Technical Data
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 80°C
Recommended hot water temp.:
65°C
Centre distance:
G ¾
Connections:
cold right - hot left
Rate of flow by 0,3 MPa:
Shower mixer:
32 l/min
Thermostatic mixer:
43 l/min
Thermostatic mixer with shut off unit:
26 l/min
Thermostatic mixer with shut off and diverter unit: 26 l/
min
Thermostatic mixer High Flow:
58 l/min
Bath-shower mixer:
31 l/min // 24 l/min
Installation Instructions
The iBox is suitable for both bath and shower
applications. When using the bath-shower mixer
/ thermostatic mixer with shut off and diverter unit
outlet, the lower outlet must have priority. For shower
applications, plug the unused outlet with a plug.
The hot and cold supplies must be of equal pressures.
Install body with the hot water supply left and cold water
supply right.
extension 25 mm article number 13595000
The installation instructions are primarily concerned with
tap water and Installation. Georg Fischer guarantees the
products and the system if the installation instructions are
followed.
See the attached Installation instructions for Sanipex
Classic.
Installation examples with measurements and pipe
dimensions can be found starting on page 14.
The installation dimensions stated in these installation
instructions are ideal for people of approximately
1800 mm in body height. The dimensions can be
altered if required. In this case, pay attention to the fact
that a change of installation height will also change
the minimum height, and that the altered mounting
dimensions must be taken into consideration.
Flush piping system
To complete the installation flush out both hot and cold
water supply. The arrows on the flush body are showing,
which inlet is connected with which outlet, for example
cold water suply with outlet 1 and hot water supply with
outlet 2. If only one outlet is in use, after first flushing the
flush body must turned about 90º.
English
Assembly see page 34
Warm water
Only one function is possible.
Plug the unused outlet.with plug and nut
(16 mm / 20 mm)
From • the function is guaranteed.
Cold water