4
English
Assembly
(see page 35)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Centre distance:
150±12 mm
Connections G 1/2:
cold right - hot left
Thermal disinfection:
70°C / 4 min
• Safety against backflow
• The product is exclusively designed for drinking
water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 40)
To adjust the hot water limiter. Using a hot water limiter in
combination with a continuous flow water heater is not
recommended.
Maintenance
(see page 44)
The check valves must be checked regularly according to
EN 806-5 in accordance with national or regional
regulations (at least once a year).
Dimensions
(see page 38)
Flow diagram
(see page 38)
Spare parts
(see page 42)
XXX = Colors
000 = Chrome Plated
140 = Brushed Bronze
670 = Matt Black
700 = Matt White
Cleaning
(see page 44)
Operation
(see page 41)
Test certificate
(see page 45)
Fault
Cause
Remedy
Insufficient water
- Aerator calcified, dirty
- Clean aerator, replace as necessary
Mixer stiff
- Cartridge defective, calcified
- Exchange cartridge
Mixer dripping
- Cartridge defective
- Exchange cartridge
Hot water temperature too low
- Hot water limiter incorrectly set
- Set hot water limiter
Instantaneous heater didn’t work
- check valve hasn't moved back
- Exchange check valves
- Flow limiter in handshower isn’t
removed
- Remove flow limiter
Summary of Contents for Vivenis 75420 Series
Page 36: ...36 8 SW 3 mm 4 Nm 9a SW 1 5 mm 1 2 11a SW 1 5 mm 1 Nm 1 2 10a 2 min 1 2 7...
Page 37: ...37 SW 2 mm 11b SW 2 mm 2 Nm 1 2 2 min 10b 9b...
Page 46: ...46...
Page 47: ...47...