Hans Grohe Raindance Showerpipe 180 Reno 27210000 Instructions For Use/Assembly Instructions Download Page 4

3

 

Safety Notes

 

Gloves should be worn during installation to prevent 
crushing and cutting injuries.

 

The arm of the shower head is intended only to hold 
the shower head. Do not load it down with other 
objects!

 

Children as well as adults with physical, mental and/
or sensoric impairments must not use this product 
without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using 
this product.

 

Do not allow the streams of the shower touch sensi-
tive body parts (such as your eyes). An adequate 
distance must be kept between the shower and you.

 

The product may not be used as a holding handle. A 
separate handle must be installed.

 

The shower system may only be used for bathing, 
hygienic and body cleaning purposes.

Installation Instructions

• Prior to installation, inspect the product for transport 

damages. After it has been installed, no transport or 
surface damage will be honoured.

• The pipes and the fixture must be installed, flushed 

and tested as per the applicable standards.

• The plumbing codes applicable in the respective 

countries must be oberserved.

• The installation dimensions stated in these installation 

instructions are ideal for people of approximately 
1700 mm in body height. The dimensions can be al-
tered if required. In this case, pay attention to the fact 
that a change of installation height will also change 
the minimum height, and that the altered mounting 
dimensions must be taken into consideration.

• Where the contractor mounts the product, he should 

ensure that the entire area of the wall to which the 
mounting plate is to be fitted, is flat (no projecting 
joints or tiles sticking out), that the structure of the wall 
is suitable for the installation of the product and has 
no weak points. The enclosed screws and dowels are 
only suitable for concrete. For another wall construc-
tions the manufacturer's indications of the dowel 
manufacturer have to be taken into account.

• The premounted filter insert must be used to ensure 

a normal flow of the shower and to prevent dirt from 
entering through the pipes. Dirt entering can affect the 

English

function and/or lead to damages to the shower. Hans-
grohe will not be held liable for this type of damage.

• The shower may only be connected following (down-

stream from) a shut-off valve of the sanitary fitting.

• If required, the bottom part of the pipe between the 

fixture and the shower head can be shortened with a 
fine-toothed saw.

Technical Data

Operating pressure: 

max. 1 MPa

Recommended operating pressure: 

0,15 - 0,4 MPa

Test pressure: 

1,6 MPa

(1 MPa = 10 bar = 147 PSI)
Hot water temperature: 

60°C

Thermal disinfection: 

max. 70°C / 4 min

• Safety against backflow
• The product is exclusively designed for drinking water!

Symbol description

Do not use silicone containing acetic acid!

Maintenance 

(see page 10)

The check valves must be checked regularly 
according to DIN EN 1717 in accordance 
with national or regional regulations (at least 
once a year).

Dimensions 

(see page 11)

Flow diagram 

(see page 11)

  Hand shower

  overhead shower

Operation 

(see page 8)

To empty the overhead shower after use, 
hold it in a slightly inclined position.

Cleaning / Warranty  

(see page 12)

Spare parts 

(see page 16)

Assembly see page 4

Summary of Contents for Raindance Showerpipe 180 Reno 27210000

Page 1: ...Telefon 04621 30 60 89 0 Mail info unidomo com ffnungszeiten Mo Fr 8 00 17 00 Uhr a member of DAIKIN group Individuelle Beratung Komplettpakete Kostenloser Versand ber 15 Jahre Erfahrung Hochwertige...

Page 2: ...ZH 2 EN Instructions for use assembly instructions 3 Raindance Showerpipe 180 Reno 27210000...

Page 3: ...2 1700 mm 1 MPa 0 15 0 4 MPa 1 6 MPa 1 MPa 10 bar 147 PSI 60 C 70 C 4 10 DIN EN 1717 11 11 8 12 16 4...

Page 4: ...he should ensure that the entire area of the wall to which the mounting plate is to be fitted is flat no projecting joints or tiles sticking out that the structure of the wall is suitable for the inst...

Page 5: ...4 SW 8 mm 1 2 1 2 3 S i l i c o n e 4 1 2 SW 3 mm 5 6 N r 1 0 4 7 6 2 2 0 A r m a t u r e n f e t t G r e a s e 1825 1925 mm...

Page 6: ...5 11 S i l i c o n e 7 9 10 1 2 Nr 10476220 Armaturenfett Grease 8...

Page 7: ...6 SW 3 mm 16 SW 17 mm 10 Nm 97708000 SW 2 mm 1 Nm 12 SW 3 mm SW 8 mm 13 14 15 1 2 SW 3 mm 6 Nm 17...

Page 8: ...7 SW 8 mm 18 19 20 21b 21a 94246000...

Page 9: ...8...

Page 10: ...9 2 3a 3b Croma Select S Multi 26801400 IntenseRain Massage SoftRain 1 2...

Page 11: ...10 1 2 3...

Page 12: ...15 1865 1965 60 80 145 Raindance Showerpipe 27210000 Raindance Showerpipe 27210000 4 5 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 bar 0 45 0 00 0 05 0 10 0 15 0 20 0 25 0 30 0 35 0 40 0 50 0 3 6 9 12 15...

Page 13: ...12 QuickClean QuickClean Hansgrohe Hansgrohe www hansgrohe int com guarantee QUICK CLEAN...

Page 14: ...r use cleaning materials which contain hydrochloric acid formic acid chlorine pale lye or acetic acid as they cause considerable damage Phosphorus acidic cleaners are only conditionally applicable Mix...

Page 15: ...14 Reinigung 1 1 2 4 3 SW 5 mm SW 5 mm 2 Nm 2...

Page 16: ...15 Reinigung 2 3 1 1 min 1 min 94246000 2 1...

Page 17: ...00 28276000 98131000 15x2 5 98214000 12x2 96526000 96044000 98058000 26801400 M6x8 98123000 10x1 5 98131000 15x2 5 98401000 18x2 2 97708000 97536000 97958000 97331000 97552000 97606000 97195000 957650...

Page 18: ...17...

Page 19: ...18...

Page 20: ...19...

Page 21: ...20 Hansgrohe Auestra e 5 9 D 77761 Schiltach Telefon 49 0 78 36 51 1282 Telefax 49 0 7836 511440 E Mail info hansgrohe com Internet www hansgrohe com 03 2016 9 01451 07...