RT9

INSTRUCTION MANUAL

Thank you for the purchase of 

HANYOUNG

product.

Please read this manual carefully.

Recorder & Temperature Controller

هرﮐ

 

ﮓﻧﺎﯾﻧﺎھ

 

تﻻوﺻﺣﻣ

 

یرﺎﺻﺣﻧا

 

هدﻧﯾﺎﻣﻧ

 

ناوﯾﺳ

 

تﮐرﺷ

021-33989001

www.sivancarno.com

021-33989002

Summary of Contents for RT9

Page 1: ...ION MANUAL Thank you for the purchase of HANYOUNG product Please read this manual carefully Recorder Temperature Controller ﮐره ھﺎﻧﯾﺎﻧﮓ ﻣﺣﺻوﻻت اﻧﺣﺻﺎری ﻧﻣﺎﯾﻧده ﺳﯾوان ﺷرﮐت 021 33989001 www sivancarno com 021 33989002 ...

Page 2: ...PECIFICATION 5 DIMENSIONS PANEL CUTOUT 6 TERMINAL ARRANGEMENT 7 NAME FUNCTION 8 TABLE OF SETTING ITEMS 10 SETTING METHOD 20 GROUP SETTING 21 FUNCTION 4 6 6 7 11 11 12 13 15 16 23 2 ﮐره ھﺎﻧﯾﺎﻧﮓ ﻣﺣﺻوﻻت اﻧﺣﺻﺎری ﻧﻣﺎﯾﻧده ﺳﯾوان ﺷرﮐت 021 33989001 www sivancarno com 021 33989002 ...

Page 3: ... RS485 Free scale PID Auto tuning Record and Temperature control Universal Input Output Small sized Recorder Temperature controller 0 3 class high accuracy 3 Features Model RT9 ﮐره ھﺎﻧﯾﺎﻧﮓ ﻣﺣﺻوﻻت اﻧﺣﺻﺎری ﻧﻣﺎﯾﻧده ﺳﯾوان ﺷرﮐت 021 33989001 www sivancarno com 021 33989002 ...

Page 4: ...al shock or malfunction 5 Caution on maintenance Turn OFF the power before mounting or removing the instrument To ensure continuous and safe operation of the instrument periodical maintenance is recommended Some parts are limited in life The warranty period is 1 year only if using in the correct way CAUTION 1 Caution on handling Do not install the instrument under any of the following condltions T...

Page 5: ...ld be shorten It is effective to use a twisted cable for power supply against noise The heater power supply and the instrument power supply should be connected using the same power suppy when a heater break alarm Time for preparation of contact output is required at power ON When the output signal is used for an extenal interlock circuit connect a delay relay 4 For load circuit connection Use an e...

Page 6: ...rd type low PV type Communication RS485 20 types of alarm Sampling cycle 250ms 0 3 of FS high accuracy And there are Zoom function Graphic or Text printing selectable function List printing function Feed function Free scale function RT9 is the smallest Recorder with controller Recorder Temperature Controller Control Output Output code RT9 96 96 mm Recorder Recorder Temperature Controller Others No...

Page 7: ...nge of measurement Scaling available CONTROL OUTPUT Relay contact output SSR drive voltage output Current output 4 20 mA DC Contact capacity 240 V AC 3 A 30 V DC 3 A resistive load Contact 1 C Output operation P I D control ON OFF Proportional cycle 1 1 000 sec Output limit 0 0 100 0 range higher limit OH or lower limit OL selectable valid when AT ON OFF hysteresis 0 100 Full scale Time resolution...

Page 8: ...rameter Ramp function Set point 2 Points Multi alarm High Low process alarm High Low deviation alarm Hold function of alarm Heater break alarm H B A Setting range Process alarm 0 100 of instrument range Deviation alarm 100 100 of instrument range Measuring point 1 Response time According to chart speed Record type Thermal line 203 dpi 8 0 dots mm 384 dots 1 line Record speed 24 mm h 900 mm h Paper...

Page 9: ...nization Communication sequence Communication distance Communication speed Start bit Data bit Parity bit Stop bit Communication protocol Response time EIA RS485 Max 31 1 99 setting available 2 wire half duplex or 4 wire half duplex Start stop synchronous mode None 1 2 Km max 600 1200 2400 4800 9600 BPS Speed is changeable by parameter 1 BIT 7 or 8 BIT None even numbers odd numbers 1 or 2 BIT PC LI...

Page 10: ...99 9 300 1180 1 2 3 4 5 6 7 8 9 10 11 12 13 20 21 30 31 32 33 30 2 2 2 2 2 2 1 2 2 3 3 200 1370 199 9 999 9 199 9 999 9 199 9 999 9 199 9 400 0 0 1700 0 1800 0 1700 199 9 900 0 200 1300 199 9 400 0 0 2300 0 1390 199 9 500 0 199 9 640 0 F S is maxium value minimum value of each RANGE Digit is minimum value of display 1 0 400 10 of F S 1 digit 2 0 and below 1 0 of F S 1 digit 3 150 0 150 0 range 1 0...

Page 11: ...rmina no Termocouple R T D A B Direct Voltage Alarm1 Terminal no Alarm2 Terminal no Sending data Receiving data Earth for signal Control Output POWER Input AL1 AL2 Communication RS 485 Unit mm RT9 96 96 mm Terminal structure ﮐره ھﺎﻧﯾﺎﻧﮓ ﻣﺣﺻوﻻت اﻧﺣﺻﺎری ﻧﻣﺎﯾﻧده ﺳﯾوان ﺷرﮐت 021 33989001 www sivancarno com 021 33989002 ...

