4.4.3  Side panel                                                                                               

 

Figure 4.8 Right panel 

1. 

Multimeter interface 

V/

Ω

/C

COM

mA

A. The specific connection mode can be seen on the screen 

after selecting the gear to be tested. 

2. 

Power switch 

When the machine is off, press the power switch to start the machine. Press the 

power switch again to shut down the machine. 

 

Figure 4.9 Left panel 

1. 

USB interface 

Summary of Contents for Tablet1000 Series

Page 1: ...Tablet1000 series Tablet oscilloscope User Manual 2022 05...

Page 2: ...ve version If you use documents or products of Qingdao Hantek Electronics Co LTD and need products patents or works of third parties to cooperate with them you shall be responsible for obtaining the c...

Page 3: ...rity issues 1 1 2 Security terms and signs 2 1 3 Measurement category 2 1 4 Working conditions 3 1 5 Maintenance and cleaning 4 1 6 Environmental Considerations 5 2 Product features 6 3 Document overv...

Page 4: ...ear Panel 16 4 4 3 Side panel 17 4 4 4 Main interface 19 4 5 Touch screen gesture 20 4 5 1 Touching 20 4 5 2 Kneading 20 4 5 3 Dragging 21 4 6 Setting parameters 21 5 Set the horizontal system 24 5 1...

Page 5: ...20M bandwidth limit 28 6 6 Waveform inversion 29 6 7 Probe 29 6 8 Amplitude unit 29 7 Mathematical operations 31 7 1 Algebraic operation 31 7 2 FFT operation 32 8 Reference channel 35 9 Trigger oscill...

Page 6: ...rement 45 10 2 Measurement parameters 45 10 2 1 Time parameters 46 10 2 2 Count parameters 47 10 2 3 Delay and phase parameters 48 10 2 4 Voltage parameters 49 10 3 Cursor measurement 50 10 3 1 Vertic...

Page 7: ...ess 59 12 5 Waveform brightness 59 13 Save 60 14 Calibration 61 15 Shortcuts 62 15 1 Auto setting 62 15 2 Default setting 63 16 Multimeter 65 16 1 Measurement 66 17 Signal source 68 17 1 Set the outpu...

Page 8: ...ual Copyright Qingdao Hantek Electronics Co LTD VI 18 File browse 73 19 Settings 75 20 Gallery 78 21 Remote control 79 22 Fault handling 81 23 Appendix 82 23 1 Appendix A Accessories 82 23 2 Appendix...

Page 9: ...4 7 Rear view 16 Figure 4 8 Right panel 17 Figure 4 9 Left panel 17 Figure 4 10 Upper panel 18 Figure 4 11 Main interface 19 Figure 4 12 Touching gesture 20 Figure 4 13 Kneading gesture 21 Figure 4 14...

Page 10: ...pe trigger menu 43 Figure 9 6 Timeout trigger menu 44 Figure 10 1 Measurement parameters 45 Figure 10 2 Vertical cursor 50 Figure 10 3 Horizontal cursor 51 Figure 11 1 Phase difference schematic diagr...

Page 11: ...ngdao Hantek Electronics Co LTD Tablet1000 User manual IX Tables Table 3 1 Model 10 Table 15 1 Automatic setting 63 Table 15 2 Automatic setting of sine waves 63 Table 15 3 Default setting 64 Table 19...

Page 12: ......

Page 13: ...t Ground the product To avoid electric shocks the product is grounded through a grounding conductor of the power cable The grounding conductor must be connected to the ground before connecting the inp...

Page 14: ...ments may not provide adequate protection for broadcast services in residential environments 1 2 Security terms and signs Security terms in this manual Warning Indicates that the operation may not cau...

Page 15: ...ar equipment Class III refers to measurements taken on construction equipment For example measurements made on switchboards circuit breakers circuits including cables busbars junction boxes switches s...

Page 16: ...pply The degree of pollution 2 class Definition of pollution level Pollution degree 1 no pollution or only dry non conductive pollution This pollution level has no impact For example clean room or air...

Page 17: ...ing reagent Warning Before powering on the device again ensure that the device is dry enough to avoid electrical short circuit or personal injury caused by moisture 1 6 Environmental Considerations Th...

Page 18: ...at plate oscilloscope Basic trigger functions edge pulse width video slope timeout Up to 42 waveform parameters are automatically measured Various mathematical operations addition subtraction multipli...

Page 19: ...n which can monitor and record voltage current resistance and other data changes for a long time and generate trend charts Standard 9V2A 5V3A 12v1 5A charger USB interface input can share a set of cha...

Page 20: ...virtual keys and main interface icons For example HOME is for OSC is for 2 Menu Use menu text bold color to represent a label or a menu option For example Basic Settings means to click the Basic Setti...

Page 21: ...GSa S Yes TO1252C 2 250MHz 1GSa S Yes TO1152D 2 150MHz 1GSa S 25MHz Yes TO1202D 2 200MHz 1GSa S 25MHz Yes TO1252D 2 250MHz 1GSa S 25MHz Yes TO1154 4 150MHz 1GSa S TO1204 4 200MHz 1GSa S TO1254 4 250MH...

Page 22: ...ument overview EN Tablet1000 User manual Copyright Qingdao Hantek Electronics Co LTD 10 Model Channel Bandwidth Sampling rate Signal source Multimeter TO1254AUTO 4 250MHz 1GSa S 25MHz Yes Table 3 1 Mo...

Page 23: ...sly damaged please keep them until the whole machine and accessories pass the electrical and mechanical testing Check the accessories The details of the accessories are provided in Appendix A Accessor...

Page 24: ...Tap the screen to cancel the popup box Shutdown after 20 seconds and shutdown after 10 seconds will appear subsequently To avoid automatic shutdown due to insufficient power supply please charge in ti...

Page 25: ...Click HOME to enter the main interface and click Settings Language to select the language The default language is English 4 3 4 Functional check Click OSC or tap OSC in the main interface to enter th...

Page 26: ...urement errors To adjust the probe compensation please follow the following steps 1 Connect one end of the probe to the CH1 channel and the other end to the AFG channel 2 Enter the oscilloscope interf...

Page 27: ...Step 3 The adjustment method is shown in the following figure Figure 4 5 Adjust the probe4 4 4 Product introduction This section introduces the front rear side panel and the main interface of the osc...

Page 28: ...eter is not supported AFG Shortcut key of the signal source Tap to enter the signal source interface If the machine does not support the signal source function a message will pop up indicating that th...

Page 29: ...ight panel 1 Multimeter interface V C COM mA A The specific connection mode can be seen on the screen after selecting the gear to be tested 2 Power switch When the machine is off press the power switc...

Page 30: ...omputer and the user can connect the upper computer software or send SCPI instructions This interface is also a charging port which can charge the machine with the power adapter and USB cable delivere...

Page 31: ...page 4 File browsing Tap to enter the file browsing page Pictures saved by PRINT and the content saved in the oscilloscope interface will be saved in the file browsing 5 Settings Tap to enter the sett...

Page 32: ...ny other characteristics providing better operation experience 4 5 1 Touching Tap a menu or function on the screen with your finger as shown in the following picture The functions that touching can ac...

Page 33: ...s shown in the following figure The functions that can be achieved by dragging are Drag the waveform to change the displacement and offset of the waveform Drag the cursor to change the cursor position...

Page 34: ...ercase letters All input will be displayed in the input box 3 Type lowercase letters Refer to the previous step Lowercase letters are default 4 Enter a number or symbol The upper part of the virtual k...

Page 35: ...s complete You can also perform the following operations on the numeric keypad Delete entered parameter value Set the parameters to the maximum or minimum sometimes especially referring to the maximum...

Page 36: ...orizontal displacement is changed the waveform trigger points and displayed waveforms of all channels move left and right The horizontal displacement at the top of the screen changes in real time as s...

Page 37: ...e changes Touch to adjust horizontal time base Kneading gesture is used to adjust horizontal time base Please refer to Kneading chapter for detail Set the horizontal time scale to horizontally amplify...

Page 38: ...This chapter describes how to set CH1 Please read this section carefully to understand the settings functions and operations of the vertical system Figure 6 1 Channel vertical menu 6 1 Open or close...

Page 39: ...ent or fine adjustment for the vertical gear By default it is rough adjustment If fine adjustment is checked fine adjustment will be applied Fine adjustment After selecting fine adjustment the vertica...

Page 40: ...ode is set the current coupling mode is displayed in the channel label as shown in the figure below 6 5 20M bandwidth limit This oscilloscope supports bandwidth limit Setting bandwidth limit can reduc...

Page 41: ...Waveform inversion 6 7 Probe Open Vertical channel Probe The oscilloscope allows the user to set the probe attenuation ratio manually The user must set the probe ratio correctly to obtain accurate me...

Page 42: ...Set the vertical system EN Tablet1000 User manual Copyright Qingdao Hantek Electronics Co LTD 30 When the amplitude unit is changed the unit of related functions are also changed...

Page 43: ...and display the results Subtraction Subtracts the signals from data sources 1 and 2 point by point and displays the results Multiplication Multiply the signals from data sources 1 and 2 point by point...

Page 44: ...al axis shows frequency Data source Select the data source CH1 to CH4 to perform the calculation Vertical units Select the unit of the vertical scale VRms or dB Window Applied to FFT Window functions...

Page 45: ...the vertical unit and click the arrow to select dB or VRms 5 Select the FFT function and click the arrow to select different window functions 6 Set the frequency of frequency domain waveform correspon...

Page 46: ...e mode Use cursor to measure FFT waveform To perform cursor measurement tap the vertical or horizontal cursor at the bottom of the interface Use the AX and BX cursors to measure the frequency and the...

Page 47: ...It is also necessary to plug in the USB disk to call the reference waveform in the USB disk Reference waveform calling and closing This series of oscilloscopes support calling reference waveform On t...

Page 48: ...rm movement and time base adjustment Horizontal and vertical movement and scaling of the reference waveform are independent of each channel The method of adjusting the horizontal or vertical position...

Page 49: ...xternal trigger channel for edge triggers only Click the trigger icon at the bottom of the screen to enter the Trigger menu 9 1 Trigger level Trigger level Trigger level is the signal voltage correspo...

Page 50: ...d trigger Under normal and single trigger mode click the forced trigger button in the trigger menu to force a trigger signal When not getting enough knowledge of the feature of a signal set in automat...

Page 51: ...sually slightly less than one repeat of the waveform Setting the hold off time to this time generates a unique trigger point for the repeated waveform Changing the time base does not affect the trigge...

Page 52: ...trigger triggers on positive or negative pulses of specified width Trigger source polarity positive pulse width negative pulse width limiting conditions and pulse width can be set in this menu 1 Clic...

Page 53: ...Triggered when the input signal positive pulse or negative pulse width is not equal to the set pulse width equal to time value Triggered when the input signal positive pulse or negative pulse width i...

Page 54: ...hold off 6 Click Standard and select the desired video standard This series of oscilloscopes support video standards NTSC PAL HDTV720p HDTV1080p HDTV1080i 7 Click Sync select the required field or li...

Page 55: ...e or negative slope time of the input signal is less than the set time value greater than time value Triggered when the positive or negative slope time of input signal is greater than the set time val...

Page 56: ...urce 4 Click Mode and select trigger mode automatic normal single 5 Click Holdoff to adjust the trigger hod off 6 Click Polarity to select positive or negative polarity trigger Positive polarity Start...

Page 57: ...e measurements If it is calculated that there are six main vertical scale divisions between the maximum and minimum values of the waveform and the scaling coefficient is known to be 50mV division the...

Page 58: ...lling time The time that the signal amplitude decreases from the upper limit to the lower limit of the threshold 5 Positive pulse width The time difference between the threshold midpoint of the rising...

Page 59: ...falling from above the upper threshold to below the lower threshold 3 Number of rising edges The number of rising edges rising from below the lower threshold to above the upper threshold 4 Number of f...

Page 60: ...e first rising edge of data source A and the last rising edge of data source B 6 LRF Last Delay Rise Fall A B indicates the time between the first rising edge of data source A and the last falling edg...

Page 61: ...sult of the ith point and n is the number of points measured 10 Vrms root mean square value over the entire waveform or gated region 11 Per Vrms the root mean square value within a period Where xi is...

Page 62: ...cursors vertical and horizontal Horizontal cursor The amplitude cursor displayed as a horizontal dashed line is used to measure parameters in the vertical direction Vertical cursor The time cursor di...

Page 63: ...see Dragging section 10 3 2 Horizontal Cursor The horizontal cursor displays a horizontal line on the screen that measure the horizontal parameters of the waveform The operation steps are as follows...

Page 64: ...Tablet1000 User manual Copyright Qingdao Hantek Electronics Co LTD 52 Horizontal cursor movement Use the touch screen function to adjust the cursor position by dragging gestures For details see Draggi...

Page 65: ...detection acquisition mode should be applied Average Under this mode oscilloscope takes a number of waveform and then takes the average and displays the average waveform which can be used to reduce r...

Page 66: ...great relationship with the time base which can be roughly calculated as the number of grids on the left of the trigger position the time base gear If you want to reduce the wait time you can move the...

Page 67: ...XY mode To do this stop the acquisition and change the display mode to XY Scroll mode Waveform refresh display from right to left The range of the horizontal time base is 100ms to 100s Figure 11 2 Scr...

Page 68: ...the maximum storage depth is 8M In double channel mode the maximum storage depth is 4M In triple or quadruple channel mode the maximum storage depth is 2M Tip Under sAutomatic mode the oscilloscope a...

Page 69: ...ng rate is 3 to 5 times the system bandwidth Step interpolation Insert the value of the previous sample point between adjacent sample points This algorithm is the same as the normal sampling of the os...

Page 70: ...y the sample points are connected by lines This mode provides the most realistic waveform in most cases and makes it easy to view the steep edges of the waveform e g square wave 12 2 Persistence Selec...

Page 71: ...d dotted line Solid line The background grid is solid line None No background grid Dots and lines The background grid is a dot 12 4 Grid brightness Adjust grid brightness by sliding the slider left an...

Page 72: ...al memory of the machine in the format lwf Binary files support call out 3 Settings Save the oscilloscope settings to the internal or external memory of the machine in the format pho Settings files su...

Page 73: ...30 minutes before self calibration Follow the on screen prompts To compensate for the signal path disconnect any probes or cables connected to the input connector Under the oscilloscope menu click Au...

Page 74: ...nd adjust the control mode to accurately display the waveform of the input signal Function Settings Acquisition mode Sampling or peak detection Cursor OFF Display mode YT Display type FFT spectrum is...

Page 75: ...the signal resembles a sine wave the oscilloscope will display the following options Waveform options Detailed instructions Multiple cycles Display multiple cycles with appropriate vertical and horizo...

Page 76: ...edge Type Edge Data source CH1 Slope Rising edge Method Automatic Level 0 00 v Vertical system all channels Bandwidth limit Unlimited Voltage grid Rough adjustment Probe attenuation 1X Phase inversion...

Page 77: ...Multimeter Value range The range of current measurement gear maximum and minimum Numerical display Real time display of the current measured value Measurement gear DC voltage V DC voltage mV resistan...

Page 78: ...mA select DC milliampere mA and AC milliampere mA insert the black probe into the COM banana jack input terminal and the red probe into the mA banana jack input terminal Connect the red and black prob...

Page 79: ...eading of the positive conduction voltage for the diode The unit is in V 6 On off measurement Click DMM on the main interface to enter the multimeter interface Select sound the buzzer rings Insert the...

Page 80: ...to call out the numeric keypad to set the value 4 Click Amplitude to set the amplitude Click it again to set the high level the offset is automatically switched to the low level Click the number to c...

Page 81: ...of frequency modulation that is the offset between the modulated waveform frequency and the original carrier frequency The range is 0 1Hz 1KHZ carrier frequency Carrier wave is the modulated wave and...

Page 82: ...ort the CSV file to the arbitrary waveform editor interface Export to a CSV file Save waveform data to a CSV file Import from an ARB File Import ARB file into the arbitrary waveform editor interface E...

Page 83: ...sets the duty cycle when selecting a square triangle or diagonal using the standard waveform shape button Duty cycle is defined as the time the signal is above zero volt divided by the total period t...

Page 84: ...orm file or draw an arbitrary waveform Click Menu and choose Export to ARB file save the file to your computer or elsewhere 4 Copy the ARB files saved to your computer to the USB storage device The US...

Page 85: ...e opened in the Gallery you can choose the last or next one or delete Click Return to return to the gallery interface Reference The reference waveform file can directly open the reference channel in t...

Page 86: ...is selected the first file will be deleted Rename The renaming rule is a combination of letters and digits Select the file to rename Click Rename The keyboard will pop up Set the name Click Enter to...

Page 87: ...ess Adjust screen brightness Upgrade Insert a USB flash drive with only a upgrade file Click the Upgrade soft key Automatic lock Automatic lock time and automatic shutdown time USB sharing Connect the...

Page 88: ...ll be updated The self calibration should be performed after upgrade After the upgrade is successful the saved files and pictures will be cleared Note The USB storage device can contain only the upgra...

Page 89: ...Qingdao Hantek Electronics Co LTD Tablet1000 User manual 77 3 The computer pops up a removable disk and opens it to read files stored in the machine mini_pic image ref csv setup wave mask 4 Click ON O...

Page 90: ...ary Save select the save type as picture and click Save Click the picture in the gallery you can select the Last Return to gallery Delete Next tabs for operation A maximum of 16 images can be saved in...

Page 91: ...to start the installation The installation process may take several minutes After the installation you can view the I O software running in the lower right corner of the screen Connect the Type A end...

Page 92: ...manual Copyright Qingdao Hantek Electronics Co LTD 80 Double click to open the upper computer software If you see the connection information in the lower left corner of the interface it indicates the...

Page 93: ...it is a DC signal and the amplitude is high adjust the amplitude gear to a higher value Press the automatic measurement button to automatically detect the signal first If still no waveform is displaye...

Page 94: ...Hz 2 channel oscilloscope multimeter signal source TO1112D 1GSa S 150MHz 2 channel oscilloscope TO1152 1G Sa S 200MHz 2 channel oscilloscope TO1202 1G Sa S 250MHz 2 channel oscilloscope TO1252 1G Sa S...

Page 95: ...Sa S 250MHz 4 channel oscilloscope TO1254 1G Sa S 150MHz 4 channel oscilloscope multimeter TO1154C 1G Sa S 200MHz 4 channel oscilloscope multimeter TO1204C 1G Sa S 250MHz 4 channel oscilloscope multi...

Page 96: ...summary Qingdao Hantek Electronics Co LTD hereinafter referred to as Hantek undertakes that the host and accessories of its production shall be free from any material and process defects during the wa...

Page 97: ...Appendix EN Copyright Qingdao Hantek Electronics Co LTD Tablet1000 User manual 85 liable for indirect special or consequential damages...

Page 98: ...0 Baoyuan Road High tech Zone Qingdao Shandong China 266114 Switchboard 400 036 7077 Email service hantek com Tel 0086 532 55678770 55678772 55678773 Zip code 266114 Website www hantek com Qingdao Han...

Reviews: