Model

Code

Description

HD6-

⃞-

Green house open / close motor control only

Control type

F

ON / OFF Control

Input

N

TH-540N(103ET)

Control output

M

Relay

Power supply voltage

P4

100 - 240 V a.c.

Option

0

None sensor

2

2 m Incloud sensor

3

3 m Incloud sensor

5

5 m Incloud sensor

10

10 m Incloud sensor

15

15 m Incloud sensor

20

20 m Incloud sensor

Power supply voltage

100 - 240 V a.c. 50 - 60 Hz

Power consumption

2 VA max.

Input

TH-540N (103ET : -40.0 ~ 90.0 ℃, 2 m ~ 20 m)

Indicate accuracy

±1 % of FS +1 Digit

Control output (Relay)

OPEN OUT : 250 V a.c. 5 A ,   CLOSE OUT : 250 V a.c. 5 A

Control operation

ON/OFF control (Control by temperature and time)

Setting method

Digital method by FND and button

Ambient Temperature

0 ~ 50 ℃

Ambient Humidity

85 % R.H. max.

Weight

116 g

Please read the safety information carefully before the use, and use the product correctly.

The alerts declared in the manual are classified into 

DANGER

’, ‘

WARNING

’ and ‘

CAUTION

’ based on its importance

▍Safety information

   

DANGER

Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury

   

WARNING

Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury

   

CAUTION

Indicates a potentially hazardous situation which, if not avoided, may result in minor injury or properties damage

• The contents of this manual are subject to change without prior notice or notice.

• Check whether there is any damage or abnormality in the product during transportation.

• Use in a place where vibration or impact is not applied directly to the body.

• Use in a place free from water, oil, chemicals, steam, dust, salt, iron, etc.

• Avoid places where inductive obstacles are large and static electricity and magnetic noise are generated.

• The characters on the display may not be visible in outdoor sunlight or in a brightly lit indoor environment.

• For thermocouple input, use a prescribed compensation wire. 

  (In case of using general conductor, temperature error occurs.)

• In the case of RTD input, use one with a small lead wire resistance and no difference in resistance between three wires.

• Separate the input signal line and the output signal line from each other. If separation is not possible, 

   use a shielded line for the input signal line.

• Use a non-grounded sensor for thermocouples. 

  (If a ground sensor is used, the device may malfunction due to a short circuit.)

• If there is a lot of noise from the power, it is recommended to use an insulation transformer and a 

  noise filter. The noise filter must be attached to a grounded panel, etc., and the wiring between the noise 

  filter output side and the power supply terminal of the instrument must be short.

• When mounting this device to a panel, use a switch or circuit breaker approved by IEC60947-1 or IEC60947-3.

• The warranty organization for this device including accessories is 1 year under normal use.

• When the power is turned on, a preparation period for contact output is required. When used as a signal for an 

  external interlock circuit, etc., use a delay relay together.

• Before using the temperature controller, there may be a deviation from the measured value (PV) of the 

  temperature controller and the actual temperature, so please use it after correcting the temperature deviation.

• Failure or abnormality of this product may lead to a serious accident. In this case, 

  install an appropriate protection circuit outside.

• In case of use other than the method specified by the manufacturer, loss may occur.

• To prevent damage and breakdown of this device, supply the power voltage appropriate to the rating.

• There is a risk of electric shock, so use this product while it is installed on the panel while it is energized.

• The electric shock may occur in the input/output terminal so please never let your body and/or conductive 

  substance to be contacted by the input/output terminal.

Digital temperature controller

HD6

Thank you for purchasing Hanyoung Nux products. Please read the instruction 

manual carefully before using this product, and use the product correctly. 

Also, please keep this instruction manual where you can view it any time.  

MA0608KE210429

INSTRUCTION MANUAL

28, Gilpa-ro 71beon-gil,  Michuhol-gu, 

Incheon, Korea TEL : +82-32-876-4697 

http://www.hanyoungnux.com

HANYOUNGNUX CO.,LTD

DANGER

WARNING

CAUTION

▍Suffix code

▍Specification

[ Unit : ㎜ ]

Ø5.0

40

1,960

White

Black

• HD6 uses only this sensor. 

※ Caution : Extension of sensor length or modification will cause malfunction.

※ When sensor length is based on 2m

█ Sensor (NTC)

Name

Sensory type

Range(℃)

Accuracy

Remark

TH540N

Thermistor

-40.0 ~ 90.0

±1.5 ℃ Max ± 3.5 ℃ temperature deviation may be happen

(± 1.5 ℃ sensor deviation & ± 2 ℃ controller deviation)

▍Connection diagram

▍Custom Mode

█ Key operation function description

 : Keys for temperature setting and program setting

 : KEY for time setting

 ,  

 Increase/decrease key setting for setting value change 

Press 

 ,  

 for 3 seconds to save the changed data.

If there is no key input, the mode automatically exits after 10 seconds.

▍Dimension and panel cutout

▍Part name

Open operation

Close operation

Relay on

Relay off

Running time (sec/min)

Output indicate

Temperature setting 

and program setting

Time 

setting

decrease Increase