4
English
Assembly
(see page 33)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
Do not allow the streams of the shower touch sensitive
body parts (such as your eyes). An adequate distance
must be kept between the shower and you.
Shower hoses are only suitable for a connection from
the shower to the fitting. Never fit a shut-off device
between the fitting and the hose.
Intended use of the handle: The handle is not a
medical product, it is not intended for physically
impaired persons, but only for general private use.
Check the proper attachment and tight seating of the
installed products periodically (annually).
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• During installation of the product by qualified trained
personnel, make sure that the entire fastening surface
is even and smooth (no protruding seams or tile
offset), that the finish of the wall is suitable to apply
the product and has no weak points.
• The mesh washer must be insert to protect the shower
against incoming dirt by pipework. Incoming dirt
leads to defects or/and can damage parts of the
shower; such caused faults voids all liability and
guarantee claims.
• For removal of the installed EcoSmart (flow limiter)
from the shower, the pressure must be lower than
0.2 MPa. With a pressure of more than 0.2 MPa, the
EcoSmart must not be removed.
• Optimal functioning is only guaranteed with the
combination of Hansgrohe hand showers and
Hansgrohe shower hoses.
Technical Data
Operating pressure:
max. 0,6 MPa
Recommended operating pressure:
0,15 - 0,4 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Dimensions
(see page 34)
Flow diagram
(see page 35)
Spare parts
(see page 40)
Special accessories
(order as an extra)
• tile-matching-disk Chrome Plated
#96380000 (see page 40)
Cleaning
(see page 39)
Operation
(see page 36)
Test certificate
(see page 40)