4
Assembly see page 31
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the ixture must be installed, lushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C / 4 min
The product is exclusively designed for drinking water!
English
Symbol description
Cleaning
(see page 40)
Fault
Cause
Remedy
Mixer stif
-
Cartridge defective, calciied
-
Exchange cartridge
Mixer dripping
-
Cartridge defective
-
Exchange cartridge
Hot water temperature too low
-
Hot water limiter incorrectly set
-
Set hot water limiter
-
Crosslow
-
Exchange cartridge
Do not use silicone containing acetic acid!
Adjustment
(see page 33)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous low water heater is not recommended.
Dimensions
(see page 34)
Flow diagram
(see page 35)
free low
Operation
(see page 39)
Spare parts
(see page 36)
XXX =
Colors
000 =
chrome plated
090 =
chrome plated/gold plated
400 =
white/chrome plated
340 =
Brushed Black Chrome
990 =
Polished gold plated
Test certiicate
(see page 48)