SCPI Programming Reference
HDG2000 Series Arbitrary Waveform Generator
90
start frequency.
Parameter
Typical Return
1 ms to 300 s, default 1s
+5.00000000000
Set sweep hold time to 5 seconds: SOURce1:SWEep:HTIMe 5
SOURce<n>:SWEep:RTIMe <seconds>|MINimum|MAXimum
SOURce<n>:SWEep:RTIMe ? [MINimum|MAXimum]
Sets number of seconds the sweep takes to return from stop frequency to start frequency.
Parameter
Typical Return
1 ms to 300 s, default 1s
+5.00000000000
Set sweep return time to 5s: SOURce1:SWEep:RTIMe 5
SOURce<n>:SWEep ON|OFF
SOURce<n>:SWEep?
Enables or disables the sweep.
Parameter
Typical Return
ON|OFF, default OFF
ON or OFF
Enable sweep: SOURce1:SWEep ON
SOURce<n>:SWEep:TIME <seconds>|MINimum|MAXimum
SOURce<n>:SWEep:TIME? [MINimum|MAXimum]
Sets time (seconds) to sweep from start frequency to stop frequency.
Parameter
Typical Return
1 ms to 300 s, default 1s
+5.00000000000
Set sweep time to 5s: SOURce1:SWEep:TIME 5
5.2.26 SYSTem Subsystem
The SYSTem subsystem manages instrument state storage, power-down recall, error conditions,
self test, front-panel display control and remote interface configuration.
SYSTem:BEEPer -issues a single beep
SYSTem:BEEPer:STATe -disables or enables beeper
SYSTem:COMMunicate:LAN:GATEway - Set gateway
SYSTem:COMMunicate:LAN:IPADdress - Set IP address
SYSTem:COMMunicate:LAN:MAC - Find MAC address
SYSTem:COMMunicate:LAN:SMASk - Set smask
SYSTem:ERRor? - reads and clears one error from error queue
SYSTem:LANGuage - Select language
SYSTem:KLOCk -
Remote keyboard Lock or unlock keyboard of the front panel
SYSTem:VERSion? -returns version of SCPI used by instrument