Page 12: ... when the auto tuning operates Lights when the control output is ON Model name Manufacturer Used to change mode Used to increase set value Used to decrease set value Used to select digit for changing Name P END RUN AL1 AL2 Set value SV Process value PV AT OUT RT9 HANYOUNG Key NAME FUNCTION 12 7 Front Displays Control keys ﮐره ھﺎﻧﯾﺎﻧﮓ ﻣﺣﺻوﻻت اﻧﺣﺻﺎری ﻧﻣﺎﯾﻧده ﺳﯾوان ﺷرﮐت 021 33989001 www sivancarno co...

Page 13: ...a number Output volume display Recorder only RT9 0 Control group Alarm group Optional Communication group Optional Input group Time setting group will be displayed Parameter structure Group Control Group Autotuning Group P I D ﮐره ھﺎﻧﯾﺎﻧﮓ ﻣﺣﺻوﻻت اﻧﺣﺻﺎری ﻧﻣﺎﯾﻧده ﺳﯾوان ﺷرﮐت 021 33989001 www sivancarno com 021 33989002 ...

Page 14: ...14 Group Alarm Group Communication Group Output Group Input Group Time setting ﮐره ھﺎﻧﯾﺎﻧﮓ ﻣﺣﺻوﻻت اﻧﺣﺻﺎری ﻧﻣﺎﯾﻧده ﺳﯾوان ﺷرﮐت 021 33989001 www sivancarno com 021 33989002 ...

Page 15: ...ol Group Alarm Group Communication Group Input Group Time setting Recorder Model RT9 0 Recorder Controller Model RT9 1 Parameter shift Power ON How to operate RECORDER RUN Press buttons simultaneously RUN lamp will be ON Stop Press buttons simultaneously RUN lamp will be OFF Graphic or Text printing selection In condition of printing press button for 3 sec Graphic Text Graphic List printing In con...

Page 16: ...of transmission Zoom Set a control mode OFF ON OFF ON OFF EUS 0 100 OFF EUS 0 100 HOUR MIN 24 900 mm hour OFF ON Always Except ON OFF Always Always Always Always Always Always OFF OFF OFF OFF HOUR 60 OFF 16 GROUP SETTING 10 Initial Condition Description Display Name Signal Display level setting Divide display levels into 3 stages 1 3 3 Always Control group setting Display level setting ﮐره ھﺎﻧﯾﺎﻧﮓ...

Page 17: ...nitial Condition Description Name Signal Auto tuning group Auto tuning type Auto tuning start Indicates Auto turing OFF 1 3 RT9 1 ABS ABS P I D group Anti Reset Wind up P I D group selection n Proportional band P n Integral time I n Derivative time D n Manual reset n Zone position RT9 1 Except ON OFF Always P I D group P I D group P I D group Integral time OFF ZONE ON Auto 0 5 0 240 sec 60 sec 50 ...

Page 18: ...onal Time Zone3 Set point of Zone 2 2 RP Set point of Zone 1 1 RP Maximum Range Eu 100 Minimum Eu 0 Zone2 Zone1 There are 2 alarm outputs available per controller In Alarm Group setting are made for mode dead band and value of each alarm Refer to the next page for the 20 different types of alarm functions Initial value Condition Description Name Signal 1 2 EUS 0 5 EU 100 0 EU 0 0 Optional Always A...

Page 19: ...ith hold function High deviation with hold function Low deviation with hold function High deviation with hold function inverted Low deviation with hold function inverted High Low deviation with hold function High Low band with hold function High absolute value with hold function inverted Low absolute value with hold function inverted Function ALARM TYPE AND CODE Alarm type Hysteresis Notice Displa...

Page 20: ...ration Cycle time Hysteresis Output volume when input disconnection Output Out Maximum value of output Minimum value of output Model RT9 1 Always Always Relay SSR ON OFF Control Always Except ON OFF Except ON OFF 3 REV 30 sec 0 0 0 100 0 0 0 Initial value Condition Description Name Signal Output type and mode selection Refor to type of control output REV Reverse DIR Direct action 1 1000 sec EUS 0 ...

Page 21: ... voltage input 30 31 32 33 Selection NO 1 1370 200 1 100 0 0 0 OFF EUS 0 0 UP Initial value Condition Description Name Signal Input group Input signal selection High limit Low limit Decimal point on voltage input Maximum on scale on voltage input Minimum on scale on voltage input PV filter PV bias Burn out Input type and mode selection Refer to input signal and range Refer to input signal and rang...

Page 22: ...cts of noise the filter helps suppress the unstable status Range OFF or 1 120 sec initial value OFF PV bias Use this function to adjust PV value in cases where it is necessary for PV value to agree with another recorder or indicator or when the sensor cannot be mounted in correct location Range 100 0 100 0 of SPAN lnitial value 0 0 Setting a value using or key and press key to finish Initial value...

Page 23: ...computes and sets the optimum Proportional band P Integral time I and Derivative time D When Auto tuning the controller performs ON OFF control and determine proper P I and D Limit cycle type RT9 1 series have two types of Auto tuning as below Standard type auto tuning This type is based on set point value SV Low PV type auto tuning This type is based on the value 10 lower than the set point value...

Page 24: ...gh and low limit as operating range Output limit is 5 105 of output OUTPUT LIMIT 20 mA Output signal 12 mA 4 mA OL H Output limit OL L setting range 105 50 5 When A D error or input disconnection occur in auto mode PID output is cut and than Pre set output is operated PO Output Emergency output Hold function Hold function None Picture 1 HOLD FUNCTION Without hold function Low limit alarm will be O...

Page 25: ...MEMO ﮐره ھﺎﻧﯾﺎﻧﮓ ﻣﺣﺻوﻻت اﻧﺣﺻﺎری ﻧﻣﺎﯾﻧده ﺳﯾوان ﺷرﮐت 021 33989001 www sivancarno com 021 33989002 ...