Hanyoung PL-D2B Instruction Manual Download Page 1

3

4

•If you do not follow instruction in this manual, injury or damage of property may occur. 

•Please do not use outdoor
   (It may cause of shorten the life of the product or electric shock). 
•Do not use flammable, explosive gas environments. 
   Please do not use this product at any place where have over specification of 
   vibration and shock.
•Please use a dry cloth to wipe off dusts and do not use thinner or solvent.
•Power switch and fuse are not attached to this product.  Please install them separately 
   on the outside.  

Warning

•When cleaning the lens and the case, please use a dry cloth and gently wipe the surface.  
   Must not use solvents such as thinner or alcohol. 
•The sensor wire should be separate from high voltage line or power line. Having the same 
   pipe for wiring can be cause of malfunction. 
•This product has (IP 65) water proof structure but do now use permanent underwater place.
•When extending the cable, please use thick wire (at least thickness ㎟) and at this moment, 
   please watch out for the voltage-drop.
•When using the sensor under the light such as fluorescent lighting or mercury lamp with 
   high frequency, please block it with a light rap and avoid the lens from facing the light directly.
•When 2 units of through beam type of photo sensor are used, it can be cause 
   of malfunction due to interference. Please make enough space and please install the 
   receiver and emitter positions are crossed. 
•In case of use Inductive load (relay, coil), the instantaneous load increases 2 times and it 
   may break TR. So, please set maximum load at half.
•Output has over current protection circuit so it blocks output when output is higher than 
   rated load current. So please set 70% from the maximum load.
•A lot of dusts pollute lens and it may cause of malfunction so please avoid using this 
   product dust area. 
•Information in the manual may changed without prior notification. 
•When using the switching power supply as the power source, earth the frame ground (F.G) 
   terminal and be sure to connect the noise eliminating condenser between 0 V and F.G.

Caution

Frame

Power 

Supply

(SMPS)

C(0.01㎌-0.1㎌/500 V)

- Noise eliminating 

condenser-

Photo 

Sensor

※ Not following safety issues which stated above may cause product to break down so users 
   must follow them.

•Distance Setting type and BGS (Background suppression) function.
•Stable detection is possible without influence color & quality 
   of detection object. 
•Long detection distance (2 m) and can be applied in various fields.
•Built in the reverse connection of power protecting circuit and built 
   in the output break protecting circuit
•IP65 Protective structure(IEC)

Characteristic

Specification

Model

PL - D2B

Sensing method

Distance-settable

Sensing distance

0.2 ~ 2 m

Sensing object

200 X 200 ㎜ White paper with no gloss

Power supply voltage

12 - 24 V d.c ±10 %

Current consumption

30 ㎃ max.

Control output

NPN / PNP open collector asynchronously,

Load current : 150 ㎃ d.c max. (Resistive load) 

NPN residual voltage : 1 V d.c max., PNP residual voltage : 2 V d.c max   

Operation mode

Light ON / Dark ON ※ Selectable by the mode V/R

Response time

2 ㎳ max.

Hysteresis

Less than 10 % of the sensing distance

Light source

(Wave length)

Infrared lightening LED (880 nm)

Receiving part

2 photo diodes

Display

Control out display : Red LED, Stability display: Green LED

Distance setting

Near/Far : Optical distance adjusting volume 5 cycles.

Protective circuit

Power reverse connection protecting circuit and output break protecting circuit 

Ambient illumination

Sunlight : 11,000 lx max., Incandescent lamp : 3,000 lx max.

Ambient temperature

Operation : -20 ~ 60 ℃, Storage : -25 ~ 70 ℃ (Without freezing)

Ambient humidity

35 ~ 85 % RH (Without condensation)

Protective structure

IP 65

Insulation resistance

20 ㏁ min.(500 V d.c Mega)

Dielectric strength   

1000 V a.c (50/60 Hz for 1 min)

Vibration resistance 10 - 55 Hz, Double amplitude : 1.5 mm for 2 hours each in X. Y and Z directions.

Shock resistance

500 ㎨ 3 times each in X. Y and Z directions.

Connection method Cable output type, Number of wires : 4P, Thickness :Ø 4 mm, Length 2 m

Material

Case : PC, Lens : PC

Accessory

Bracket, Adjustable driver, bolt, Nut. 

Connection diagram

MK1801KE130109

    Photo sensor

 

PL-D2B

 

       Thank you for purchasing HANYOUNG product.

       Please check whether the product is the exactly same as you ordered. 

       Before using the product, please read this instruction manual carefully.

       Please keep this manual where you can view at any time

 INSTRUCTION MANUAL

1381-3, Juan-Dong, Nam-Gu Incheon, Korea.  
TEL:(82-32)876-4697
FAX:(82-32)876-4696
http://www.hynux.net

HANYOUNGNUX CO.,LTD

HEAD OFFICE

INDONESIA

FACTORY

JL.CEMPAKA BLOK F 16 NO.02 DELTA SILICON II 
INDUSTRIAL PARK
LIPPO CIKARANG CICAU, CIKARANG PUSAT BEKASI 
17550 INDONESIA
TEL : 62-21-8911-8120~4  FAX : 62-21-8911-8126 

PT. HANYOUNG ELECTRONIC INDONESIA

Safety information

Before using the product, please read the safety information thoroughly and use it properly.Alerts 
declared in the manual are classified to Danger, Warning and Caution by their criticality

DANGER

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury

WARNING

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury

CAUTION

CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury

Dimension

66.5

23.7

65.0

BR

AKET-A ASS'Y

56.7

18.0

18.0

11.

2

15.9

BR

AKET-B ASS'Y

22.6

54.5

Ø4.5

Ø4.5

22.

6

54.5

30.0

22.0

12.

5

9.7

15˚

56.7

18.0

15.9

60.7

54.1

5.5

23.7

12.0

22.5

30.0

16.6

Ø4.5

Ø4.

5

15˚

[Unit : mm]