Hanyoung TPR-2N Instruction Manual Download Page 1

110 V AC, 220 V AC
50 Hz, 60 Hz (common)
25 A, 35 A
Protected by high-speed breaking fuse(external
attachment)
Resistive Load/ Inductive Load (use as a switch
conversion)

Input Current: 4 ~ 20 mA DC, Input Voltage: 1 ~5 V DC

Input Contact Point: ON-OFF, External V, R (10 

)

Phase control, Cycle control, ON/OFF control

SOFT START / DOWN
Above 95 % input voltage 
(when putting maximum of input voltage) 
Natural Cooling
Output display LED lighting
Above 100 

(at 500 V DC)

0 ~ 100 %
2000 V AC at 50/60 Hz for 1 minute
Noise by noise simulator(pulse width 1

:

2KV)

0 ~ 50 

(with no freezing)

30 ~ 85 % RH

-25 ~ 70 

Approx. 960 g

Aspect Dimension and Set-up Method

[Unit :   mm]

Before you use, read safety precautions carefully, and use this product properly.
The precautions described in this manual contain important contents related with
safety; therefore, please follow the instructions accordingly. The precautions are
composed of DANGER, WARNING and CAUTION.

To prevent electric shock while it is running, put to earth with the fixed screw of
the unit and do not touch the radiator panel since it is very hot. Do not touch or
contact the input/output terminals because they cause electric shock.

1. If this product is used with the machinery which may be caused human injury

or serious property damage then use it after surely installing the protection
equipment for two or three times.  

2. To prevent defection or malfunction of this product, supply proper power

voltage in accordance with the rating.

3. To prevent electric shock or malfunction of product, do not supply the power

until the wiring is completed.

4. Do not decompose, modify, revise or repair this product. This may be a cause

of malfunction, electric shock or fire.

5. Reassemble this product while the power is OFF. Otherwise, it may be a

cause of malfunction or electric shock

1. The place of operating this product affect to the its functions and life cycle so

that avoid to use it in the following circumstance.

A place of having high humidity and not circulating air
A place of piling dust or impurity or having high ambient temperature or high
vibration

2. The contents of this manual may be changed without prior notification.
3. Make sure that there is no damage or abnormality of the product during

delivery.

4. After turning OFF power sources of all instruments, please wire them.
5. The Thyristor Power Regulator shall be installed perpendicularly.
6. Install exhausting fan in internal and upside of the panel.
7. Tighten BOLT of the input and output wire enough.
8. Do not use this product at any place with corrosive (especially noxious gas or

ammonia) or flammable gas.

9. Do not use this product at any place with direct vibration or impact.

10. Do not use this product at any place with liquid, oil, medical substances, dust,

salt or iron contents. (Use at Pollution level 1 or 2)

11. Do not polish this product with substances such as alcohol or benzene.
12. Do not use this product at any place with a large inductive difficulty or

occurring static electricity or magnetic noise.

13. Do not use this product at any place with possible thermal accumulation due

to direct sunlight or heat radiation.

14. Install this product at place under 2,000m in altitude.
15. When the product gets wet, the inspection is essential because there is

danger of an electric leakage or fire.

16. Do not connect anything to the unused terminals.
17. After checking the polarity of terminal, connect wires at the correct position.
18. The warranty period for this product including parts is one year if this product

is properly used

How to Operate

When installing the unit, the input and output terminals shall be attached in the
direction of facing downward perpendicularly for the natural cooling.
Certainly, install high-speed breaking fuse between terminal R and power
source

Safety information

WARNING

CAUTION

DANGER

Power Supply

Operating Frequency

Rated Current 

Protection Circuit

Applied Load

Control Input

Control Method

(By switch Conversion)

Starting Method

Output Adjusting

Range 

Cooling Method

Indicator Function

Insulation Resistance

Output Range

Dielectric Strength

Line Noise

Operating Ambient

temperature

Operating Ambient

Humidity

Storage Ambient

Temperature

Net Weight

Ratings

HEAD OFFICE 

1381-3, Juan-Dong, Nam-Gu Incheon, Korea

TEL: (82-32)876-4697  FAX : (82-32)876-4696

MAIN PRODUCTS

- DIGITAL : Temperature Controller, Counter, Timer,Speedmeter, 

Tachometer, Panel Meter, Recorder

- SENSOR : Proximity Sensor/Photo Electric Sensor, 

Rotary Encoder, Optical Fiber Sensor,   
Pressure Sensor

- ANALOG : Timer, Temperature Controller

Thyristor Power Regulator

TPR-2N

We appreciate you for purchasing HanYoung NUX Co.,Ltd
product. Before using the product you have purchased,
check to make sure that it is exactly what you ordered. Then,
please use it following the instructions below.

INSTRUCTION MANUAL

Set-up Method

Model and Suffix code

Distinctive feature

Thyristor Power Regulator
Single Phase
110 V AC 50/60 Hz
220 V AC 50/60 Hz
25 A
35 A

Model Name

Suffix Code

Description

2N

110

220

TPR

Phase

Rated Current

Power Supply

25
35

Control Method: Phase control (factory default)

Since there is no moveable contact which is solid state relay control, life time is
semi-permanent
Due to the fast response time, you can control the temperature precisely.
Compared to the previous model, it becomes a simpler and better design.
Handling is easy, operating reliability is high and function has been improved.

Direct Set-up to the Panel

Set-up to the mounting track

Capacity (Current)

H

W

D

25 A, 35 A

Standard (Size)

100

92

131

MB01E050418

Reviews: