim size over 20 6 Transmission driveshaft 1 The south side of the magnet must face the transducer Distance between them must be 5 to 7 mm Flow transducer for BK operating unit For BK operating unit a mounting set is available HARDI ref no 833696 1 Disconnect hoses 5 7 mm N S 4 5 mm ...

Page 28: ...ied 3 Remove the distribution valves and replace the threaded rod with the shorter one 213 mm 4 Fit HARDI MATIC with metal support bracket and filter Bolt bracket to rack arm Fit elbow and end cover with O ring for the rod washer and nut 5 Bolt the upper rack arm ...

Page 29: ...nect as shown 7 Assemble the distribu tion valves The end cover must have the ribs facing outwards Assembly order is O ring bushing disc and nut Remember the new seals 8 Shorten hose to 80 mm and connect Insert the flow transducer into the housing ...

Page 30: ...istribution valves 3 Attach distribution valves with flow housing with the ball seat on the end to main ON OFF valve unit 4 Flow transducer is fitted to the housing and connected to HP 3010 via the a 3 poled plug P T O transducer and areameter The south side of the magnet must face the transducer Distance between them must be 5 to 7 mm An adjustable hose clamp drilled with a 4 5 mm hole can be use...

Page 31: ...e should be put into the waste collection system Polyethylene Can be recycled When the HARDI PILOT has completed its working life it must be thoroughly cleaned The synthetic fittings can be incinerated The printed circuit boards and metallic parts can be scrapped Chart for recording values Menu Function 1 Values 2 Values 3 Values Nozzles colorus 01 Flow PPU 04 Speed Number of magnets Wheel radius ...

Page 32: ... Flow practical Tank 03 Flow practical Nozzle 04 Speed theoretical 05 Speed practical 06 Reg Constant 07 r min choice 08 Unit 09 Work width 10 Location of speed transducer 11 HARDI LINK NO SAVE NO SAVE Press more than 3 seconds ...

Page 33: ...33 ...

Page 34: ...34 ...

Page 35: ...35 ...

Page 36: ...36 ...

Reviews: