4
Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The arm of the shower head is intended only to hold the shower head. Do not
load it down with other objects!
Children as well as adults with physical, mental and/or sensoric impairments
must not use this product without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
The shower system may only be used for bathing, hygienic and body cleaning
purposes.
The hot and cold supplies must be of equal pressures.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the applica-
ble standards.
• The plumbing codes applicable in the respective countries must be oberserved.
• The installation dimensions stated in these installation instructions are ideal for
people of approximately 1800 mm in body height. The dimensions can be
altered if required. In this case, pay attention to the fact that a change of instal-
lation height will also change the minimum height, and that the altered mounting
dimensions must be taken into consideration.
• Where the contractor mounts the product, he should ensure that the entire area of
the wall to which the mounting plate is to be fitted, is flat (no projecting joints or
tiles sticking out), that the structure of the wall is suitable for the installation of the
product and has no weak points. The enclosed screws and dowels are only suit-
able for concrete. For another wall constructions the manufacturer's indications of
the dowel manufacturer have to be taken into account.
• The mesh washer must be insert to protect the overhead shower against incoming
dirt by pipework. Incoming dirt leads to defects or/and can damage parts of the
shower; such caused faults voids all liability and guarantee claims.
• The shower may only be connected downstream of a shut-off valve or sanitary
fitting.
• If required, the bottom part of the pipe between the fixture and the shower head
can be shortened with a fine-toothed saw.
English
Dimensions
(see page 36)
Spare parts
(see page 31)
Symbol description
Special accessories
(order as an extra)
tile-matching-disk chrome plated #98681000
corner fitting set see page 34
Assembly see page 32
Technical Data
Operating pressure:
max. 0,6 MPa
Recommended operating pressure:
0,19 - 0,4 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 60°C
Thermal disinfection:
max. 70°C / 4 min
Safety against backflow
The product is exclusively designed for drinking water!
Do not use silicone containing acetic acid!
Flow diagram
(see page 36)
overhead shower
Hand shower
Cleaning
(see page 38) and enclosed brochure
Operation
(see page 40)
Test certificate
(see page 40)
Summary of Contents for Raindance Showerpipe
Page 32: ...Montage 1 2a 2 1 3 4 5 6 2b SW 8 mm SW 3 mm 6 Nm SW 8 mm SW 3 mm 6 Nm 32 ...
Page 33: ...Montage 9 1 7 SW 8 mm 8 33 ...
Page 34: ...Montage 27158000 1 2 5 4 3 6 7 10 8 SW 8 mm 34 ...
Page 35: ...Montage 2 1 8 9 10 12 13 14 15 16 17 SW 8 mm SW 3 mm 6 Nm SW 3 mm 6 Nm 11 35 ...
Page 38: ...Reinigung 1 5 3 2 1 min 1 4 2 3 SW 5 mm SW 5 mm 2 Nm 1 2 4 2 1 38 ...