4
English
Assembly
(see page 33)
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart
(flow limiter) located behind the aerator can be
removed.
Special information for UK
If installing this product with a pump, please be aware
that it has to have negative head switching. This product
will not function with a positive head pump.
Technical Data
This mixer series-produced with EcoSmart
(flow limiter)
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
70°C / 4 min
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment
(see page 36)
To adjust the hot water limiter. Using a hot water limiter in
combination with a continuous flow water heater is not
recommended.
Dimensions
(see page 39)
Installation example
(see page 38)
Flow diagram
(see page 39)
Spare parts
(see page 42)
XXX = Colors
000 = Chrome Plated
140 = Brushed Bronze
670 = Matt Black
700 = Matt White
Maintenance
(see page 41)
The check valves must be checked regularly according to
EN 806-5 in accordance with national or regional
regulations (at least once a year).
Cleaning
(see page 40)
Operation
(see page 37)
• Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or
after a prolonged period of non-use.
• After periods of prolonged non-use, but at least every
third day, the fittings must be opened with the handle
in hot and cold position to prevent stagnation in the
connecting lines. Let the water run until the water
temperature is constant.
i
Summary of Contents for Tecturis E 150 CoolStart 73053 Series
Page 33: ...33 6 3 4 5 SW 19 mm 4 Nm SW 10 mm SW 3 mm 5 Nm 3 Nm SW 3 mm 1 2 1 1 2 2 Armaturenfett Grease 7...
Page 34: ...34 10 1 2 8 3 Nm 9 61031450 61034450 61025450 61028450 92191000 26x4...
Page 35: ...35 1 2 11 12 SW 2 mm SW 2 mm 2 Nm 13 15 2 min 14...
Page 37: ...37 4 3...
Page 38: ...38 i 61031450 61034450 61025450 61028450...
Page 41: ...41 SW 19 mm 4 Nm SW 10 mm SW 10 mm SW 19 mm 1 2 3 4 5...
Page 43: ...43...