background image

 

 
 

 

 

User’s Guide 

 
 

LA5034 

Operation Manual

   

 

 

 

 

 

                                                                                     

Summary of Contents for LA5034

Page 1: ...User s Guide LA5034 Operation Manual...

Page 2: ...2 Menu 11 File 12 View 13 Setup 14 Analyzer 15 Help 16 Chapter 3 Advanced 17 Clock Panel 18 Bus Panel 19 Waveform Panel 22 Measurement Panel 24 Export Data 25 Chapter 4 Trigger 26 Base Trigger Setup 2...

Page 3: ...mport or export of products before the end be sure to correct grounding for this product Properly connected probe Probe the ground with the same potential Do not connect high voltage ground See all th...

Page 4: ...ce The LA5034 has the feature of delayed ability to capture the required observation points around the waveform in a variety of digital information capture function The LA5034 has adequate memory capa...

Page 5: ...LA5034 Chapter 1 Getting started This chapter focuses on the following topics System Requirements Installing hardware Installing software Understanding of the user interface LA5034 User s Manual 1...

Page 6: ...Memory 128MB Graphic Card Microsoft DirectX supported Screen resolution 1024x768 Color depth 16bit z Recommended System Requirements Operating System Windows 2000 XP Vista Win 7 Memory 256MB Graphic C...

Page 7: ...ng Hardware 1 Connect the A Type Plug of USB cable to your PC s USB port 2 Connect the B Type Plug of USB cable to LA5034 s USB port 3 New hardware is found 4 New hardware search wizard starts LA5034...

Page 8: ...LA5034 5 New hardware search wizard starts to search 6 New hardware wizard installs software LA5034 User s Manual 4...

Page 9: ...or you may lose data and or your ability to communicate with the LA5034 If the LED is illuminated but the turns off the computer has lost communication with the LA5034 To restore communication discon...

Page 10: ...t the installation CD into the CD ROM drive 2 The installation should start up automatically Otherwise in Windows Explorer switch to the CD ROM drive and run Setup exe 3 The LA5034 Installation is sta...

Page 11: ...LA5034 4 Choose a destination directory Click Next to continue 5 Check the setup information Click Next to start copying of files LA5034 User s Manual 7...

Page 12: ...LA5034 6 This Status dialog is displayed during copying of files 7 Updating Your System Configuration LA5034 User s Manual 8...

Page 13: ...LA5034 8 The installation is complete LA5034 User s Manual 9...

Page 14: ...ovide users a simple and full featured interface so that users do not have to spend a lot of time to learn LA5034 provide clock panel waveform panel bus panel measurement panel trigger panel and plug...

Page 15: ...LA5034 Chapter 2 Menu This chapter focuses on the following topics File View Setup Analyzer Help LA5034 User s Manual 11...

Page 16: ...en an exist project z Save Project Save current project to File z Export As CSV File Export data to file as CSV z Export As TXT File Export data to file as TXT z Export As BMP File Export data to file...

Page 17: ...f waveform z Show Trigger Show or hide the trigger line of waveform z Show Mark Show or hide the mark of waveform z Show Measurement Show or hide the measurement of waveform z Zoom In Enlargement wave...

Page 18: ...LA5034 Setup z Signal Name Setup Set the signal name z Bus Setup Configure the bus and signals z Trigger Setup Configure the trigger condition LA5034 User s Manual 14...

Page 19: ...l to trigger position z Scroll to Last Sample Causes the waveform view to roll to the last sample position z Scroll to Mark Causes the waveform view to roll to the mark position z New Mark Create a ne...

Page 20: ...LA5034 Help z Help Content Open the User Manual z About Show the copyright of LA5034 LA5034 User s Manual 16...

Page 21: ...LA5034 Chapter 3 Advanced This chapter focuses on the following topics Clock Panel Bus Panel Waveform Panel Measurement Panel Export Data LA5034 User s Manual 17...

Page 22: ...chosen you can select which clock input will be used for sampling z Trigger Level Configure the input trigger level z Trigger Mode Auto Trigger continuously ignores trigger condition Normal Trigger c...

Page 23: ...CLK A0 A15 B0 B15 You can assign the parts of them to some bus The list box contains all of the bus you can add or delete the bus For example Assign a bus My Bus which has 8 signals ACLK A0 A1 A2 A3 A...

Page 24: ...A3 A4 A5 and A6 if the pane is filled of red is means you have add the signal to the bus 3 Double click the name of the bus which is NewBus1 in this example Then popup an edit box in which you can in...

Page 25: ...LA5034 4 Then Click OK the My bus has been added to the waveform LA5034 User s Manual 21...

Page 26: ...name of the bus with the right mouse button you can configure the bus 1 Display Format The format of the bus data displayed on the waveform 2 Display Order The order of the signals displayed in the li...

Page 27: ...LA5034 5 Show Property Open the bus setup panel Click the waveform with the right mouse button the waveform help menu popup You can operate the LA5034 by the menu LA5034 User s Manual 23...

Page 28: ...the list in the measurement panel Select the Measure combo box You can modify the types of measurement There are 4 types for you such as Interval rate transitions and cycles Click the Delete you can...

Page 29: ...LA5034 Export Data Click the menu File you can export the data to file If you select the CSV file you will export the data as the following LA5034 User s Manual 25...

Page 30: ...LA5034 Chapter 4 Trigger This chapter focuses on the following topics Base Trigger Setup Advance Trigger Setup LA5034 User s Manual 26...

Page 31: ...ata and edge 1 Rising edge Select the Rising edge in the tree select the signal in the combo box Then it will triggered by a rising edge appeared on the selected signal 2 Falling edge Trigger by a fal...

Page 32: ...ger at x time after the appearance of a specified value 6 Data and edge Trigger at the appearance of a specified value on the selected bus and rising falling or rising or falling edge of the selected...

Page 33: ...lick the Advance in the tree then you can configure the advance trigger There are two trigger conditions trigger A and trigger B You can set the trigger mode by clicking the Trigger Mode group box The...

Page 34: ...LA5034 Chapter 5 Plug Manager This chapter focuses on the following topics Summary Example LA5034 User s Manual 30...

Page 35: ...er Plug Manager The list box contains all of the plugs installed in your computer You can add them to waveform by checking them Select a plug and click the Edit button you can modify the property of t...

Page 36: ...r toolbar open the bus setup dialog Then add two buses which only have one signal 2 Open the plug manager and the I2 C setup dialog Click menu dit button Analyzer Plug in Manager then select I2 C and...

Page 37: ...LA5034 4 Select Normal in trigger mode 5 Then you can see the following LA5034 User s Manual 33...

Page 38: ...stable and sensitive I2C signals If there is measuring instrument line interference user can adjust the trigger voltage value Set initial trigger voltage value for SCL and SDA is 1 5V try to adjust th...

Page 39: ...LA5034 Appendix Hardware specification Input connector pin assignments Block Diagram Cleaning and Maintenance LA5034 User s Manual 35...

Page 40: ...nput voltage range 60V 60V Logic threshold Range 6V 6V Max Sample Rate 500 MHz Max input Signal bandwidth 150 MHz Min time resolution 2ns Sample Depth 2KSample Trigger s Max rate 250 MHz Compatible in...

Page 41: ...ow 12 A8 Black Yellow 13 A9 White Yellow 14 A10 Gray Yellow 15 A11 Blue Yellow 16 A12 Green Yellow 17 A13 Yellow Yellow 18 A14 Orange Yellow 19 A15 Red Yellow 20 Ground Black Black Level B Pin Number...

Page 42: ...LA5034 LA5034 User s Manual 38 15 B11 Blue Orange 16 B12 Green Orange 17 B13 Yellow Orange 18 B14 Orange Orange 19 B15 Red Orange 20 Ground Black Black...

Page 43: ...LA5034 Block Diagram LA5034 User s Manual 39...

Page 44: ...se velvet cloth contact the surface of the equipment 2 Pease do not use any corrosive or chemistry Caution Please make sure the equipment is dry enough before going to work Avoid mangling the equipmen...