Assembly see page 31
English
Symbol description
Do not use silicone containing acetic acid!
Operation
(see page 33)
Maintenance
(see page 34)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Dimensions
(see page 35)
Flow diagram
(see page 35)
Spare parts
(see page 36)
XXX = Colors
000 chrome plated
820 brushed nickel
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
• Safety against backflow
• The product is exclusively designed for drinking water!
Fault
Cause
Remedy
Insufficient water
-
check valve hasn't moved back
-
Exchange check valves
-
Shower filter seal dirty
-
Clean filter seal between shower
and hose
Instantaneous heater didn’t work
-
Flow limiter in handshower isn’t
removed
-
Remove flow limiter
-
Shower filter seal dirty
-
Clean filter seal between shower
and hose
-
check valve hasn't moved back
-
Exchange check valves
Cleaning
(see enclosed brochure)
4
Test certificate
(see page 34)