After reading these instructions, consider the following points before starting the pump:

1.  Verify that the pump rests on the floor of the basin, 

if it is not suspended by the handle.

2.  Verify that the discharge pipe is properly connected.

3.  Verify that the electrical connection 

is 120 VAC, 60 Hz.

4.  Verify that the electrical socket is GFCI 

protected and in good condition. Test 
GFCI protected outlet before use.

5.  Verify that water and moisture cannot 

get near the power supply socket.

6.  Verify that the pump is installed so 

as to prevent running dry.

Summary of Contents for creekstone 63313

Page 1: ...ture reference When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2016 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this ...

Page 2: ...ump plug or receptacle getting wet position pump to one side of a wall mounted receptacle to prevent water from dripping onto the receptacle or plug The user should arrange a drip loop in the cord connecting the pump to a receptacle Pump The drip loop is that part of the cord below the level of the receptacle or the connector if an extension cord is used to prevent water traveling along the cord a...

Page 3: ... Pump will not function unless fully submerged Power Supply 1 The pump is equipped with a shock proof plug according to regulations The pump is designed to be connected to 120 VAC 60 Hz GFCI protected socket 2 Make sure that the socket is sufficiently secured and is in excellent condition 3 WARNING To prevent death from electric shock pump must be connected only to a GFCI protected outlet WARNING ...

Page 4: ...f the basin if it is not suspended by the handle 2 Verify that the discharge pipe is properly connected 3 Verify that the electrical connection is 120 VAC 60 Hz 4 Verify that the electrical socket is GFCI protected and in good condition Test GFCI protected outlet before use 5 Verify that water and moisture cannot get near the power supply socket 6 Verify that the pump is installed so as to prevent...

Page 5: ...3 Low line voltage 4 Check valve sold separately stuck or installed backwards 1 Remove Inlet Screen Clean out dirt and debris from Inlet Screen and impeller Then replace Inlet Screen 2 There must be at least 0 deep water for the Pump to operate properly 3 Consult an electrician 4 Remove and examine check valve Pump won t start or run 1 Check power connections and circuits fuses 2 Water level too l...

Page 6: ...G OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Parts List Part Description Qty 1 Front Cover 1 2 Filter 1 3 Water Seating 1 4 Impeller Head 1 5 Impeller 1 6 Impeller Shaft 1 7 Sealing Ring 2 8 Shaft Cover 2 9 Suction Cup 4 10 Frame 1 11 Water Outlet 1 12 Pump Body 1 13 Motor 2 14 Grounded Termi...

Page 7: ...Page 7 For technical questions please call 1 888 866 5797 Item 63313 Assembly Diagram 20 2 1 9 14 6 5 3 12 18 4 13 7 8 11 15 19 16 17 10 7 7A 4A 3A 2A 1A 6A 5A 8A ...

Page 8: ...so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must accompany the merchandise If o...