SafetyNotes
Glovesshouldbewornduringinstallationtopreventcrushingandcutting
injuries.
Thearmoftheshowerheadisintendedonlytoholdtheshowerhead.Donot
loaditdownwithotherobjects!
Theshowersystemmayonlybeusedforbathing,hygienicandbodycleaning
purposes.
Childrenaswellasadultswithphysical,mentaland/orsensoricimpairments
mustnotusethisproductwithoutpropersupervision.Personsundertheinflu-
enceofalcoholordrugsareprohibitedfromusingthisproduct.
Donotallowthestreamsoftheshowertouchsensitivebodyparts(suchasyour
eyes).Anadequatedistancemustbekeptbetweentheshowerandyou.
Theproductmaynotbeusedasaholdinghandle.Aseparatehandlemustbe
installed.
Thehotandcoldsuppliesmustbeofequalpressures.
InstallationInstructions
•Priortoinstallation,inspecttheproductfortransportdamages.Afterithasbeen
installed,notransportorsurfacedamagewillbehonoured.
•Thepipesandthefixturemustbeinstalled,flushedandtestedaspertheapplica-
blestandards.
•Theplumbingcodesapplicableintherespectivecountriesmustbeoberserved.
•Theinstallationdimensionsstatedintheseinstallationinstructionsareidealfor
peopleofapproximately1800mminbodyheight.Thedimensionscanbe
alteredifrequired.Inthiscase,payattentiontothefactthatachangeofinstal-
lationheightwillalsochangetheminimumheight,andthatthealteredmounting
dimensionsmustbetakenintoconsideration.
•Wherethecontractormountstheproduct,heshouldensurethattheentireareaof
thewalltowhichthemountingplateistobefitted,isflat(noprojectingjointsor
tilesstickingout),thatthestructureofthewallissuitablefortheinstallationofthe
productandhasnoweakpoints.Theenclosedscrewsanddowelsareonlysuit-
ableforconcrete.Foranotherwallconstructionsthemanufacturer'sindicationsof
thedowelmanufacturerhavetobetakenintoaccount.
•Thefilterinsertmustbeusetoprotecttheshoweragainstincomingdirtbypipe-
work.Incomingdirtleadstodefectsor/andcandamagepartsoftheshower;
suchcausedfaultsvoidsallliabilityandguaranteeclaims.
•Theproductisnotdesignedtobeusedwithsteambaths!
•Ifthewaterconnectionsarenotstabilmounted,thefittingmustbefixedwithextra
screws(seepage31,fig.A1-A11).Withthistypeofinstallation,takecarenot
topuncturethewaterpipe!Ifthewaterconnectionsarestabilmounted,noextra
screwsarerequired(seepage32,fig.B1-B11).
SpecialinformationforUK
Ifinstallingthisproductwithapump,pleasebeawarethatithastohavenegative
headswitching.Thisproductwillnotfunctionwithapositiveheadpump.
TechnicalData
Operatingpressure:
max.1MPa
27126000/27126400Recommendedoperatingpressure:
0,15-0,5MPa
27127000/27127400Recommendedoperatingpressure:
0,2-0,5MPa
Testpressure:
1,6MPa
(1MPa=10bar=147PSI)
Hotwatertemperature:
max.80°C
Assemblyseepage32
Fault
Cause
Remedy
Insufficientwater
-
Supplypressureinadequate
-
Checkwaterpressure(Ifapumphasbeeninstalled
checktoseeifthepumpisworking).
-
Regulatorfilterdirty
-
CleanfilterinfrontofthemixerandontheMTC-
thermocartridge
-
filterinsertshowerdirty
-
Cleanfilterinsertbetweenshowerandhose
Crossflow,hotwaterbeingforcedintocoldwaterpipe,
orviceversa,whenmixerisclosed
-
Backflowpreventersdirtyorleaking
-
Cleanbackflowpreventers,exchangeifnecessary
Spouttemperaturedoesnotcorrespondwithtempera-
tureset
-
Thermostathasnotbeenadjusted
-
Adjustthermostat
-
Hotwatertemperaturetoolow
-
Increasehotwatertemperatureto42ºCto65ºC
Temperatureregulationnotpossible
-
thermocartridgecalcified
-
Exchangethermocartridge
Instantaneousheaterdidn'tworkwiththermostat
-
Filtersaredirty
-
Cleanthefilter/exchangefilter
-
checkvalvehasn'tmovedback
-
Exchangecheckvalves
Cleaning
(seepage44)andenclosedbrochure
Operation
(seepage41)
Toemptytheoverheadshowerafteruse,holditinaslightlyinclined
position.
Flowdiagram
(seepage38)
overheadshowerRain/RainAir
Handshower
overheadshowerStream
overheadshoStream/Stream
Dimensions
(seepage38)
Maintenance
(seepage37)
ThecheckvalvesmustbecheckedregularlyaccordingtoDINEN
1717inaccordancewithnationalorregionalregulations(atleastonce
ayear).Toguaranteethesmoothrunningofthethermostat,itisneces-
saryfromtimetotimetoturnthethermostatfromtotalhottototalcold.
Adjustment
(seepage35)
Aftertheinstallation,theoutputtemperatureofthethermostatmustbe
checked.Acorrectionisnecessaryifthetemperaturemeasuredatthe
outputdiffersfromthetemperaturesetonthethermostat.
SafetyFunction
(seepage36)
Thedesiredmaximumtemperatureforexamplemax.42ºCcanbepre-
setthankstothesafetyfunction.
Donotusesiliconecontainingaceticacid!
Symboldescription
Recommendedhotwatertemp.:
65°C
Centredistance:
150±12mm
ConnectionsG1/2:
coldright-hotleft
Thermaldisinfection:
max.70°C/4min
Safetyagainstbackflow
Theproductisexclusivelydesignedfordrinkingwater!
English
Spareparts
(seepage42)
Specialaccessories
(orderasanextra)
tile-matching-diskchromeplated#95163000
Dismounting
(seepage45)
4
Testcertificate
(seepage48)
Summary of Contents for Raindance Select 2jet Showerpipe 27126000
Page 35: ...35 Justierung 40 C 26 1 2 3 4 5 40 C Silicone 25...
Page 36: ...36 Safety Function Safety Function 1 z B 42 C for example 42 C 2 3 2 1 5 6 7 8 4...
Page 39: ...0 3MPa 386 465 380 630 0 3MPa 386 465 690 Rain RainStream 39...
Page 45: ...Demontage Demontage 3x 3 4 5 6 3x 1 2 45...
Page 46: ...46...
Page 47: ...47...