Page 4
For technical questions, please call 1-888-866-5797.
Item 63323
Pump
Cord
Float
Switch
Cord
Sewage Cover
Sewage Cover
Vent
Vent
Float
Float
Switch
Switch
Pump
Pump
Figure B: Pump Position
4. Attach a discharge pipe to the Pump Outlet.
Note:
Wrap all threaded connections
with PTFE thread seal tape.
5. Check Valve is sold separately. Install
according to manufacturer instructions.
6. To prevent excessive cycling from backflow of water,
install a check valve onto the discharge pipe. This
prevents water from flowing back after the pump
shuts off. Mount the check valve according to check
valve label to avoid the valve flapper getting stuck.
To main waste line
To main waste line
(sewer or septic tank)
(sewer or septic tank)
GFCI-
Protected
Receptacle
Float
Switch
Cord
Pump Cord
Vent
Check
Valve
Pump
Pump
Outlet
Outlet
1
1
/
/
8
8
Ǝ
Ǝ
Air
Air
Bleed
Bleed
Hole
Hole
Discharge
Discharge
Pipe
Pipe
Figure C: Outlet Pipe and Plug
IMPORTANT:
Drill a
1
/
8
Ǝ
diameter air bleed hole
through the Discharge Pipe just above the lower Base
WRSUHYHQW3XPSƎDLUORFNƎ$VPDOOVSUD\RIZDWHURXW
of this hole is normal while the Pump is running.
7. Connect additional Discharge Pipe as needed to
direct the discharge to the main waste line for the
sewer or septic tank. The discharge should be kept
as short as possible with a minimum number of turns.
IMPORTANT: Do not exceed the
Maximum Head Lift @ 0 Flow of the Pump.
Operation
After reading these instructions, consider the following points before starting the pump:
1. Verify that the pump rests on the floor of the basin.
2. Verify that the discharge pipe is properly connected.
3. Verify that the electrical connection
is 120 VAC, 60 Hz.
4. Verify that the electrical socket is GFCI
protected and in good condition. Test
GFCI protected outlet before use.
5. Verify that water and moisture cannot
get near the power supply socket.
6. Verify that the pump is installed so
as to prevent running dry.
Maintenance
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION:
Unplug the Pump from its electrical outlet before performing any
inspection, maintenance, or cleaning procedures.
If the pump is moved during operation, flush it out with clean water after every use.